• 제목/요약/키워드: drift ratio

검색결과 373건 처리시간 0.022초

Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

  • Abdeddaim, Mahdi;Ounis, Abdelhafid;Shrimali, Mahendra K.;Datta, Tushar K.
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.197-208
    • /
    • 2017
  • Among various retrofitting strategies, use of semi-active control for retrofitting a building structure has gained momentum in recent years. One of the techniques for such retrofitting is to connect a weaker building to an adjacent stronger building by semi-active devices, so that performances of a weaker building are significantly improved for seismic forces. In this paper, a ten storey weaker building is connected to an adjacent stronger building using magneto-rheological (MR) dampers, for primarily improving the performance of the weaker building in terms of displacement, drift and base shear. For this, a fuzzy logic controller is specifically developed by fuzzyfying the responses of the coupled system. The performance of the control strategy is compared with the passive-on and passive-off controls. Pounding Mitigation between the two buildings is also investigated using all three control strategies. The results show that there exists a fundamental frequency ratio between the two buildings for which maximum control of the weaker building response takes place with no penalty on the stronger building. There exists also a fundamental frequency ratio where control of the weaker building response is achieved at the expense of the amplification of the stronger building. However, coupling strategy always improves the possibility of pounding mitigation.

Performance based assessment for tall core structures consisting of buckling restrained braced frames and RC walls

  • Beiraghi, Hamid;Alinaghi, Ali
    • Earthquakes and Structures
    • /
    • 제21권5호
    • /
    • pp.515-530
    • /
    • 2021
  • In a tall reinforced concrete (RC) core wall system subjected to strong ground motions, inelastic behavior near the base as well as mid-height of the wall is possible. Generally, the formation of plastic hinge in a core wall system may lead to extensive damage and significant repairing cost. A new configuration of core structures consisting of buckling restrained braced frames (BRBFs) and RC walls is an interesting idea in tall building seismic design. This concept can be used in the plan configuration of tall core wall systems. In this study, tall buildings with different configurations of combined core systems were designed and analyzed. Nonlinear time history analysis at severe earthquake level was performed and the results were compared for different configurations. The results demonstrate that using enough BRBFs can reduce the large curvature ductility demand at the base and mid-height of RC core wall systems and also can reduce the maximum inter-story drift ratio. For a better investigation of the structural behavior, the probabilistic approach can lead to in-depth insight. Therefore, incremental dynamic analysis (IDA) curves were calculated to assess the performance. Fragility curves at different limit states were then extracted and compared. Mean IDA curves demonstrate better behavior for a combined system, compared with conventional RC core wall systems. Collapse margin ratio for a RC core wall only system and RC core with enough BRBFs were almost 1.05 and 1.92 respectively. Therefore, it appears that using one RC core wall combined with enough BRBF core is an effective idea to achieve more confidence against tall building collapse and the results demonstrated the potential of the proposed system.

Seismic behavior of coupled wall structure with innovative quickly replaceable coupling beams

  • Li, Yong;Yu, Haifeng;Liang, Xiaoyong;Yu, Jianjun;Li, Pengcheng;Wang, Wei;Wang, Qizhi
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.293-303
    • /
    • 2022
  • In order to improve the seismic resilience of coupled wall structure, coupling beam with fuse has been developed to reduce the post-earthquake damage. However, the fuses often have a build-up I-shaped section and are relatively heavy to be replaced. Moreover, the fuse and the beam segments are usually connected by bolts and it is time-consuming to replace the damaged fuse. For reducing the repair time and cost, a novel quickly replaceable coupling beam with buckling-restrained energy dissipaters is developed. The fuse of the proposed coupling beam consists of two chord members and bar-typed energy dissipaters placed at the corners of the fuse. In this way, the weight of the energy dissipater can be greatly reduced. The energy dissipaters and the chords are connected with hinge and it is convenient to take down the damaged energy dissipater. The influence of ratio of the length of coupling beam to the length of fuse on the seismic performance of the structure is also studied. The seismic performance of the coupled wall system with the proposed coupling beam is compared with the system with reinforced concrete coupling beams. Results indicated that the weight and post-earthquake repair cost of the proposed fuse can be reduced compared with the typical I-shaped fuse. With the increase of the ratio of the beam length to the fuse length, the interstory drift of the structure is reduced while the residual fuse chord rotation is increased.

연층을 갖는 수직 비정형 건축물의 층수 및 코어 위치에 따른 지진손실함수 상관관계 분석 (Correlation of Seismic Loss Functions Based on Stories and Core Locations in Vertical-Irregular Structures)

  • 한상진;심정은;정민재;조재현;김준희
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.149-158
    • /
    • 2024
  • Piloti-type structures with vertical irregularity are vulnerable to earthquakes due to the soft structure of the first story. Structural characteristics of buildings can significantly affect the seismic loss function, calculated based on seismic fragility, and therefore need to be considered. This study investigated the effects of the number of stories and core locations on the seismic loss function of piloti-type buildings in Korea. Twelve analytical models were developed considering two variations: three stories (4-story, 5-story, and 6-story) and four core locations (center core, x-eccentric core, y-eccentric core, and xy-eccentric core). The interstory drift ratio and peak floor acceleration were assessed through incremental dynamic analysis using 44 earthquake records, and seismic fragility was derived. Seismic loss functions were calculated and compared using the derived seismic fragility and repair cost ratio of each component. The results indicate that the seismic loss function increases with more stories and when the core is eccentrically located in the piloti-type structure model. Therefore, the uncertainty due to the number of stories and core location should be considered when deriving the seismic loss function of piloti-type structures.

철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감 (The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.147-157
    • /
    • 2018
  • 철근콘크리트 교량에 대한 대부분의 내진설계기준들은 전체 교량 시스템의 붕괴를 방지하기 위한 성능보장설계를 암시적 또는 명시적으로 적용하고 있다. 이러한 개념 및 규정들을 명시하는 이유는 교량 전체 시스템에 설계지진하중이 작용하는 동안 철근콘크리트 교각들이 완전한 소성회전성능을 발휘할 때까지 구조적인 다른 구성요소들의 취성적인 파괴를 방지하기 위함이다. 이를 위해 철근콘크리트 교량에 대한 내진설계기준들에서는 취성적인 전단파괴를 피하도록 규정하고 있다. 성능보장의 중요한 요소 중의 하나가 교각의 연성거동을 보장하기 위한 전단강도가 충분히 확보되어야 하고 신뢰할 수 있어야 한다. 실험체 8개에 대하여 실험을 수행하였으며 모든 실험체에서 변위비 1.5%에서 다수의 휨-전단 균열이 발생되었고 최종단계까지 균열폭이 증가되었고 균열이 진전되었다. 휨-전단 균열의 각도는 부재 축과 $42^{\circ}{\sim}48^{\circ}$의 범위로 계측되었다. 본 연구에서는 실험에서 계측된 횡방향철근이 부담하는 전단강도에 대한 분석을 중심으로 하였다. 횡방향철근이 부담하는 전단강도, 축력 작용에 의한 전단강도, 콘크리트에 의한 전단강도 등 3요소에 대해 분석하였고 비교하였다. 실험체들의 콘크리트 응력은 도로 교설계기준의 응력한계를 초과하였다.

세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능 (Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars)

  • 김선우;장석준;윤현도;서수연;천영수
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2017
  • 현행 규정에 따르면, 세장비 4 미만의 연결보에 대각철근을 사용하도록 규정하고 있다. 그러나 대각선 다발철근 상세는 보 내부의 철근 배근작업을 어렵게 만들고, 이는 또한 시공불량으로 이어질 수 있다. 본 연구에서는 고강도 철근(SD500 및 SD600)으로 보강된 콘크리트 연결보에 관한 실험결과를 나타내었다. 연결보 제작시 시공성을 향상시키기 위하여, 본 연구에서는 헤드바를 갖는 대구경 철근을 사용하였다. 배근상세 및 세장비를 변수로 하여, 2가지의 실규모 연결보를 제작 및 실험하였다. 전단벽을 연결하는 보의 실제 거동특성을 모사하기 위하여, 링크 조인트를 갖는 철골 구조물을 반력바닥에 설치하였다. 실험 결과, 연결보와 전단벽 접합부에서의 균열 및 철근이 항복되면서, 점차 연결보 중앙부로 손상이 진전되는 것으로 나타났다. 연결보는 FEMA 450-1의 설계변위에 대한 전단벽 층간변위 규정에 요구되는 변형능력을 충분히 갖는 것으로 나타났다. 그러나 고강도 철근으로 보강된 연결보의 상세설계를 위해서는, 다양한 세장비가 연결보의 구조거동에 미치는 영향에 관한 연구가 필요하다.

프리캐스트 철근콘크리트 중공 말뚝과 기초 접합부 반복가력 거동 (Pile-cap Connection Behavior between Hollow-Head Precast Reinforced Concrete Pile and Foundation)

  • 방진욱;조영재;안경철;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.71-77
    • /
    • 2019
  • 지지력이 큰 하부지반에 구조물의 하중을 전달하기 위한 방안으로 말뚝기초가 대부분 적용되고 있다. 이 연구에서는 접합부에 보강되는 철근량에 따라 반복하중 하에서 프리캐스트공법과 철근 및 속채움 콘크리트로 말뚝머리부를 보강한 철근콘크리트 말뚝(HPC)과 기초 접합부 거동을 실험을 통해 평가하였다. 철근량에 변화에 따라 제작된 두 종류의 접합부 실험체의 균열패턴과 파괴거동은 유사한 수준으로 평가되었다. 철근량 1.77배 증가에 기인하여 BS-H25 실험체는 BS-H19 실험체에 비해 최고하중은 약 1.47배 증가하였지만 연성비는 정가력시 76%, 부가력시 70% 수준을 나타내었다. 강성감소는 접합부 철근 항복 이후 BS-H19 실험체와 BS-H25 실험체는 정가력시 초기강성의 약 66% ~ 71% 수준으로 부가력시 54% ~ 57% 수준으로 감소되었고 BS-H25 실험체가 평균 13% 높은 강성값을 나타내었다. 극한하중 상태에서의 BS-H19와 BS-H25 실험체의 누적 에너지 소산량은 사용하중 상태에 비해 약 5.5배 및 6.6배 큰 값으로 측정되었다.

브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가 (Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections)

  • 이강민;정희택;윤석용;이은모;오경환
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2008
  • 1994년 노스리지 지진 이후, 철골모멘트골조 강축방향 접합부의 내진성능 평가에 관한 연구가 국내 외에서 활발하게 진행되어온 반면, 국내 철골모멘트골조 내진설계 및 시공의 실무에 관행적으로 적용되고 있는 철골모멘트골조 약축방향 접합부의 내진성능 평가 연구가 국내는 물론 국외에서도 그 사례를 찾아보기 힘든 상황이다. 따라서 본 연구에서는 국내에서 내진성능 확보 여부가 확인되지 않은 상태에서 내진설계 실무에서 가장 많이 사용되고 있는 브라켓 형식 및 WUF-B 형식의 접합상세를 갖는 철골모멘트골조 약축접합부의 실물대(Full scale) 실험체를 제작 및 실험하여 이와 같은 형상의 접합부에 대한 내진성능을 평가하여 향후 이와 같은 형상을 갖는 철골모멘트골조 약축접합부의 설계를 위한 기초자료를 제공하는 것을 목적으로 한다. 이러한 목적을 달성하기 위하여, 현장조사 및 설계도서등의 기존 자료를 통해 총 2개의 실험체를 제작하여 내진성능을 평가 실험연구를 수행하였다. 실험결과로부터 최대내력 비교, 하중-변위 이력 및 응력도 등에 대한 거동을 비교 분석 하였다. 실험결과 층간변위각 5%의 BR-W 실험체가 층간변위각 4%를 갖는 WUF-B 실험체에 비해 우수한 구조적 거동을 보여주었으며, 설계 내력을 상회하는 내력을 보유하고 있는 것을 알 수 있었다. 또한 브라켓 형식의 실험체는 최대내력 도달 이후 완만한 강도 저하를 나타내었으나, WUF-B 형식의 실험체는 최대내력 도달 이후 급격한 하중 저하를 나타내며 취성적인 거동을 보였다.

전단스프링과 섬유요소를 이용한 철근콘크리트 전단벽의 비선형 해석모델에 관한 연구 (Nonlinear Modeling of RC Shear Walls Using Fiber and Shear Spring Elements)

  • 이광호;유태상;김태완;정성훈
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.559-566
    • /
    • 2012
  • 철근콘크리트 전단벽을 모델링하기 위해서 섬유요소와 전단스프링을 사용한 모델을 개발하였다. 섬유요소는 전단벽의 휨변형을 나타내며, 전단스프링은 전단변형을 나타낸다. 섬유요소는 단면치수와 비선형 재료성질을 입력하여 모델링되며, 전단스프링은 섬유요소모델과 VecTor2프로그램의 해석 결과로부터 그 변수들을 선정한다. 전단스프링은 전단변형에 의한 강도 강성 감소, 핀칭효과, 그리고 슬립현상을 모사할 수 있는 OpenSees의 Pinching4 모델을 사용하였다. 전단스프링의 변수선정과정은 복잡하고 시간이 오래 걸린다. 따라서 섬유요소모델의 사용성을 검토하기 위해 전단벽의 형상비(H/L), 보의 높이변화, 그리고 보와 전단벽의 강성비 휨강도비를 변수로 하여 전단벽 건물에 동적해석을 수행하였다. 전단벽의 형상비는 섬유요소모델을 사용한 모델과 섬유요소와 전단스프링을 함께 사용한 모델의 층간변위비 오차와 일정한 관계를 가진다. 하지만 보의 높이변화와 강성비 휨강도비 변화에 두 모델의 오차는 일정한 관계를 보이지 않는다.

콘크리트 채움 U형 메가 합성보의 내진성능 평가 (Seismic Performance Evaluation of Concrete-filled U-shaped Mega Composite Beams)

  • 이철호;안재권;김대경;박지훈;이승환
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.111-122
    • /
    • 2017
  • 본 연구에서는 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보의 합성보통모멘트골조에 대한 적용성을 검토하였다. 대형 합성보의 실물대 내진성능실험에 대한 현실적 제약으로 인하여 작은 규모의 실험체에 대해 수행된 기존 실험결과의 분석과 수치해석연구의 보완을 통해 연구를 수행하였다. 이러한 형태의 합성보는 부모멘트 작용시의 웨브국부좌굴이 가장 중요하므로 선행 실물대 실험결과로부터 웨브의 판폭두께비와 층간변형능력 사이의 관계를 분석하였다. 그 결과, 25mm 두께의 U형 강재단면을 지닌 1900mm급의 대형 합성보라 하더라도 층간변위각 2% 이후 웨브국부좌굴을 경험하고 3% 이후 최대변형에 도달하는 것으로 확인되었다. 이는 합성보통모멘트골조의 요구조건을 상회하는 것으로 AISC 기준에 따른 웨브 판폭두께비 제한이 본 연구의 U형 단면에는 보수적임을 시사하기도 한다. 유한요소해석을 통해서는 합성보의 휨성능 및 웨브국부좌굴에 대한 수평스티프너의 영향을 분석하였다. 대형 합성보는 스티프너 보강과 관련없이 부모멘트 방향으로 공칭소성모멘트 이상의 휨성능을 발휘하였으며, 스티프너를 보강할 경우에는 웨브국부좌굴이 상당히 지연되는 긍정적인 효과가 있었다. 이상의 실험결과 분석 및 해석연구에 의하면 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보는 합성보통모멘트골조에 보수적으로 적용가능한 것으로 판단된다.