• 제목/요약/키워드: droop

검색결과 204건 처리시간 0.034초

Convex Optimization Approach to Multi-Level Modulation for Dimmable Visible Light Communications under LED Efficiency Droop

  • Lee, Sang Hyun;Park, Il-Kyu;Kwon, Jae Kyun
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.29-35
    • /
    • 2016
  • This paper deals with a design method and capacity loss of an efficient multi-level modulation scheme for dimmable visible light communications (VLC) systems that use light-emitting diodes (LEDs) with efficiency droop. To this end, the impact of such an impairment on dimmable VLC is addressed with respect to multi-level modulations based on pulse-amplitude modulation (PAM) via data-rate optimization formulation.

SOC 상태에 따른 가변 droop 제어를 적용한 주파수 조정용 에너지 저장장치의 최적운영에 관한 연구 (A study on Optimal Operation of Energy Storage System for Frequency Regulation Using the Variable Droop Control Based on the Status of SOC)

  • 이용승;김욱원;김동민;배인수;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.625-626
    • /
    • 2015
  • 본 논문에서는 주파수 조정용으로 에너지 저장장치를 활용하기 위해 SOC(State Of Charge) 상태에 따른 가변Droop계수를 적용하여 주파수를 회복하기 위해 SOC 목표 값 과 그에 따른 주파수 변화량을 계산해 최적 SOC 목표 값을 찾는 방법을 제안한다.

  • PDF

정적 처짐을 고려한 초장축 스핀들의 동적시뮬레이션 (An Active Simulation of Long Spindle with Static Droop)

  • 정원지;이춘만;박기범;김재실
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.451-452
    • /
    • 2006
  • According to the demand of high productivity, the interest of manufacturing skills is growing in the industrial society. Especially the long spindle becomes important these days. The rotating accuracy of the spindle concerns the centrifugal force. In detail explaining, it is influenced by the speed of the spindle. In this study, we would show changes of the distance caused by a rotating speed of the spindle using a software, $ADAMS^{(R)}$. And because of the gravity of the spindle's mass, we would find the static droop of the long spindle.

  • PDF

Double-Sharpened Decimation Filter Employing a Pre-droop Compensator for Multistandard Wireless Applications

  • Jeong, Chan-Yong;Min, Young-Jae;Kim, Soo-Won
    • ETRI Journal
    • /
    • 제33권2호
    • /
    • pp.169-175
    • /
    • 2011
  • This paper presents a double-sharpened decimation filter based on the application of a Kaiser and Hamming sharpening technique for multistandard wireless systems. The proposed double-sharpened decimation filter uses a pre-droop compensator which improves the passband response of a conventional cascaded integrator-comb filter so that it provides an efficient sharpening performance at half-speed with comparison to conventional sharpened filters. In this paper, the passband droop characteristics with compensation provides -1.6 dB for 1.25 MHz, -1.4 dB for 2.5 MHz, -1.3 dB for 5 MHz, and -1.0 dB for 10 MHz bandwidths, respectively. These results demonstrate that the proposed double-sharpened decimation filter is suitable for multistandard wireless applications.

분산전원과 에너지저장으로 구성된 독립형 DC 마이크로그리드의 협조적 Droop 제어 기법 (Coordinated Droop Control Method for Stand-alone Type DC Micro-grid with Distributed Sources and Energy Storage)

  • 이지헌;김현준;한태희;박아련;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.240-241
    • /
    • 2012
  • 본 연구에서는 분산전원과 에너지저장으로 구성된 독립형 DC 마이크로그리드의 신뢰도를 향상시키기 위한 협조적 Droop 제어기법을 제안하고 그 성능과 동작을 분석한 내용에 대해 기술하고 있다. 제안하는 시스템의 동작 타당성을 체계적으로 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용한 시뮬레이션 모델을 개발하였으며 이를 기반으로 하드웨어 시스템을 제작하여 제안하는 시스템의 동작특성을 분석하였다.

  • PDF

Accurate Power Sharing in Proportion for Parallel Connected Inverters by Reconstructing Inverter Output Impedance

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1751-1759
    • /
    • 2018
  • This paper presents parallel-connected inverters to achieve accurate proportional power sharing. Due to line impedance mismatch, reactive power cannot be distributed proportionally when using the conventional $P-{\omega}$ and $\mathcal{Q}-E$ droop. In order to realize reactive proportional power sharing, the ratio of the droop coefficients should be inversely proportional to their power-sharing ratios. Meanwhile, the ratio of the line impedance should be inversely proportional to the desired power-sharing ratio, which is very difficult to be met in practice. In order to deal with this issue, a practical control strategy is presented. By measuring the PCC voltage and using the virtual impedance, the output impedance of individual inverters is reconstructed to counteract the line impedance effect. In order to guarantee system stability, a low pass filter is designed to suppress the bandwidth of the line compensation. Finally, the simulation and experimental results are given to verify the effectiveness of the proposed control strategy.

직류급전 시스템의 Autonomous Operation을 위한 교류연계장치와 에너지 저장의 Droop Control (A Droop Control for the Autonomous Operation of DC Distribution System using Grid-tied Converter and Energy Storage)

  • 이지헌;차민영;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.32-33
    • /
    • 2010
  • This paper describes a droop control method for the autonomous operation of DC distribution system using distributed generations and energy storage. The method suppress the circulating current, and each unit could be controlled autonomously without communication system. Detailed model of wind power generation, photo-voltaic generation, fuel-cell generation and battery was implemented with the user-defined model of PSCAD/EMTDC software that is coded with C-language. The simulation and experimental results confirms that the proposed DC distribution system make it feasible to provide power to the load stably and verify effectiveness of the proposed method.

  • PDF

Control Strategy for Accurate Reactive Power Sharing in Islanded Microgrids

  • Pham, Xuan Hoa Thi;Le, Toi Thanh
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1020-1033
    • /
    • 2019
  • This paper presents a control strategy to enhance the accuracy of reactive power sharing between paralleled three-phase inverters in an islanded microgrid. In this study, the mismatch of power sharing when the line impedances have significant differences between inverters connected to a microgrid has been solved, the accuracy of the reactive power sharing in an islanded microgrid is increased, the voltage droop slope is tuned to compensate for the mismatch of voltage drops across the line impedances by using an enhanced droop controller. The proposed method ensures accurate power sharing even if the microgrid has local loads at the output of the inverters. The control model has been simulated by MATLAB/Simulink with two or three inverters connected in parallel. Simulation results demonstrate the accuracy of the implemented control method. Furthermore, in order to validate the theoretical analysis and simulation results, an experimental setup was built in the laboratory. Results obtained from the experimental setup verify the effectiveness of the proposed method.

Droop 제어 기반 계통연계 병렬인버터의 끊김없는 모드전환기법 (A Seamless Mode Transfer Method of Droop Control based Grid-connected Parallel Inverters)

  • 박성열;강수한;정호영;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.26-28
    • /
    • 2019
  • 중요부하를 가지고 있는 계통연계 병렬인버터는 계통과의 연결이 끊길 경우 중요부하에 안정적인 전압공급을 위하여 끊김 없는 모드전환 동작이 요구된다. 기존 병렬인버터는 계통연계 시 전류제어모드 운전을 하고, 독립운전 시에는 전압제어모드 운전을 한다. 그래서 단독운전 발생 시 불안정한 전압을 부하에 공급하게 되고, 모드전환 시 제어기절체로 인해 인버터출력전압에 심각한 과도상태를 발생시켜 중요부하에 큰 손상을 입힐 수 있다. 본 논문에서는 Droop 제어 기반 계통연계 병렬인버터의 끊김 없는 모드전환 기법을 제안한다. 제안된 알고리즘은 1kW 시작품을 제작하여 타당성을 검증하였다.

  • PDF

철도 차량용 보조전원장치의 병렬 운전을 위한 가상 임피던스 기반의 드룹 제어 (A Modified Droop Control Method for Parallel Operation in Railway Auxiliary Power Supply Based on Virtual Impedance)

  • 안창균;최봉연;강진욱;강경민;이훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.342-343
    • /
    • 2019
  • This paper explores the power distribution problem of parallel-connected inverter system which supplies auxiliary power for railway facilities. We propose a droop control method which facilities power distribution and restrain of voltage drop by tracking the average power control command by adjusting the virtual impedance. The performance of proposed droop method is verified by the PSIM simulation.

  • PDF