• Title/Summary/Keyword: double resonance

Search Result 247, Processing Time 0.022 seconds

A Study of the SPWM High-Frequency Harmonic Circulating Currents in Modular Inverters

  • Xu, Sheng;Ji, Zhendong
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2119-2128
    • /
    • 2016
  • Due to detection and control errors, some high-frequency harmonics with voltage-source characteristics cause circulating currents in modular inverters. Moreover, the circulating currents are usually affected by the output filters (OF) of each module due to their filter and resonance properties. The interaction among the circulating currents in the modules increase the power loss and reduce system stability and control precision. Therefore, this paper reports the results of a study on the SPWM high-frequency harmonics circulating currents for a double-module VSI. In the paper, an analysis of the circulating-current circuits is briefly described. Next, a mathematic model of the single-module output voltage based on the carrier frequency of SPWM is built. On this basis, through mathematic modeling of high-frequency harmonic circulating currents, the formation mechanism and distribution characteristics of circular currents and their influences are studied in detail. Finally, the influences of the OF on the circulating currents are studied by mainly taking an LC-type filter as an example. A theoretical analysis and experimental results demonstrate some important characteristics. First, the carrier phase shifting of the SPWM for each module is the major cause of the SPWM harmonic circulating currents, and the circulating currents are in an odd distribution around n-times the carrier frequency $n{\omega}_s$, where n = 1, 2, 3, ${\ldots}$. Second, the harmonic circular currents do not flow into the parallel system. Third, the OF can effectively suppress the non-circulating part of the high-frequency harmonic currents but is ineffective for the circulation part, and actually reduces system stability.

Design of a Dual-Frequency Microstrip Patch Antenna (이중 공진형 마이크로스트립 패치 안테나 설계)

  • 김규성;김태우;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1131-1137
    • /
    • 1999
  • In this paper, a novel design method of an apertured coupled microstrip patch antenna with the single feeding structure is proposed for dual resonance frequencies with mutually perpendicular polarizations. The characteristics of this antenna are experimentally investigated. In order to achieve this goal, a new type of square patch with double notches is used as a radiator and the crossed slot and the bended mictrostrip feeder are adopted for the dual polarizations in the aperture-coupled structure. For the application of the proposed antenna, a Ku-band Tx/Rx $2\times$ subarray antenna is designed and manufactured. Also, the applicability of the antenna as a ground terminal is examined through performance analysis. According to the measurement, the gain of the antenna is 10dBi at the center frequencies of Tx and Rx, the side lobe level is lower than -13dB, and the cross polarization lebel is below 17 dB.

  • PDF

Design of L-shaped Dual Inset Feeding Microstrip Stacked Patch Antenna for 2.5GHz Band (이중 L형 인셋 급전된 2.5GHz용 적층 마이크로 스트립 안테나의 설계)

  • Kim, Gun-Kyun;Kim, On;Rhee, Seung-Yeop
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.461-466
    • /
    • 2019
  • In this paper, we have studied the improvement of gain and bandwidth characteristics by using double feeding and L-shaped inset feed line matching circuit in microstrip stacked patch antenna which is widely used to broaden the gain of general microstrip antenna. The proposed structure is composed of two feeding edges of the main patch antenna, each of them are connected to a feeding line having an L shaped inset feeder. And the parasitic patch is placed at a proper distance above the main patch. The size of the main patch is designed so that the resonance frequency is close to the center frequency of the target frequency band. The experimental results show that the bandwidth was increased more than 180MHz in the 2.3-2.7 GHz band, which is more interesting than the single feed, and the gain improvement of 2.5dBi was obtained at 2.7GHz.

Quasi-optical design and analysis of a remote steering launcher for CFETR ECRH system

  • Zhang Chao;Xiaojie Wang;Dajun Wu;Yunying Tang;Hanlin Wang;Dingzhen Li;Fukun Liu;Muquan Wu;Peiguang Yan;Xiang Gao;Jiangang Li
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1619-1626
    • /
    • 2024
  • In order to optimize the operational safety and reliability of the upper launcher for the CFETR ECRH system, a design of the launcher for NTM control based on the remote steering concept is currently being carried out for comparison with the front steering equivalent. This paper presents the layout design and analysis of the quasi-optical system in the remote steering launcher. A 3D visual quasi-optical design tool has been developed for the quasi-optical system, which can parameterize modeling, perform general astigmatic beam calculation and show the accurate beam propagation path in the upper port. Three identical sets of quasi-optical modules are arranged in the launcher, and each one consists of two fixed double-curvature focusing mirrors, which focus and reflect the steering beams (- 12°-12°) from two square corrugated waveguides. The beam characteristics at the resonance layer are described, and the average beam radius is < 100 mm. The peak head loads on the surfaces of the two fixed mirrors are 1.63 MW/m2 and 1.52 MW/m2. The position and size of the beam channel in the blanket are obtained, and the opening apertures on the launcher-facing and plasma-facing sides of the blanket module are 0.54 m2 and 0.4 m2, respectively.

A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study (자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구)

  • Park Tae-Soo;Choi Il-Yong;Joo Kyung-Bin;Kim Sun-Il;Kim Jun-Sic;Paik Doo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • Purpose : The purpose of this study is to demonstrate changes in the orientation ortho glenohumeral ligaments(GHL) in different degrees of abduction and rotation of the normal healthy individuals. Materials and Methods : Saline Magnetic Resonance(MR) arthrography of nine consecutive shoulders of normal healthy adults were checked. At that time, MR images were obtained in three different positions of abduction and external rotation($0^{\circ}C\;and\;0^{\circ},\;45^{\circ}C\;and\;25^{\circ}C,\;90^{\circ}$ and maximum, respectively). From a series of consecutive MRI, three-dimensional images were reconstructed after detecting the location of the middle glenohumeral ligament(MGHL) and the inferior glenohumeral ligament(IGHL) using workstation computer. Results : The shape of the MGHL was taken in double curved, and straight, and finally curved again in three different positions of the shoulder in sequence. On the other hand, the shape of the IGHL was obliquely positioned, and curvilinear, and finally straight and extended at lower part of the anterior surface of the humeral head. Conclusions : At $45^{\circ}$ of abduction and $25^{\circ}$ of external rotation, and at $90^{\circ}$ of abduction and maximal external rotation of the shoulder, the MGHL and the IGHL had the role of the most important static stabilizer of the glenohumeral joint repectively.

  • PDF

Study on the Fire Cause Analysis for Explosives Waste by Thermal Analysis Experiment (열분석 실험에 의한 화약류 폐기물의 화재원인분석에 관한 연구)

  • Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.1
    • /
    • pp.89-100
    • /
    • 2018
  • when the explosive wastes to be treated as designated wastes are brought into the wastes treatment plant by mistake and lead to an explosion in the wastes disposal process, many people and property damage are involved. Waste should be treated properly. As mentioned in this paper, ignition reac- tion tests of ignitable re-burning of explosives packing material waste (solid butadiene) confirmed that ignition was easily occurred, and that even small ignition sources were easily ignited and burned quickly and explosively. In particular, when explosives are loaded into incineration wastes in large quantities and mixed with organic compound wastes, such as fire and explosion accidents caused by explosives packing materials at waste disposal sites, flammable and oxidative gases are generated due to mutual oxidation and pyrolysis It is confirmed that there is a possibility that ignition sources such as spark ignite and instantaneously lead to explosion. It is hoped that this study will be a small reference for on - site detection in the field of fire, and it is expected that the fire - fighting agency will be recognized as a fire investigation agency and will contribute to the improvement of the credibility.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Comparison of Inhibitory Effect of 17-DMAG Nanoparticles and Free 17-DMAG in HSP90 Gene Expression in Lung Cancer

  • Mellatyar, Hassan;Akbarzadeh, Abolfazl;Rahmati, Mohammad;Ghalhar, Masoud Gandomkar;Etemadi, Ali;Nejati-Koshki, Kazem;Zarghami, Nosratallah;Barkhordari, Amin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8693-8698
    • /
    • 2014
  • Background: Up-regulation of hsp90 gene expression occurs in numerous cancers such as lung cancer. D,L-lactic-co-glycolic acid-poly ethylene glycol-17-dimethylaminoethylamino-17-demethoxy geldanamycin (PLGA-PEG-17DMAG) complexes and free 17-DMAG may inhibit the expression. The purpose of this study was to examine whether nanocapsulating 17DMAG improves the anti cancer effect over free 17DMAG in the A549 lung cancer cell line. Materials and Methods: Cells were grown in RPMI 1640 supplemented with 10% FBS. Capsulation of 17DMAG is conducted through double emulsion, then the amount of loaded drug was calculated. Other properties of this copolymer were characterized by Fourier transform infrared spectroscopy and H nuclear magnetic resonance spectroscopy. Assessment of drug cytotoxicity on the grown of lung cancer cell line was carried out through MTT assay. After treatment, RNA was extracted and cDNA was synthesized. In order to assess the amount of hsp90 gene expression, real-time PCR was performed. Results: In regard to the amount of the drug load, IC50 was significant decreased in nanocapsulated(NC) 17DMAG in comparison with free 17DMAG. This was confirmed through decrease of HSP90 gene expression by real-time PCR. Conclusions: The results demonstrated that PLGA-PEG-17DMAG complexes can be more effective than free 17DMAG in down-regulating of hsp90 expression by enhancing uptake by cells. Therefore, PLGA-PEG could be a superior carrier for this kind of hydrophobic agent.

Vibration of Contact Lenses (콘택트 렌즈의 진동에 관한 연구)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.13-29
    • /
    • 2001
  • A mathematical model was proposed to analyze the vibration of diaphragm, such as the contact lenses fitted on the eyes, being subjected to the external sinusoidal pressure. The model incorporates the differential equations and their numerical solution program, based on the wave equations. Turbo-C and graphic software, formulated to describe the dependence of the various parameters involved in the vibration. The model predicts the radial distribution of amplitude, frequency dependence of both average displacement amplitude and the power of diaphragm whose edge is being either simply supported or rigidly clamped in vibration. The effect of variables such as thickness, radius, damping coefficients on the vibration characteristics was illustrated by the computer simulation of the derived program. As the frequency of driving pressure increases above the certain value determined by the boundary conditions and parameters the wave shape or pattern changes from simple arc to belly or loops having double antinode. It seems that the effect of outer antinode progressively increases as the frequency increases. If this kind of phenomena occurs to the contact lens on the cornea in vivo, it may cause an abnormal correction power in the lenses or pull off the eye due the increased rise of outer part of the lens.

  • PDF

Identification of Petroselinic Acid (Cis-6-octadecenoic Acid) in the Seed Oils of Some of the Family Umbelliferae (Panax schinseng, Aralia continentalis and Acanthopanax sessiliflorus) by GC-MS, IR, $^1H-and$ $^13C-NMR$ Spectroscopic Techniques

  • Kim, Seong-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.323-331
    • /
    • 2005
  • Fatty acid compositions of the seed oils of P. schinseng, A. continentalis and A. sessiliflorus, were analyzed by gas chromatography (GC) equipped with a capillary column. A large unusual peak was observed just before the peak corresponding to oleic acid $(cis-9-C_{18:1})$. This unknown fatty acid was isolated by silver ion chromatography and then derivatized into the picolinyl ester. The mass spectrum of the picolinyl ester showed molecular ion at m/z=373 with other diagnostic ions such as m/z=178, 218, 232, 246, 274, 288, 302 and 344. Characteristic absorption peaks at $720\;cm^{-1}$, $1640\;cm^{-1}$ and $3010\;cm^{-1}$ in IR spectrum indicated the presence of cis-configurational double bond in the molecule. The $^1H-NMR$ spectrum of this acid gave two quintets centered at ${\delta}1.638$ (2H, C-3) and ${\delta}1.377$ (2H, C-4), and two multiplets centered at ${\delta}2.022{\sim}2.047$ (2H, C-5) and ${\delta}2.000{\sim}2.022$ (2H, C-8), and multiplet signals of olefinic protons centered at ${\delta}5.3015{\sim}5.3426$ (C-6, J=9.5 Hz) and ${\delta}\;5.3465{\sim}5.3877$ (C-7, J=9.5 Hz). The $^13C-NMR$ spectrum showed 18 carbon resonance signals including an overlapped signal at ${\delta}29.7002$ for C-12 and ${\delta}29.6520$ for C-13 (or they can be reversed), and other highly resolved signals at ${\delta}33.950$, ${\delta}24.558$, ${\delta}26.773$ and ${\delta}27.205$ due to C-2, C-3, C-5 and C-8 of a ${\Delta}^6-octadecenoic$ acid, respectively. From analysis results this unknown fatty acid could be identified as cis-6-octadecenoic acid. The seed oils of P. schinseng and A. sessiliflorus contained petroselinic acid (59.7%, 56.0%), oleic acid (18.3%, 6.1%) and linoleic acid (16.2%, 30.4%) with small amount of palmitic acid (3.0%, 3.1%) while the seed oil of A. continentalis comprised mainly oleic acid (30.2%), petroselinic acid (29.0%), linoleic acid (24.1%) and palmitic acid (13.1%).