• Title/Summary/Keyword: double plates

Search Result 162, Processing Time 0.022 seconds

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

A Study on Comparison Experiments for Judgement to the Nondestructive Analysis of Gold Plated Silverware Remains (비파괴분석법에 의한 은제금도금유물의 판단을 위한 비교실험 연구)

  • Sim, Myung-Bo;Yu, Hei-Sun;Kim, Soo-Ki
    • Journal of Conservation Science
    • /
    • v.27 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • If the nondestructive analysis is carried out by using an X-ray Fluorescence Analyzer(XRF) for ingredient analysis with the target of gold plated silverware that plates gold on a silver basis, a singular point showing big difference at the value of weight percent(wt.%) according to the electron orbit of the principal ingredient can be confirmed. The present research made reproduced samples and carried out comparative analysis in order to suggest a basis that can judge whether the technique of gold plated silverware was used in case of remains uneasy to understand with eyes by using this singular point. As a result, the same result as analysis results of actual remains could be seen in specimens manufactured by a mercury amalgam plating method. However, in case of gold and silver alloy specimens, it could be confirmed that the difference according to the electron orbit of the principal ingredients is slight unlike plated specimens. The reason appearing at plated specimens seems to be generated while absorbing XRF beam at plated layers by double structure due to plating instead of single material. Accordingly, if this result appearing at nondestructive analysis is used, it was confirmed that the application of the technique of gold plated silverware can be judged without observing its section.