• Title/Summary/Keyword: drop system

Search Result 1,901, Processing Time 0.035 seconds

Influence of Longitudinal Arch of Foot on the Strength and Muscle Activity of the Abductor Hallucis in Subjects with and without Navicular Drop Sign

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.222-227
    • /
    • 2019
  • Purpose: This study examined the influence of longitudinal arch on the strength and muscle activity of the abductor hallucis in the standing position in subjects with and without navicular drop signs. Methods: A sample of 34 subjects with and without navicular drop signs between 22 and 28 years of age were enrolled in this study. The strength and muscle activity of the abductor hallucis was measured using a tensiometer. The Smart KEMA System and electromyography device was used on the subjects with and without navicular drop signs. Two groups were classified using the navicular drop test to identify the longitudinal arch of the foot. The strength of the abductor hallucis was evaluated in standing, both with and without an external arch support condition. The two-way mixed ANOVA was used. The level of statistical significance was set to ${\alpha}=0.05$. Results: The strength and muscle activity of the abductor hallucis in standing was significantly higher with external arch support than that without the external arch support in the group with navicular drop signs. There was no significant difference in the abductor hallucis strength and muscle activity with and without external arch support in the subjects without navicular drop signs. Conclusions: The strength and muscle activity of the abductor hallucis in standing can be influenced by the external arch support in the group with navicular drop signs. The strength measurement of the abductor hallucis in standing should be separately performed in conditions with and without longitudinal arch of foot.

A Experimental Study of Optimum Filter System Design of High Purity Polymer Thread Machine (고순도 Polymer 방사기계 필터 시스템 최적설계 기술 개발에 관한 실험적 연구)

  • Oh, T.H.;Kim, C.S.;Song, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.514-519
    • /
    • 2000
  • Predicting a pressure drop between inlet and outlet of the filter system is essential in designing the optimum filter system. This experiment has been carried out to investigate several design parameters which influence in a pressure drop, such as different tube length and metal fiber filter mesh size. A 1/50 scale filter system was made to simulate a real filter system. Results are compared with Darcy equation for a porous media.

  • PDF

An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment (주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰)

  • 이상룡;정태식;한기수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

A Study on Sizing System for the Knit Trainning Wears-females from 15 to 24 years old- (니트츄리닝복의 치수 체계에 관한 연구-만 15~24세 여자를 중심으로-)

  • 문명옥;천태일
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.3
    • /
    • pp.335-344
    • /
    • 2000
  • The purpose of this study was to set up sizing system for knit trainning wears. Sample size was 198 females and their age range was from 15 to 24 years old. The body types for sizing system for knit trainning wears were divided by height and drop values. The results were as follows. 1. The height could be divided into three groups and they covered 97.5%. The Short(152cm) covered 27.8%, the Regular(160cm) 51.0% and the Tall(168cm) 18.7%. 2. The Medium hip(drop value 6) and the Large hip(drop value 12)had the high coverage rate of 45.5% and 46%, and the Small hip(drop value 0) had the low coverage rate of 8.6%. 3. For sizing system for knit trainning wears, the intervals of bust girth and hip girth were 5cm and 4cm. In the same size of bust girth, the intervals of hip high girth and waist girth were 1cm, the intervals of back waist length and sleeve length were 2cm and the interval of slacks length was 4∼5cm according to three height groups.

  • PDF

Regenerative Inverter System for DC Traction Substation with Voltage Drop Compensation Mode (전압강하 보상모드를 갖는 직류 지하철용 회생인버터 시스템)

  • Kim, Jun-Gu;Kim, Jae-Hyung;Cho, Kee-Hyun;Won, Chung-Yuen;Kim, Yong-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.213-220
    • /
    • 2008
  • In this paper, the regenerative inverter system with voltage drop compensation mode is proposed. When the main rectifier is broken, the DC traction can not be supplied the power from the utility. Actually, the reserve rectifier is mounted in the substation to prevent this accident. In this paper, the voltage drop compensation mode is added to the regenerative inverter system in order to substitute the reserve rectifier. The proposed regenerative inverter system returns the regenerative energy from the DC line voltage to the utility. In addition, the inverter can be compensate the harmonics caused by the power conversion devices used in the DC traction system. We demonstrated the effectiveness of the proposed control algorithm by using computer simulation.

The Study on embedded components high integrated packaging and drop reliability (부품 내장형 고집적 패키징 및 Drop 신뢰성에 관한 연구)

  • Chung, Yeon-Kyung;Park, Se-Hoon;Ha, Sang-Ok;Jun, Byung-Sub;Cha, Jung-Min;Park, Jong-Chul;Kang, Nam-Kee;Jung, Seung-Boo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.315-315
    • /
    • 2010
  • 휴대용 전자 기기는 얇고 가벼우면서 빠른 대용량을 처리하는 속도와 다기능이 필요한 추세로 가고 있다. 기기 크기가 작아짐에 따라서 내장 되는 칩 또한 소형화, 고집적화, 고성능화가 요구되므로 이에 상응하는 발전된 패키징 기술이 필요하게 되었고, 이에 대응하기위해서 embedded components device 패키징 기술이 필요로 하게 되었다. 본 연구에서는 $21{\Omega}$ 의 저항 값을 갖는 1005 수동 소자를 prepreg를 이용하여 PCB기판에 내장 한 후 micro via를 이용하여 무전해 구리 도금으로 전기적인 연결을 하여 기판을 제작하였다. 제작되어진 기판으로 Reflow, Aging 테스트 후 칩과 계면간의 금속화합물 반응을 관찰하였다. 또한 Reflow외 시효처리를 끝마친 기판을 사용하여 drop test를 실시한 후 fail 발생 시 저항 값의 변화와 접합부의 미세조직을 관찰하였다.

  • PDF

A Study on Sizing System for the Competitive Manufacturing Environment of Domestic Apparel Product -Based on the Outerwear of Men in Their Twenties- (우리 나라 의류제품의 국제경쟁력 제고를 위한 사이즈체계 연구 -20대 남성의류 사이즈를 중심으로-)

  • Lee, Hyoung-Sook;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.397-405
    • /
    • 1999
  • For proper communication among manufacturers in many countries and for consumer's convenience in purchasing garments imported from foreign countries, the ISO revised the size designation system in 1969. Since 1970's many countries have revised their standard sizing system by adopting the ISO system. The purpose of this study is to satisfy domestic consumer's needs by developing a sizing system based on that of ISO for Korean men in their twenties, and to contribute to entering the international fashion market by manufacturing high quality apparel products. The results were as follows: By measuring and analyzing of men in their twenties, average height is 172 cm, average chest girth is 92.8 em, average hip girth is 93.4cm and average drop is 15.8. According to the result to analyzing body type of this study, athletic type(drop 18) is 47.8%, regular type (drop 12) is 37.3%, the 2 types covers 85%.

  • PDF

Greenhouse Cooling by Fog System (FOG SYSTEM 을 이용한 여름철 온실냉방)

  • 서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

Design, Fabrication and Test of the Micro Optical Add/Drop Module Using Silicon Optical Bench and Automatic Optical Fiber/Filter Alignment System (실리콘 광벤치 및 자동 광섬유/필터 정렬시스템을 이용한 극소형 광통신용 Add/Drop 모듈의 설계 제작 및 실험)

  • 최두선;박한수;서영호;김성곤;제태진;황경현
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.211-215
    • /
    • 2004
  • Recently, one of remarkable tends in the development of optical communication industry is the miniaturization and integration of products. The alignment system of micro optical module is a key apparatus for the miniaturization of optical module and the development of optical communication parts with high functionality. In this research, we have developed a system capable of automatic alignment of a $30\mu\textrm{m}$-thick film filter and a lensed fiber in order to improve the speed and losses in the optical fiber-to-filter alignment of optical modules. Using the developed automatic alignment system and silicon optical bench, we have measured optical loss and characteristics of the assembled optical add/drop module before packaging $1{\times}1$ OADM optical module. Whole size of add/drop module was less than $5mm{\times}5mm{\times}1mm$. The measured maximum insertion loss was 0.294㏈ that is below 0.3㏈ which is a standard loss of optical module.

A-Study on The Heat Transfer Performance of Evaporator Heat Transfer Tube for Absorption Chiller (흡수식 냉온수기 증발기용 전열관의 전열성능에 관한 연구)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho;Kim, Hyo-Sang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.215-221
    • /
    • 2009
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer coefficient of thermoexcel notch tube increases about 79.6% and 45.3% at the film Reynolds number 69.7 compared with that of bare tube and low fin tube, respectively. The thermoexcel notch tube is show the best performance considering pressure drop and heat transfer coefficient.