• Title/Summary/Keyword: dose-response estimation

Search Result 35, Processing Time 0.021 seconds

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

Estimation of the Optimal Ratio of Standardized Ileal Digestible Threonine to Lysine for Finishing Barrows Fed Low Crude Protein Diets

  • Xie, Chunyuan;Zhang, Shihai;Zhang, Guijie;Zhang, Fengrui;Chu, Licui;Qiao, Shiyan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.8
    • /
    • pp.1172-1180
    • /
    • 2013
  • Two experiments were conducted to determine the standardized ileal digestible (SID) lysine (Lys) requirement and the ideal SID threonine (Thr) to Lys ratio for finishing barrows. In Exp. 1, 120 barrows with an average body weight of $72.8{\pm}3.6$ kg were allotted to one of six dietary treatments in a randomized complete block design conducted for 35 d. Each diet was fed to five pens of pigs containing four barrows. A normal crude protein (CP) diet providing 15.3% CP and 0.71% SID Lys and five low CP diets providing 12% CP with SID Lys concentrations of 0.51, 0.61, 0.71, 0.81 and 0.91% were formulated. Increasing the SID Lys content of the diet resulted in an increase in weight gain (linear effect p = 0.04 and quadratic effect p = 0.08) and an improvement in feed conversion ratio (FCR) (linear effect p = 0.02 and quadratic effect p = 0.02). For weight gain and FCR, the estimated SID Lys requirement of finishing barrows were 0.71 and 0.71% (linear broken-line analysis), 0.79 and 0.78% (quadratic analysis), respectively. Exp. 2 was a 26 d dose-response study using SID Thr to Lys ratios of 0.56, 0.61, 0.67, 0.72 and 0.77. A total of 138 barrows weighing $72.5{\pm}4.4$ kg were randomly allotted to receive one of the five diets. All diets were formulated to contain 0.61% SID Lys (10.5% CP), which is slightly lower than the pig's requirement. Weight gain was quadratically (p = 0.03) affected by SID Thr to Lys ratio while FCR was linearly improved (p = 0.02). The SID Thr to Lys ratios for maximal weight gain and minimal FCR and serum urea nitrogen (SUN) were 0.67, 0.71 and 0.64 using a linear broken-line model and 0.68, 0.78 and 0.70 using a quadratic model, respectively. Based on the estimates obtained from the broken-line and quadratic analysis, we concluded that the dietary SID Lys requirement for both maximum weight gain and minimum FCR was 0.75%, and an optimum SID Thr to Lys ratio was 0.68 to maximize weight gain, 0.75 to optimize FCR and 0.67 to minimize SUN for finishing barrows.

Estimation of Estrogenic Activity by E-screen Assay and Stepwise Analysis of Endocrine Disruptors in Pilot Sewage Treatment Plant (파일럿 규모의 하수 처리 공정별 E-screen Assay에 의한 에스트로겐 활성과 내분비계 장애물질의 농도 평가)

  • Lee, Ji-Ho;Park, Jong-Yol;Ra, Jin-Sung;Duong, Cuong N.;Lee, Byoung-Cheun;Kim, Sang-Don
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.697-703
    • /
    • 2006
  • Endocrine disruptors were measured with GC/MS in effluents discharged from sewage treatment processes in pilot scale for the purpose of water reuse. From that analysis, we compared the removal rate of them by treatment processes. Nonylphenol was mainly detected in effluents and high concentration from 0.36 to 0.94 ${\mu}g/L$. $17{\beta}$-estradiol(E2) and $17{\alpha}$-ethynylestradiol(EE2) were detected as below the limit of detection in effluent. Endocrine disruptors were removed effectively in the range from 50 to 100% by treatment process. EC50 value($9.0{\times}10^{-3}$ M) of $17{\beta}$-estradiol(E2) by dose response curve of E-screen assay has higher than that of bisphenol A($2.736{\times}10^{-5}M$) and p-octylphenol($9.760{\times}10^{-6}$ M). These results showed that alkylphenols have lower relative estrogen potency than other estrogens such as $17{\beta}$-estradiol(E2). Calculated estrogenic activity(ng-EEQ/L) was 2 times higher than measured total estrogenic activity which estimated by E-screen assay. Moreover estrogenic activity of effluent by treatment process showed very low as below 1 ng-EEQ/L.

A Study on the Correlation between Categorization of the Individual Exposure Levels to Agent Orange and Serum Dioxin Levels Among the Korean Vietnam Veterans (베트남 참전 제대 군인의 범주화된 에이전트 오렌지 개인 폭로량과 혈청 다이옥신 측정치와의 상관성에 관한 연구)

  • Kang, Han-K.;Lim, Hyun-Sul;Cheong, Hae-Kwan;Lim, Min-Kyung;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.1
    • /
    • pp.80-88
    • /
    • 2001
  • Objectives : In an epidemiologic study on the health impact of Agent Orange exposure, the valid estimation of exposure level is the most important step. Based on recent studies, we examined the correlation between exposure levels categorized by personal exposure estimates and serum 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD, Dioxin), exploring the possibility of utilizing the exposure level as a surrogate for the estimate of exposure to agent orange. Methods : During the study period (Jan 1996-Feb 1996), blood specimens of 745 subjects taken randomly among 1,329 persons and kept frozen, were analyzed for 2,3,7,8-TCDO and six other dioxin congeners. The serum dioxin and congeners were measured in 1998 by CDC, adjusted for serum lipids. We categorized the total exposure scores into five groups based on Agent Orange exposure data collected by interview and military records. Pearson and Spearman's correlation coefficients & multiple regression analysis were used to identify the relationship of the exposure level categorized with serum concentration of 2,3,7,8-TCDD, and six other dioxin congeners. Results : Dioxin and the other congeners, except 1,2,4,6,7,8-HpCDD, showed significant correlations to exposure categories (p<0.005): 2,3,7,8-TCDD and OCDD showed positive correlations, whereas the other congeners did negative. The values of 2,3,7,8-TCDD differed according to exposure category and proportionally increased from the low exposure group to the high, a dose-response relationship, even after other possible confounding variables were adjusted for. In multiple regression analysis, age$(\beta=0.033)$, dioxin$(\beta=0.433)$, 1,2,3,7,8-PeCDD$(\beta=-0.998)$, 1,2,3,4,7,8-HxCDD$(\beta=-0.773)$, 1,2,3,6,7,8-HxCDD$(\beta=0.255)$, 1,2,3,7,8,9-HxCDD$(\beta=-3.468)$, 1,2,3,4,6,7,8-HpCDD$(\beta=0.109)$ we re found to be significantly related to the total exposure score(p<0.005). Conclusion : This study demonstrated that the use of such categorizations as a surrogate measure of agent orange exposure in identifying exposure degrees in a health impact study is valid.

  • PDF