• Title/Summary/Keyword: double difference model

Search Result 106, Processing Time 0.033 seconds

Head Gesture Recognition using Facial Pose States and Automata Technique (얼굴의 포즈 상태와 오토마타 기법을 이용한 헤드 제스처 인식)

  • Oh, Seung-Taek;Jun, Byung-Hwan
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.12
    • /
    • pp.947-954
    • /
    • 2001
  • In this paper, we propose a method for the recognition of various head gestures with automata technique applied to the sequence of facial pose states. Facial regions as detected by using the optimum facial color of I-component in YIQ model and the difference of images adaptively selected. And eye regions are extracted by using Sobel operator, projection, and the geometric location of eyes Hierarchical feature analysis is used to classify facial states, and automata technique is applied to the sequence of facial pose states to recognize 13 gestures: Gaze Upward, Downward, Left ward, Rightward, Forward, Backward Left Wink Right Wink Left Double Wink, Left Double Wink , Right Double Wink Yes, and No As an experimental result with total 1,488 frames acquired from 8 persons, it shows 99.3% extraction rate for facial regions, 95.3% extraction rate for eye regions 94.1% recognition rate for facial states and finally 99.3% recognition rate for head gestures. .

  • PDF

Performance evaluation of double stack vehicle at container terminal (2단 적재차량의 컨테이너 이송능력 분석)

  • Ha Tae-Young;Choi Yong-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.255-261
    • /
    • 2005
  • The purpose of this paper is to analyze transport ability of Automated Guided Vehicle(AGV) and Double Stack Vehicle(DSV) at Automated Container Terminal(ACT). Usually, the main difference of AGV and DSV is capacity of container that they can transport between apron and yard block at once. AGV can carry out two 20 feet or one 40 feet maritime containers, but DSV can carry out four 20 feet or two 40 feet maritime containers. Therefore, DSV may improve more efficiency of stevedoring system of container terminal. In this paper, a simulation model using a graphics simulation system is developed to compare the proposed DSV with the current AGV at automated container terminal. The paper includes examples, performance tests and a discussion of simulation results.

  • PDF

Autonomous Real-time Relative Navigation for Formation Flying Satellites

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.59-74
    • /
    • 2009
  • Relative navigation system is presented using GPS measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide the real-time inter-satellite relative positions as well as absolute positions for two formation flying satellites in low earth orbit. To improve the navigation performance, the absolute states are estimated using ion-free GRAPHIC (group and phase ionospheric correction) pseudo-ranges and the relative states are determined using double differential carrier-phase data and singled-differential C/A code data based on the extended Kalman filter and the unscented Kalman filter. Furthermore, pseudo-relative dynamic model and modified relative measurement model are developed. This modified EKF method prevents non-linearity of the measurement model from degrading precision by applying linearization about absolute navigation solutions not about the priori estimates. The LAMBDA method also has been used to improve the relative navigation performance by fixing ambiguities to integers for precise relative navigation. The software-based simulation has been performed and the steady state accuracies of 1 m and 6 mm ($1{\sigma}$ of 3-dimensional difference errors) are achieved for the absolute and relative navigation using EKF for a short baseline leader/follower formation. In addition, the navigation performances are compared for the EKF and the UKF for 10 hours simulation, and relative position errors are mm-level for the two filters showing the similar trends.

Vibration analysis and optimization of functionally graded carbon nanotube reinforced doubly-curved shallow shells

  • Hammou, Zakia;Guezzen, Zakia;Zradni, Fatima Z.;Sereir, Zouaoui;Tounsi, Abdelouahed;Hammou, Yamna
    • Steel and Composite Structures
    • /
    • v.44 no.2
    • /
    • pp.155-169
    • /
    • 2022
  • In the present paper an analytical model was developed to study the non-linear vibrations of Functionally Graded Carbon Nanotube (FG-CNT) reinforced doubly-curved shallow shells using the Multiple Scales Method (MSM). The nonlinear partial differential equations of motion are based on the FGM shallow shell hypothesis, the non-linear geometric Von-Karman relationships, and the Galerkin method to reduce the partial differential equations associated with simply supported boundary conditions. The novelty of the present model is the simultaneous prediction of the natural frequencies and their mode shapes versus different curvatures (cylindrical, spherical, conical, and plate) and the different types of FG-CNTs. In addition to combining the vibration analysis with optimization algorithms based on the genetic algorithm, a design optimization methode was developed to maximize the natural frequencies. By considering the expression of the non-dimensional frequency as an objective optimization function, a genetic algorithm program was developed by valuing the mechanical properties, the geometric properties and the FG-CNT configuration of shallow double curvature shells. The results obtained show that the curvature, the volume fraction and the types of NTC distribution have considerable effects on the variation of the Dimensionless Fundamental Linear Frequency (DFLF). The frequency response of the shallow shells of the FG-CNTRC showed two types of nonlinear hardening and softening which are strongly influenced by the change in the fundamental vibration mode. In GA optimization, the mechanical properties and geometric properties in the transverse direction, the volume fraction, and types of distribution of CNTs have a considerable effect on the fundamental frequencies of shallow double-curvature shells. Where the difference between optimized and not optimized DFLF can reach 13.26%.

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Two different reaction mechanisms of cinnamate side groups attached to the various polymer backbones

  • Hah, Hyun-Dae;Sung, Shi-Joon;Cho, Ki-Yun;Jeong, Yong-Cheol;Park, Jung-Ki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.772-775
    • /
    • 2006
  • Cinnamate polymers are well known photoreactive polymers due to [2+2] cycloaddition reaction of cinnamate side group. In this work, we have found that the cinnamate side groups could be also reacted by thermal energy, and this reaction is presumed to attribute to the radical reaction of carbon double bond in the cinnamate groups. Contrary to the photocycloaddition reaction of the cinnamate side groups, the thermal reaction of cinnamate side group was closely related to the flexibility of polymer backbone. The difference of the mechanism between the photocycloaddition reaction and thermal crosslinking reaction was confirmed by $^1H-NMR$$ and $^{13}C-NMR$ analysis of the model compound.

  • PDF

Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage (태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析))

  • Kim, Y.B.;Ju, E.S.;Yun, Y.D.;La, W.J.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF

The Effect of Soil Warming on the Greenhouse Heating Load (지중가온이 온실의 난방부하에 미치는 영향)

  • Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

The Effects of Packing and Cooling Stages on the Molded Parts in Injection Molding Process (사출 성형시 보압 및 냉각 과정이 성형품에 미치는 영향)

  • 구본흥;신효철;이호상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1150-1160
    • /
    • 1993
  • The behavior of polystyrene in the strip cavity during the packing and cooling stages for an injection molding process is examined numerically. The mathematical model is based on the unified post-filling model and finite element/finite difference methods are used to solve simultaneously the continuity, momentum and energy equations coupled to an equation of state. Simulated results show that the density of the molded parts is lower in the core than at the skin, and that the hotter the melt or the higher the packing pressure, the higher the density in the core. The density variation during the packing stage comes up to 50% compared with the total density variation. Also, the density variation after gate sealing and the effect of cooling rate on the equation of state are negligible.

Computation of Turbulent Flow around Wigley Hull Using 4-Stage Runge-Kutta Scheme on Nonstaggered Grid (정규격자계와 4단계 Range-Kutta법을 사용한 Wigley선형 주위의 난류유동계산)

  • Suak-Hp Van;Hyoung-Tae Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.87-99
    • /
    • 1994
  • Reynolds Averaged Navier-Stokes equations are solved numerically for the computation of turbulent flow around a Wigley double model. A second order finite difference method is applied for the spatial discretization on the nonstaggered grid system and 4-stage Runge-Kutta scheme for the numerical integration in time. In order to increase the time step, residual averaging scheme of Jameson is adopted. Pressure field is obtained by solving the pressure-Poisson equation with the appropriate Neumann boundary condition. For the turbulence closure, 0-equation turbulence model of Baldwin-Lomax is used. Numerical computation is carried out for the Reynolds number of 4.5 million. Comparisons of the computed results with the available experimental data show good agreements for the velocity and pressure distributions.

  • PDF