• Title/Summary/Keyword: drinking water standard

Search Result 250, Processing Time 0.02 seconds

Comparison of Water Quality Between Private and Simple-Piped Drinking Water Supply in Rural Community (농촌지역 개인소유 음용수와 간이상수도의 수질에 대한 비교 연구)

  • 이진헌;이인숙
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.1
    • /
    • pp.54-61
    • /
    • 1994
  • This study was carried out to investigate the degree of contamination in private-drinking water supply (PDWS) and simple-piped water supply (SPWS), and to compare of water quality between them for 3 years from 1990 to 1992. The results of the study were as follows: 1. Private-drinking water supply (PDWS) (1) Field-Site (ㄱ) The items which were very significantly over the criteria (p<0.01), were temp., pH, NO-N, standard plate count (S.P.C.) and Coliform. (ㄴ) No. of households which were over the criteria, were 11.2~51.7% in temp., pH, NH$_3$-N and NO$_2$-N, and 83.1~93.3% in NO-N, S.P.C. and Coliform. (2) Moutain-Site (ㄱ) The items which were over the criteria, were NO$_2$-N (p<0.05), S.P.C. (p<0.01) and Coliform (p<0.01). (ㄴ) No. of households which were over the criteria, were 33.6 ~ 75.6% in NO$_2$-N, S.P.C. and Coliform. (3) No. of households which were fit to the criteria of all items, were 9.0% in field-site and 14.1% in mountain-site. 2. Simple-piped water supply (SPWS) (1) The items which were very significantly over the critera (p<0.01), were standard plate count (S.P.C.) and Coliform. (2) The water qualities of adjacent and remote samples were better than those of source samples. (3) Residual chloride was not detected in any sample. In conclusion, rural community requires to be continually performed the policy of safety drinking water supply, and to be devised an epoch-making counterplan for the level-up of simple-piped water supply (SPWS), espically on the method of disinfection.

  • PDF

Assessment of Water Quality in Paldang-dam Surface Area through the Estimation of Volcanic Ash Toxic Components from Mt. Baekdu (백두산 화산재 유해성분 추정을 통한 팔당댐 유역 수질영향 평가)

  • Jee, Yong Keum;Lee, Gyeng Bin;Choi, Jung Ryel;Kim, Ji Tae
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.3
    • /
    • pp.237-245
    • /
    • 2014
  • Volcanic ash components of Mt. Baekdu were estimated to response the change of water quality environment affected by Mt. Baekdu volcanic ash ejected during eruption. Then the change of water concentrations according to the sedimentation of volcanic ash components were analysed. To estimate volcanic ash components of Mt. Baekdu, similar volcanos were selected through the comparison of main foreign volcano's magma type and the selected volcanic ash components supposed as Baekdu Mountain's. To analyse the change of water concentrations, the change of harmful components affected by volcanic ash sedimentation were analysed and the results were compared with domestic drinking water quality standard. As the result, Al, Cd, F, Fe, Pb, Mg, Cl and Sr could affect to water quality. Among those components, concentrations of Cd, F, Fe, Pb and Mg were estimated to exceed the drinking water quality standard.

A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant (시흥정수장 막여과시설 시범운영)

  • 김한승;김충환;김학철;윤재경;안효원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

Analysis of Haloacetonitriles in Drinking Water Using Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HANs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.628-637
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of disinfection by-products (DBPs) such as haloacetonitriles (HANs), trihalomethanes (THMs), haloacetic acids (HAAs). In this study, headspace-solid phase microextraction (HS- SPME) technique was applied for the analysis of HANs in drinking water. The effects of experimental parameters such as selection of SPME fiber, the addition of salts, magnetic stirring, extraction temperature, extraction time and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and detection limits were also evaluated. The $50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were the optimal experimental conditions for the analysis of HANs. The correlation coefficients ($r^2$) for HANs was 0.9979~0.9991, respectively. The relative standard deviations (%RSD) for HANs was 2.3~7.6%, respectively. Detection limits (LDs) for HANs was $0.01{\sim}0.5{\mu}g/L$, respectively.

Performance of membrane filtration in the removal of iron and manganese from Malaysia's groundwater

  • Kasim, Norherdawati;Mohammad, Abdul Wahab;Abdullah, Siti Rozaimah Sheikh
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.277-296
    • /
    • 2016
  • The aim of this research was to investigate the ability of nanofiltration (NF) and ultrafiltration (UF) membranes as a filtration unit for groundwater treatment for drinking water resources. Commercial membranes denoted as TS40, TFC-SR3 and GHSP were used to study the performance based on rejections and fluxes. The investigation has been conducted using natural groundwater obtained from a deep tube well with initial concentration of iron (Fe) and manganese (Mn) at 7.15 mg/L and 0.87 mg/L, respectively. Experimental results showed that NF membranes exhibited higher fluxes than UF membrane with pure water permeability at 4.68, 3.99 and $3.15L.m^{-2}.h^{-1}.bar^{-1}$, respectively. For metal rejection, these membranes have performed higher removal on Fe with TS40, TFC-SR3 and GHSP membranes having more than 82%, 92% and 86% respectively. Whereas, removal on Mn only achieved up to 60%, 80% and 30%, for TS40, TFC-SR3 and GHSP membranes respectively. In order to achieve drinking water standard, the membranes were efficient in removing Fe ion at 1 and 2 bar in contrast with Mn ion at 4 and 5 bar. Higher rejection of Fe and Mn were achieved when pH of feed solution was increased to more than 7 as TFC-SR3 membrane was negatively charged in basic solution. This effect could be attributed to the electrostatic effect interaction between membrane material and rejected ions. In conclusion, this study proved that NF membrane especially the TFC-SR3 membrane successfully treated local groundwater sources for public drinking water supply in line with the WHO standard.

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

Status of Drinking Water in Pproyap and Langthle, Cambodia (캄보디아 쁘로얍 지역과 랭뜰 지역 거주민의 먹는물 현황)

  • Kim, Younkwon;Kim, Sungpil;Chae, Seonha
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.5
    • /
    • pp.357-368
    • /
    • 2016
  • Cambodia is the representative of developing country in Southeast Asia region. As a view point of water resource, Cambodia has in abundance but public sanitation problems persist in rural areas due to unsafe drinking water and untreated human waste. The purpose of this research is to prepare and develop new strategies for the water aid program in Cambodia by assessing, reviewing, and analyzing the present situation of water pollution for rural areas and the existing water use cycle in these regions. Pproyap and Langthle regions in Pursat province are selected as research areas. Cambodian's rural population in research areas relies on surface water stored in drinking-detention swamps, rain-water jars, and unprotected wells. The two types of main measures, thermotolerant coliform(TTC) bacteria and general pollutants, were conducted to assess the quality of selected water samples for research areas. TTC is a bacterial indicator of waterborne fecal contamination. For the 26 water samples, only one of the samples met the WHO standard for safe drinking water of 0 TTC colony forming units/100 mL.

A Comparative study on drinking Water quality of simple piped Water supply Systems and water Pumps. (일부 농촌 지역의 간이 상수도와 Pump수의 수질에 관한 비교 연구조사 -춘성군 지역을 중심으로-)

  • 정문호;송금순
    • Journal of Environmental Health Sciences
    • /
    • v.9 no.1
    • /
    • pp.77-84
    • /
    • 1983
  • A study was carried out to find drinking water qualities of 56 simple piped water supply systems and 37 water pumps in Chun Sung Conutry, Kang Won Province from 1st July to 30th August 1981. 1. The results of all kinds of water test are found to be safe at only one out of fifty six samples of simple piped water supply system at two out of thirty-seven samples of water pump and unsafe at the others. 2. In general Count of Bacteria test, twelve (21.4%) out of fifty six samples of the simple piped water are found to be safe for the legitimate standard of safty water, and five (13.5%) out of thirty=seven samples of pump water. 3. Escherichia coli group is negative at seven (12.5%) out of fifty-six samples of simple piped water, and eight (21.6%) out of thirty-seven samples of pump water. 4. The results of the physical and chemical examination of drinking water specimen are found to be safe at twelve out of fifty-six samples of simple piped water and at twenty-eight out of thirty-seven samples of pump water.

  • PDF

A Study on Fluoride Content in the Reservoirs Of Iksan Region (익산지역 수원지의 불소함량에 관한 조사연구)

  • Lee, In-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.139-143
    • /
    • 1998
  • This study was carried out to collect basic dates on fluoride intake from drinking water, and the apperance of mottled teeth after taking samples form 5 selected waterways from Iksan region's reservoir to the filtration plant for examination of the fluoride content. The results are as follows. 1. It indicatied that from Hoojung reservoir $2.17{\pm}0.95ppm$, Bulsan reservoir $1.93{\pm}0.23ppm$ and Yoolso reservoir $2.19{\pm}0.10ppm$. 2. Significances were found between Shinhung reservoir $2.57{\pm}1.22ppm$ and Uhwoo reservoir $0.80{\pm}0.55ppm$. 3. Except for the Uhwoo reservoir, the remaining 4 reservoir exceeded the standard fluoride content of 0.50-1.00ppm. For the residents in the region where they use natural water with fluoride content exceeding the standard 1.00ppm as their drinking water and the apperance of mottled teeth should be carried out.

  • PDF

Perchlorate in Advanced Drinking Water Treatment Process (고도정수처리 과정에서 퍼클로레이트 이온의 농도 변화)

  • Kim, Hyun-koo;Kim, Joung-hwa;Lee, Youn-hee;Lee, Jae-ho;Kim, San
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.164-168
    • /
    • 2008
  • Perchlorate, which is still unregulated, is found in tap water, posing a threat to public health. In and out of Korea, there is no clear standard for drinking water quality or discharge. To make matters worse, Perchlorate study is in its infancy in Korea. This research tracked fresh water and purified water of water purification facility A and B located at the city of D, where Nak-dong River is being utilized as the purified water. And it was found that purified water shows no particular pattern in Perchlorate concentrations but represented a higher level of concentration compared to fresh water. With utilizing the research results, the study sought the impact of activated-carbon treatment process on Perchlorate elimination and found out that Perchlorate concentrations increased 38% after the process. The result proves that conventional water purification process can't eliminate Perchlorate. Therefore, it is reasonable that Perchlorate discharge from sources should be minimized.