• Title/Summary/Keyword: dose-response estimation

Search Result 35, Processing Time 0.023 seconds

Bayesian Analysis of Dose-Effect Relationship of Cadmium for Benchmark Dose Evaluation (카드뮴 반응용량 곡선에서의 기준용량 평가를 위한 베이지안 분석연구)

  • Lee, Minjea;Choi, Taeryon;Kim, Jeongseon;Woo, Hae Dong
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.3
    • /
    • pp.453-470
    • /
    • 2013
  • In this paper, we consider a Bayesian analysis of the dose-effect relationship of cadmium to evaluate a benchmark dose(BMD). For this purpose, two dose-response curves commonly used in the toxicity study are fitted based on Bayesian methods to the data collected from the scientific literature on cadmium toxicity. Specifically, Bayesian meta-analysis and hierarchical modeling build an overall dose-effect relationship that use a piecewise linear model and Hill model, where the inter-study heterogeneity and inter-individual variability of dose and effect such as gender, age and ethnicity are accounted. Estimation of the unknown parameters is made by using a Markov chain Monte Carlo algorithm based user-friendly software WinBUGS. Benchmark dose estimates are evaluated for various cut-offs and compared with different tested subpopulations with with gender, age and ethnicity based on these two Bayesian hierarchical models.

A Channel estimation for multipath channel and performance of Viterbi equalizer of high speed wireless digital communication (고속 디지털무선통신에 있어서 멀티 패스 채널 추정과 비터비 등화기 의 동작특성)

  • 박종령;박남천;주창복
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.53-57
    • /
    • 2002
  • Recently, digital communication system becomes high speed, as communication demand dose not only increases sharply, but an image, voice various kinds data also comes multimedia. In transmitting data at a high speed, the main problem is fading by multipath. A linear or nonlinear distortion arise In multipath channel fading from ISI(Intersymbol Interference). For restoring this distorted signal, A lot of equalizer and adaptive algorithm is introduced. This paper compares and analysises, for improving communication quality in channel which is long delay spread, performance of decision feedback equalizer by RLS algorithm, a channel estimation by RLS-MLSE and viterbi equalizer Particularly, there Is exactly channel estimation of impluse response and excellent property of equalization about channel, which delay spread is long impluse response comparatively and is property of non-minimun phase.

  • PDF

Risk Assessment for Toluene Diisocyanate and Respiratory Disease Human Studies

  • PARK, Robert M.
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.174-183
    • /
    • 2021
  • Background: Toluene diisocyanate (TDI) is a highly reactive chemical that causes sensitization and has also been associated with increased lung cancer. A risk assessment was conducted based on occupational epidemiologic estimates for several health outcomes. Methods: Exposure and outcome details were extracted from published studies and a NIOSH Health Hazard Evaluation for new onset asthma, pulmonary function measurements, symptom prevalence, and mortality from lung cancer and respiratory disease. Summary exposure-response estimates were calculated taking into account relative precision and possible survivor selection effects. Attributable incidence of sensitization was estimated as were annual proportional losses of pulmonary function. Excess lifetime risks and benchmark doses were calculated. Results: Respiratory outcomes exhibited strong survivor bias. Asthma/sensitization exposure response decreased with increasing facility-average TDI air concentration as did TDI-associated pulmonary impairment. In a mortality cohort where mean employment duration was less than 1 year, survivor bias pre-empted estimation of lung cancer and respiratory disease exposure response. Conclusion: Controlling for survivor bias and assuming a linear dose-response with facility-average TDI concentrations, excess lifetime risks exceeding one per thousand occurred at about 2 ppt TDI for sensitization and respiratory impairment. Under alternate assumptions regarding stationary and cumulative effects, one per thousand excess risks were estimated at TDI concentrations of 10 - 30 ppt. The unexplained reported excess mortality from lung cancer and other lung diseases, if attributable to TDI or associated emissions, could represent a lifetime risk comparable to that of sensitization.

Analytical Consideration of Surface Dose and Kerma for Megavoltage Photon Beams in Clinical Radiation Therapy

  • Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Razmjoo, Sasan;Zabihzadeh, Mansour;Fatahiasl, Jafar;Maskni, Reza;Abdalvand, Neda;Asgarian, Zeynab;Shamsi, Azin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.153-157
    • /
    • 2016
  • Background: In radiation therapy, estimation of surface doses is clinically important. This study aimed to obtain an analytical relationship to determine the skin surface dose, kerma and the depth of maximum dose, with energies of 6 and 18 megavoltage (MV). Materials and Methods: To obtain the dose on the surface of skin, using the relationship between dose and kerma and solving differential equations governing the two quantities, a general relationship of dose changes relative to the depth was obtained. By dosimetry all the standard square fields of $5cm{\times}5cm$ to $40cm{\times}40cm$, an equation similar to response to differential equations of the dose and kerma were fitted on the measurements for any field size and energy. Applying two conditions: a) equality of the area under dose distribution and kerma changes in versus depth in 6 and 18 MV, b) equality of the kerma and dose at $x=d_{max}$ and using these results, coefficients of the obtained analytical relationship were determined. By putting the depth of zero in the relation, amount of PDD and kerma on the surface of the skin, could be obtained. Results: Using the MATLAB software, an exponential binomial function with R-Square >0.9953 was determined for any field size and depth in two energy modes 6 and 18MV, the surface PDD and kerma was obtained and both of them increase due to the increase of the field, but they reduce due to increased energy and from the obtained relation, depth of maximum dose can be determined. Conclusions: Using this analytical formula, one can find the skin surface dose, kerma and thickness of the buildup region.

Development of Frequency Weighting Shape for Evaluation of Discomfort due to Vertical Whole-body Shock Vibration (수직방향 전신 충격진동의 불편함 평가를 위한 주파수가중곡선 개발)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.658-664
    • /
    • 2006
  • Shock vibrations are usually experienced in vehicles excited by impulsive input, such as bumps. The frequency weighting functions of the current standards in ISO 2631 and BS 6841 are to help objectively predict the amount of discomfort of stationary vibration. This experimental study was designed to develop frequency weighting shape for shock vibration having various fundamental frequencies from 0.5 to 16Hz. The specks were produced from the response of single. degree-of-freedom model to a half-sine force input. Fifteen subjects used the magnitude estimation method to judge the discomfort of vertical shock vibration generated on the rigid seat mounted on the simulator. The magnitudes of the shocks, expressed in terms of both peak-to-peak value and un-weighted vibration dose values (VDVs) , were correlated with magnitude estimates of the discomfort. The frequency weighting shapes from the correlation were developed and investigated having nonlinearity due to the magnitude of the shock.

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

Estimation of Relative Biological Effectiveness for Carbon Beam

  • Onizuka, Y.;Endo, S.;Takada, M.;Ishikawa, M.;Hoshi, M.;Uehara, S.;Hayabuchi, N.;Maeda, N.;Shizuma, K.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.219-221
    • /
    • 2002
  • In this work, single event spectra were measured in order to gain the microdosimetric parameters of some heavy ion radiotherapy fields at HIMAC. Microdosimetry is now a well-established technique for the investigation of complex mixed radiation field. Changes in frequency mean lineal energy y$\_$F/ as a function of thickness of A150 phantom were obtained. The absorbed dose was obtained by using y$\_$F/. A direct relation between this single event probability distribution and relative biological effectiveness (RBE) was assumed in order to estimate RBE using the response function.

  • PDF

STUDY OF SUBJECTIVE COMFORT ON SHOCK-TYPE VERTICAL WHOLE-BODY VIBRATION (쇽타입 수직방향 전신진동에 대한 주관적 안락감에 관한 연구)

  • Ahn, Se-Jin;Griffin, M.J.;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1260-1264
    • /
    • 2006
  • Shock-type vibrations are usually experienced in vehicles excited by impulsive forces. Fifteen subjects used magnitude estimation to judge the discomfort of vertical shock-type vibration generated on a rigid seat. The shocks had different frequencies and magnitudes and were produced from the response of a 1 degree-of-freedom model to a half-sine force input. The magnitudes of the shocks, expressed in terms of both peak-to-peak value and un-weighted vibration dose values, VDVs, were correlated with magnitude estimates of the discomfort. In this study, equivalent comfort contour of shock-type vibration were obtained. From the contour, it was investigated that shock-type vibration at frequency below 0.8 Hz and between 4.0 Hz and 10.0 Hz is highly sensitive to the discomfort than at other frequencies.

  • PDF

Preliminary test estimation method accounting for error variance structure in nonlinear regression models (비선형 회귀모형에서 오차의 분산에 따른 예비검정 추정방법)

  • Yu, Hyewon;Lim, Changwon
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.4
    • /
    • pp.595-611
    • /
    • 2016
  • We use nonlinear regression models (such as the Hill Model) when we analyze data in toxicology and/or pharmacology. In nonlinear regression models an estimator of parameters and estimation of measurement about uncertainty of the estimator are influenced by the variance structure of the error. Thus, estimation methods should be different depending on whether the data are homoscedastic or heteroscedastic. However, we do not know the variance structure of the error until we actually analyze the data. Therefore, developing estimation methods robust to the variance structure of the error is an important problem. In this paper we propose a method to estimate parameters in nonlinear regression models based on a preliminary test. We define an estimator which uses either the ordinary least square estimation method or the iterative weighted least square estimation method according to the results of a simple preliminary test for the equality of the error variance. The performance of the proposed estimator is compared to those of existing estimators by simulation studies. We also compare estimation methods using real data obtained from the National Toxicology program of the United States.

Dose-Response Relationship of Avian Influenza Virus Based on Feeding Trials in Humans and Chickens (조류인플루엔자 바이러스의 양-반응 모형)

  • Pak, Son-Il;Lee, Jae-Yong;Jeon, Jong-Min
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.101-107
    • /
    • 2011
  • This study aimed to determine dose-response (DR) curve of avian influenza (AI) virus to predict the probability of illness or adverse health effects that may result from exposure to a pathogenic microorganism in a quantitative microbial risk assessment. To determine the parametric DR relationship of several strains of AI virus, 7 feeding trial data sets challenging humans (5 sets) and chickens (2 sets) for strains of H3N2 (4 sets), H5N1 (2 sets) and H1N1 (1 set) from the published literatures. Except for one data set (study with intra-tracheal inoculation for data set no. 6), all were obtained from the studies with intranasal inoculation. The data were analyzed using three types of DR model as the basis of heterogeneity in infectivity of AI strains in humans and chickens: exponential, beta-binomial and beta-Poisson. We fitted to the data using maximum likelihood estimation to get the parameter estimates of each model. The alpha and beta values of the beta-Poisson DR model ranged 0.06-0.19 and 1.7-48.8, respectively for H3N2 strain. Corresponding values for H5N1 ranged 0.464-0.563 and 97.3-99.4, respectively. For H1N1 the parameter values were 0.103 and 12.7, respectively. Using the exponential model, r (infectivity parameter) ranged from $1.6{\times}10^{-8}$ to $1.2{\times}10^{-5}$ for H3N2 and from $7.5{\times}10^{-3}$ to $4.0{\times}10^{-2}$ for H5N1, while the value was $1.6{\times}10^{-8}$ for H1N1. The beta-Poisson DR model provided the best fit to five of 7 data sets tested, and the estimated parameter values in betabinomial model were very close to those of beta-Poisson. Our study indicated that beta-binomial or beta-Poisson model could be the choice for DR modeling of AI, even though DR relationship varied depending on the virus strains studied, as indicated in prior studies. Further DR modeling should be conducted to quantify the differences among AI virus strains.