• Title/Summary/Keyword: drinking groundwater

Search Result 237, Processing Time 0.021 seconds

Removal of Dissolved Iron in Groundwater by Injection-and-Pumping Technique: Application of Reactive Transport Modeling (주입-양수 기법을 활용한 지하수 내 용존 철 제거: 반응성용질이동모델링의 적용)

  • Choi, Byoung-Young;Yun, Seong-Taek;Kim, Kyoung-Ho;Koh, Yong-Kwon;Kim, Kang-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.29-37
    • /
    • 2007
  • Shallow alluvial groundwaters in Korea of tell exceed the Korean Drinking Water Standard for dissolved iron (0.3 mg/L), which is one of the important water quality problems, especially in the use of bank infiltration technique. Using the reactive transport modeling, in this study we simulated the effectiveness of injection-and-pumping technique to remove dissolved iron in groundwater. The results of simulation showed that pumping of groundwater after injection of oxygenated water into aquifers is very effective to acquire the permissible water quality level. Groundwater withdrawal up to several times of irjected water in volume can be applicable to yield drinkable water. Potential problems such as clogging and permeability lowering due to in-situ precipitation of iron hydroxides may be insignificant. We also discuss on the mechanism and spatial extent of iron removal in aquifer.

Evaluation of Groundwater Quality Using Factor Aanlyses and Agrochemicals in an Agricultural Area (요인분석과 농약성분 특성에 의한 농업지역의 지하수 수질 평가)

  • Lee, Jeong-Hwan;Hamm, Se-Yeong;Kim, Kwang-Sung;Cheong, Jae-Yeol;Ryu, Sang-Min;Kim, Deuk-Ho;Kim, Hyun-Ji
    • Economic and Environmental Geology
    • /
    • v.42 no.3
    • /
    • pp.217-234
    • /
    • 2009
  • This study characterized groundwater quality and the influence of agrochemicals in a part of Ilgwang-Myeon agricultural area in Gijang-Gun, Busan Metropolitan City, using factor analyses. From the 1st, 2nd, and 3rd analyses of groundwater samples, the mean concentrations of $Ca^{2+}$, $Na^+$, $Mg^{2+}$, $K^+$, $Zn^{2+}$, $Cu^{2+}$, $Fe^{2+}$, $Al^{3+}$, $NO_3\;^-$, $Cl^-$, $SO_4\;^{2-}$, $F^-$, and $SiO_2$ were higher in the 2nd analysis than the other analyses. Pesticide carbofuran and herbicide alachlor were detected at the wells more than a half of all the wells in the 2nd analysis but not in the 4th analysis. This fact may be explained by that a higher precipitation induced higher infiltration rate of contaminants into groundwater during the 2nd survey. According to R- and Q-mode factor analyses, and chemical composition, inorganic constituents excepting $SiO_2$, $HC0_3\;^-$-, and $F^-$ may be influenced by anthropogenic sources (manures, synthetic fertilizers, and domestic wastes), seawater as well as water-mineral interaction. A typical indicator of groundwater contamination, nitrate, exceeds around 4-5 times over the Korean standard for drinking water. Additionally, the influence of seawater diminishes from the seaside to inland.

The Study on Constructing Underground Wall to Prevent Seawater Intrusion on Coastal Areas (지하수댐 물막이벽 시공법과 해안지역 염수침입 방지기술 개선 방안)

  • 부성안;이기철;김진성;정교철;고양수
    • The Journal of Engineering Geology
    • /
    • v.12 no.2
    • /
    • pp.215-234
    • /
    • 2002
  • Groundwater Dam is one of the reliable techniques to get huge amount of groundwater abstraction for municipal, agricultural, drinking, industrial water supply system. It can be a major technique to solve water shortage problems when it based on the sufficient watershed, proper topology, and adequate aquifer distribution and pollution control, Groundwater Dam had initiated its construction by RDC(former KARICO) in early eighties in Korea and 4 of it in total were added more until late eighty. However, this technique has shrunken its application due to gradually decreased yield rate after sever years of construction. After we studied several existing sites precisely, we concluded that the main reason of decreasing yield rate was come form engineering roughness on construction in early nineties. Theoretically, the technique itself seemed to be little detectives however, there were a little application in the fields in Korea. With the recent advance in engineering fields, those defects in construction would be no longer obstacle to construct underground wall and the technique could be a one of major ground water production technique in the future. It is essential to study following items thoroughly before select the appropriate site. The topography and the site of the underground wall, aquifer distribution, the specific technique for wall construction to block groundwater flow effectively and strict quality control during construction are critical. The surface and ground water monitoring data should be collected. Sustainability of the Groundwater Dam with huge groundwater abstraction in long term should be based on the long-term water balance analysis for each site. The water quality, environmental effect analysis and maintenance achedule should be also analyzed and planned in prior. It is suggested that the two consecutive underground wall in the coastal area to prevent seawater intrusion beneath a single wall.

Analysis on the contamination and source of VOCs in groundwaters of Gwangju area (광주광역시의 지하수 중 휘발성유기화합물(VOCs)의 오염과 오염원 분석)

  • Yun, Uk;Cho, Byong-Wook;Eum, Chul-Hun;Sung, Ik-Hwan
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.389-404
    • /
    • 2003
  • VOCs were detected in the 21 groundwaters out of 37 groundwaters sampled from around the Hanam Industrial Complex and the Gwangju stream. Ten components of chlorinated aliphatic hydrocarbons of VOCs were detected in the 18 groundwater samples. Among them, total trihalomethanes (TTHM) concentration is in the range of $0.1~36.2{\;}\mu\textrm{g}/L$, CECs concentration is $2.3~190{\;}\mu\textrm{g}/L$, and chlorinated solvents concentration containing PCE, TCE, etc. is $0.1~124.2{\;}\mu\textrm{g}/L$ respectively. Ten components of the aromatic hydrocarbons of VOCs were detected in the 5 groundwater samples, but their concentration are less than $1{\;}\mu\textrm{g}/L$. Detection frequency and concentration of the chlorinated aliphatic hydrocarbons components from the groundwaters in the Hanam Industrial Complex are higher than those of nearby downtown Gwangju stream. VOCs components except for TCE are lower than the MCL of USGS drinking water standard. TCE concentration of the 2 groundwater samples is over MCL, whose concentrations are 5 and 25 times higher than MCL, respectively. TCE is detected from the H8 and H10 groundwater samples and CFCs is detected H8 and H11 groundwater samples in the Hanam Industrial Complex. TTHM in study area is estimated from leakage of the main waters or sewage waters. Because most of the studied groundwater is under an aerobic condition, aromatic hydrocarbons are well degraded. But chlorinated aliphatic hydrocarbons are degraded very slowly.

A Study on the Recharge Characteristics of Groundwater in the Jeju Samdasoo Watershed Using Stable Water Isotope Data (안정동위원소를 이용한 제주삼다수 유역의 지하수 함양 특성 연구)

  • Shin, Youngsung;Kim, Taehyeong;Moon, Suhyung;Yun, Seong-Taek;Moon, Dukchul;Han, Heejoo;Kang, Kyounggu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.25-36
    • /
    • 2021
  • This study evaluated monthly, seasonal and altitudinal changes of oxygen and hydrogen isotope compositions of wet precipitation samples (n = 238) that were collected for last four years from 7 altitudes (from 265 to 1,500 m above sea level) in the Jeju Samdasoo watershed at the southeastern part of Jeju island, in order to examine the recharge characteristics of groundwater that is pumped out for the production of the Samdasoo drinking mineral water. Precipitation samples showed a clear seasonal change of O-H isotopic composition as follow, due to the different air masses and relative humidity: 𝛿D = 7.3𝛿18O + 11.3 (R2 = 0.76) in the wet season (June to September), while 𝛿D = 7.9𝛿18O + 9.5 (R2 = 0.91) in the dry season (October to May). In contrast, the stable isotope compositions of groundwater were nearly constant throughout the year and did not show a distinct monthly or seasonal change, implying the well-mixing of infiltrated water during and after its recharge. An altitudinal effect of the oxygen isotope compositions of precipitation was also remarkable with the decrease of -0.19‰ (R2 = 0.91) with the elevation increase by 100 m. Based on the observed altitudinal change, the minimum altitude of groundwater recharge was estimated as 1,200 m above the sea level in the Jeju Samdasoo watershed.

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

Application of Geostatistical Methods for the Analysis of Groundwater Contamination in Pusan (부산지역 지하수 오염현황 분석을 위한 지구통계 기법의 응용)

  • 정상용;강동환;박희영;심병완
    • The Journal of Engineering Geology
    • /
    • v.10 no.3
    • /
    • pp.247-261
    • /
    • 2000
  • The geostatistical analyses for the chemical components of pH, TS, KMnO4 Demand, Cl, SO$_4$ and NO$_3$-N are carried out to understand the groundwater contamination in Pusan. The average values of each component are 7.2 for pH, 336.4mg/$\ell$ for TS, 2.3mg/$\ell$ for KMnO$_4$ Demand, 44.3mg/$\ell$ for Cl, 36.0mg/$\ell$ for SO$_4$, and 4.6mg/$\ell$ for NO$_3$-N. The ratios over the drinking standard of each component are 0.34% for pH, 2.27% for TS, 1.55% for KMnO$_4$ Demand, 1.59% for Cl, 0.57% for SO$_4$, and 3.7% for NO$_3$-N. The highest ratio of NO$_3$-N results from the municipal sewage and exhaust gas of vehicles. The isopleth maps of 6 chemical components show that the high values of groundwater contamination come from the inland of Pusan, and that some high values appear at the coastal area. The isopleth maps of Cl and SO$_4$ related with seawater intrusion also show that the high values appear only at the particular coastal area, not at the whole area. On the isopleth maps of Cl and SO$_4$, the anomalies of the concentration contours were compared with the directions of two large fault zones, the Ilkwang Fault and the Dongrae Fault. Apparently, they don't have the particular correlation. Therefore, it is concluded that the main source of groundwater contamination in Pusan is not the seawater, but the municipal sewage and other sources such as the exhaust gas of vehicles, the contaminated surface water, the waste water of factories, and the leachate of waste landfills.

  • PDF

Assessment of Volatile Organic Compounds in Blood and Urine among Residents around Camp Carroll (캠프 캐럴 인근 주민의 혈중 및 요중 휘발성 유기화합물 평가)

  • Lim, Hyun-Sul;Yang, Wonho;Kim, Geun-Bae;Cho, Young-Sung;Min, Young-Sun;Lee, Kwan;Lee, Duk Hee;Ju, Young-Su;Kim, Sunshin;Heo, Jung;Jung, Dayoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • Objectives: Exposure to volatile organic compounds such as trichloroethylene(TCE) and perchloroethylene(PCE), along with Agent Orange, that were issued around Camp Carroll US Army Base situated in Waegwan, Chilgok-gun, Gyeongsangbuk-do Province, Korea. The main objective of this study was to assess the exposure to TCE and PCE of residents of the area surrounding Camp Carroll. Methods: The TCE, PCE and trichloroethanol(TCEOH) concentrations in blood and trichlroroacetic acid(TCA) and TCEOH concentrations in urine were measured and analyzed in a total of 1,033 residents around Camp Carroll. TCA and TCEOH are metabolites of TCE and PCE, respectively. The information on demographic characteristics and exposure variables in relation to underground water were obtained through a questionnaire completed by the subjects. Results: TCE, PCE and TCEOH concentrations were not detected in blood. Detection rates of TCA and TECOH concentrations in urine were 98.5% and 36.6%, respectively. Creatinine-corrected average TCA and TCEOH concentrations were $12.23{\pm}23.81{\mu}g/g$ and $0.66{\pm}4.31{\mu}g/g$, respectively. A significant difference was not shown between the drinking group and no drinking group for underground water, which was assumed as a potential route of exposure to TCE and PCE through the consumption of ground water. However, females drinking ground water showed a significantly higher mean level of TCA in urine than did males. There was no significant difference according to drinking ground water as a potential source of exposure to TCE and PCE in residents around Camp Carroll. Conclusions: Considering the statistical analysis of factors affecting exposure to TCE and PCE in ground water along with previous reports, TCA in urine as exposure to TCE and PCE might not be appropriate because it is found in chlorinated drinking water. Therefore, TCA concentration in urine may be the result of drinking of chlorinated water.

Urinary Arsenic Species Concentrations and Related Factors among Residents Living near Abandoned Metal Mines (폐금속광산 지역 주민들의 요 중 비소종별 농도와 관련요인 평가)

  • Surenbaatar, Ulziikhishig;Seo, Jeong-Wook;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Chang, Jun-Young;Lee, Chul-Woo;Cho, Seong-Sik;Son, Hyun-Jin;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.655-666
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate urinary arsenic concentrations by arsenic species and to identify related factors among local residents near abandoned metal mines in Korea. Methods: Among the subjects of the Health Survey of Residents Near Abandoned Metal Mines for 2013-2017, 664 people were enrolled in this study. Urinary arsenic species analysis was performed using ICP/MS. Result: The geometric means (95% Confidence Interval) by urinary arsenic species were 0.15 (0.13-0.17) ㎍/L for AsIII, 0.64 (0.55-0.75) ㎍/L for AsV, and 1.21 (1.05-1.40) ㎍/L for inorganic arsenic. The geometric means of urinary MMA and DMA were 1.58 (1.35-1.86) ㎍/L and 77.93 (72.61-83.63) ㎍/L, respectively, and that of organic arsenic was 83.15 (77.80-88.88) ㎍/L. The concentration of inorganic arsenic in the group using groundwater as drinking water was 1.36 (1.13-1.64) ㎍/L, which was statistically significantly higher than the 1.00 (0.80-1.25) ㎍/L in the other drinking water groups. Regarding rice consumption, the concentration of inorganic arsenic in urine in the group whose consumption was more than half rice produced in the residential area was 1.32 ㎍/L, which was statistically significantly higher than that of the 1.12 ㎍/L for the group whose consumption was less than half. Conclusion: In the analysis of the factors affecting the urinary inorganic arsenic concentration of the residents of the abandoned metal mine area, the use of groundwater as drinking water and consumption of rice produced in the residential area were considered related factors.

Potential for Development of Bank Filtrate in the Nakdong River Basin (낙동강 유역의 강변여과수 개발 가능성)

  • 전흥배;김상일
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.4
    • /
    • pp.99-116
    • /
    • 1997
  • In order to obtain safe drinking water, free from surface contamination, a study to determine the potential for developing a bank-filtrate system in the Iryong and Yongsan, Nakdong River Basin, Korea was conducted. The main type of aquifer In the study area is alluvial, consisting mostly of sand and gravel. The hydraulic conductivity(k) of the Iryong and Yongsan test areas were 8.63${\times}$10$^-2$cm/s and 9.90${\times}$10$^-2$cm/s, respectively, indicating that these areas are satisfactory for bank filtrate production. Pilot plants(IRPL and YSPL) were set up In Iryong and Yongsan to monitor the change in the quality of bank-filtered water and to determine the effect pumping had on the surrounding hydrogeologic system. The pilot plants operated continuously for about two months and the data obtained were used to validate the groundwater flow model. Computer simulations were conducted to predict the effects of producing bank filtrate using MODFLOW. MODPATH was also linked with the flow model to analyze particle tracking. According to the results of the model simulations and the hydrogeologlc study, long-term pumping, the minimization of drawdown and the availability of uncontaminated sell and groundwater conditions for the catchment area were all Important factors for successful bank-titrate system development.

  • PDF