• 제목/요약/키워드: double layers covering

검색결과 8건 처리시간 0.023초

토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성 (Characteristics of PPF Transmittance and Heat Flow by Double Covering Methods of Plastic Film in Tomato Greenhouse)

  • 이현우;심상연;김영식
    • 한국농공학회논문집
    • /
    • 제52권5호
    • /
    • pp.11-18
    • /
    • 2010
  • This study was conducted to provide design data for deciding covering method in double layers greenhouse. The variation of photosynthetic photon flux (PPF) and heat flow in air inflated and conventional double layers greenhouse was analyzed. The PPF of air inflated double covering greenhouse was less than that of conventional greenhouse during summer season because the more PPF comes into conventional greenhouse through roof vent which was rolled up for ventilation. The air inflated double layers covering greenhouse was superior to conventional type in the aspect of controlling inside temperature down owing to lower irradiation. The PPF of air inflated greenhouse was greater than that of conventional greenhouse during winter season because the transmittance of conventional greenhouse decreased by dust collected on inside plastic film nearly closed for insulation. Considering the PPF not sufficient for tomato growing in winter, the air inflated double covering system with the greater transmittance was better than conventional covering system. When the inside air of air inflated greenhouse was injected into space between the double layers of covering, the PPF of air inflated greenhouse was much less than the conventional greenhouse because the transmittance of air inflated double covering decreased due to condensation of highly humidified inside air. It was concluded that the more dried outside air should be used for inflating double layers covering. The heat insulation performance of air inflated double covering system was superior to conventional double covering system when comparing the overall heat transfer coefficients for each covering method. However the differences among the overall heat transfer coefficients depending on difference between inside and outside temperatures of greenhouse were great, it is necessary to conduct additional experiment for investigating the overall heat transfer coefficient to design the double layers covering.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

플라스틱온실 피복재의 관류열전달계수 변화 (Variation of the Overall Heat Transfer Coefficient of Plastic Greenhouse Covering Material)

  • 이현우;소레이멘디옵;김영식
    • 생물환경조절학회지
    • /
    • 제20권2호
    • /
    • pp.72-77
    • /
    • 2011
  • 본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.

Ultrathin Polymer Networks of Itaconic Acid Copolymers and Poly(allkylamine) by the ;angmuir-Blodgett Technique

  • 최기선;이범종;장상목;권영수
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권6호
    • /
    • pp.493-498
    • /
    • 1995
  • Ultrathin networks of itaconic acid copolymers and poly(allylamine) were produced by a Langmuir-Blodgett (LB) technique employing a double-chain amine as a monolayer template which was subsequently removed by extraction after thermal crosslinking. Itaconic acid copolymers used were copoly (itaconic acid-ethyl vinyl ether) and copoly (itaconic acid-n-butyl vinyl ether). The polyion-complexed monolayers of three components consisting of template amine, itaconic acid copolymer and poly (allylamine) were formed at the air-water interface. The Langmuir film properties have been studied by the surface pressure-area isotherm and fluorescence microscopy. The monolayers were transferred on solid substrates and were characterized by FT-IR spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy (SEM). Two-dimensional polymer networks were formed through imide or amide linkages by heat treatment under vacuum. The heat-treated films were extracted with chloroform after immersion in aq. sodium chloride to remove the template amines. SEM observation of a LB film on a porous fluorocarbon membrane filter with pore diameter of 0.1 μm showed covering of the pores by six layers in the polyion complex state.

이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성 (Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse)

  • 이현우;심상연;김영식
    • 생물환경조절학회지
    • /
    • 제21권1호
    • /
    • pp.1-11
    • /
    • 2012
  • 관행 이중피복온실과 공기주입 이중피복온실에 대하여 보온, 난방, 환기, 냉방 등 환경조절에 따른 온실내부의 환경변화를 연중 측정하여 온습도 및 광환경 분포특성을 비교분석함으로서 기존 온실의 환경을 개선할 수 있는 방안을 제시하기 위해 수행한 연구결과를 요약하면 다음과 같다. 겨울철 야간에 난방시 공기주입온실과 관행온실의 커튼과 피복재 사이의 온도는 거의 비슷한 값을 보여주고 있어 보온효과는 거의 동일한 것으로 나타났다. 온실내부의 커튼 안쪽의 습도는 난방으로 인해 외부습도보다 낮게 유지되었으나 커튼과 피복재 사이의 습도는 거의 100%로 유지되었다. 주간의 우천시에도 두 가지 온실의 내부온도가 거의 비슷하여 보온효과는 동일한 것으로 나타났다. 주간에 천창환기시 두 온실 모두 일사로 인해 상하방향으로 온도의 편차가 크게 발생하였고, 공기주입온실이 관행온실에 비해 온도가 약간 더 낮기 때문에 환기효과가 더 우수한 것으로 판단된다. 온도분포와 마찬가지로 상하방향으로 습도편차가 크게 발생하였으며, 공기주입온실이 관행온실에 비해 습도가 약간 더 높게 나타나 환기효과가 더 우수한 것으로 판단된다. 야간에 천창환기시에는 두 온실 모두 주간과는 달리 일사가 없기 때문에 온실내부 전체적으로 균일한 온습도분포를 보여주고 있다. 간헐적 포그분사 냉방을 실시하였을 때 두 온실 모두 상하좌우로 비교적 균일한 온습도분포를 보여주었다. 연속 포그분사 냉방을 실시한 경우 전체적으로 균일한 온습도 분포를 보여주었으며, 평균 약 $3.5^{\circ}C$ 정도의 냉방효과가 있는 것으로 나타났다. 커튼과 지붕피복재 사이의 공간에 대한 상대습도와 절대습도의 변화를 분석한 결과 거의 커튼을 닫는 시점에서 피복재의 온도가 노점 온도 이하로 낮아지기 시작하기 때문에 커튼을 닫음과 동시에 제습기를 사용하여 지붕과 커튼 사이 공간의 공기에 함유된 수증기를 제거하면 지붕의 피복재에 발생하는 결로를 억제할 수 있을 것으로 판단된다. 피복재의 사용기간이 경과함에 따라 공기주입온실에 비해 관행온실이 광투과율이 더 감소하는 것으로 나타났다. 이는 온실내부 피복재를 권취식으로 개폐하는 과정에서 먼지와 결로로 인해 오염되기 때문인 것으로 판단된다. 따라서 피복재의 광투과율이 감소되는 것을 방지하기 위해서는 피복재의 권취식 개폐방식을 지양하는 것이 바람직할 것으로 판단된다. 결론적으로 온실의 이중피복 방법을 공기주입 이중피복형태로 하고 천창을 용마루 위치에 나비형태로 설치한다면 관행 이중피복 온실과 동일한 에너지절감효과를 유지하면서 광투과율을 현저히 개선할 수 있고 환기효율도 높일 수 있을 것으로 판단된다.

온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구 (A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse)

  • 이종원;김동건;이현우
    • Current Research on Agriculture and Life Sciences
    • /
    • 제33권2호
    • /
    • pp.41-47
    • /
    • 2015
  • 본 연구는 온실용 피복재 및 보온재의 조합에 대한 시뮬레이션 해석모델을 개발하여 관류열전달계수를 산정하고 측정된 결과와 비교하여 타당성을 평가하기 위해 수행되었으며 결과를 요약하면 다음과 같다. 유리이중피복의 경우 이중피복 사이의 공기층이 두꺼워짐에 따라 관류열전달계수가 서서히 작아져서 공기층 두께가 25 mm 이상이 되면 관류열전달계수의 변화가 거의 없는 것을 확인할 수 있었다. 또한 온도차가 증가함에 따라 관류열전달계수도 증가하는 것을 확인할 수 있었다. 두 플라스틱 피복재 사이에는 대류에 의한 열전달이 활발하게 일어나기 때문에 비정상 유동에 의한 열전달이 발생하고 이로 인해 온도분포도 비선형적으로 변하는 것으로 사료된다. 플라스틱 피복재 및 보온재들의 간격이 50~200 mm범위에서 변화할 때에 피복재의 간격은 관류열전달계수 큰 영향을 미치지 않는다는 사실을 확인할 수 있었다. 천공복사를 고려한 경우와 고려하지 않은 경우 모두 핫박스의 내외부 온도차가 $30^{\circ}C$인 조건에 대해서는 수치해석결과와 실험결과가 대체로 잘 일치하였다. 따라서 핫박스의 내외부 온도차가 $30^{\circ}C$ 이상인 조건에서 수치해석을 통해 관류열전달계수를 산정한다면 신뢰성 있는 값을 얻을 수 있을 것으로 판단된다.

PO필름 피복 온실의 수량 증대 및 에너지 절감 효과 (Yield Increase and Energy Saving Effect on Plastic Greenhouse Covered with Polyolefin Film)

  • 문종필;박석호;김진구;이재한;강연구;임미영;김혜민
    • 생물환경조절학회지
    • /
    • 제29권4호
    • /
    • pp.428-439
    • /
    • 2020
  • 본 연구는 PO필름과 PE필름을 온실의 피복재로 적용하였을 때 작물 수량 증대 및 에너지 절감에 미치는 영향을 조사하였다. 시험온실은 국립원예특작과학원 시설원예연구소 내에 위치한 단동온실(1-1W) 2동(B21, B23)과 2연동온실(1-2W형) 2동(B15, B16)을 사용하였다. 단동온실의 규격은 폭 7.2m, 길이 30m, 측고 1.5m, 동고 3.6m 이고, 연동온실의 규격은 폭 8m, 길이 40m, 측고 3.1m, 동고 5.8m의 온실로서 이 중 골조로 된 아치형 표준온실이다. 동절기 시험을 위하여 PO필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동의 온실 피복재로 사용하였으며 대조구 온실로서 PE필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동에 설치하였다. 시험작물은 완숙토마토 '해피니스'를 토양재배 하였고 2019년 12월3일에 정식하여 2020년 4월 30일까지 재배하였다. 온실내부 야간 설정온도는 15℃를 유지하였으며 주간에는 23~24℃를 유지할 수 있도록 측창 및 천창을 개방하였다. PO필름의 단동 및 연동온실 내부에서의 일사량, 온습도 등을 측정하였고, 재배 기간 동안의 생육량을 조사하였으며 에너지 절감 효과를 조사하기 위해 피복재별 시험온실의 온풍난방기 연료 소비량을 조사하였다. 조사 결과 단동온실에서의 일사량은 PO필름 온실에서 PE필름 온실보다 7% 증가하였고 수확량은 20% 증대되었다. 연동온실에서의 일사량은 PO필름 온실에서 PE필름 온실보다 11% 증가되었고, 수확량은 9% 증가하였다. 또한 온실내부의 일평균 온습도 측정 결과 단동온실은 PE, PO필름 온실이 19.0℃, 19.1℃, 상대습도 75%를 나타냈고 연동온실은 PO필름 온실이 19.6℃, 상대습도 57%를 나타냈고 PE필름 온실이 18.8℃, 상대습도 63%를 나타냈다. 연료 소비량은 단동온실의 PO필름 온실이 PE필름 온실보다 12.4% 절감되었고 연동온실에서는 PO필름 온실이 PE필름 온실보다 11.5% 절감된 것으로 나타났다.

모바일 기반 온실 냉난방 부하 산정 프로그램 개발 (Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile)

  • 문종필;방지웅;황정수;장재경;윤성욱
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.419-428
    • /
    • 2021
  • 모바일 기반 온실에너지 계산프로그램을 제작하기 위해 먼저 주요 단일 피복재 10종 및 보온재 16종에 대한 열관류율 측정하였다. 또한 피복 및 보온재를 이중 및 삼중으로 다층 설치할 때 열관류율 추정을 위하여 이중 설치시 24조합, 삼중설치 시 59조합에 대한 열관류율을 핫박스를 이용하여 측정하였다. 단일 피복재에서는 PE필름(0.08mm) 대비 PO필름(0.15mm)이 가장 열관류율이 가장 작고 열절감율이 가장 큰 것으로 나타났다. 단일 보온재에서는 열관류율에서는 외피가 있는 5겹의 다겹보온커튼이 가장 보온력이 좋은 것으로 나타났다. 또한 단일자재에 대한 열관류율 값과 열저항값을 이용한 피복 및 보온재의 다층설치시의 총 열관류율 값을 산정하였고 실측 값과의 오차를 보정하는 선형회귀식을 도출하였다. 단일재료의 열관류율값에 의한 피복 및 보온재의 다층설치시 열관류율 추정 모형을 개발한 결과 모형평가지수가 0.90(0.5 이상일 때 양호)으로 나타나 추정치가 실측치를 매우 잘 재현 하고 있는 것으로 나타났다. 또한 시험온실을 통한 실증시험결과 예측된 열절감율이 실측치보다 상대오차 2%로 작게 나타나는 것으로 평가되었다. 이러한 연구결과를 기반으로 모바일 기반의 온실 에너지계산 프로그램을 개발하였다. 이 프로그램은 HTML5 표준 웹 기반 모바일 웹 애플리케이션으로 구현하였으며 N-Screen 지원을 통해 다양한 모바일 장치 및 PC 브라우저에서 동작이 가능하게 제작되었다. 또한 온실 피복(12종) 및 보온재(16종)의 조합별 열관류율 및 난방부하계수를 제공하여 농민이 모바일로 온실 위치, 형태 및 피복·보온재 등을 반영한 최대 주야간 냉난방부하 및 기간 난방부하를 산정할 수 있다. 대상 온실의 에너지 소비량에 대한 평가가 가능하며 온실의 지역 및 형태에 따라 피복 및 보온재의 최적 선택으로 에너지 절감형 온실 설계가 가능할 것으로 판단되었다.