• 제목/요약/키워드: dose rate

검색결과 3,197건 처리시간 0.029초

중성자(中性子) 및 감마선(線)에 대한 선량율(線量率) 환산인자(換算因子) 계산(計算) (Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors)

  • 권석근;이수용;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제6권1호
    • /
    • pp.8-24
    • /
    • 1981
  • This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute(ANSI) N666. These data are used to calculated the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from $2.5{\times}10^{-8}$ to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoetiergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be a useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions.

  • PDF

복사전달방정식을 이용한 조사율 추정 (Estimation of dose rate using radiative transfer equations)

  • 문윤섭;김유근;이영미
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1195-1204
    • /
    • 2002
  • We calculated dose rate using radiative transfer equations to consider radiative processes distinctly. The dose rate at Pohang(36°02'N, 129°23'E) was calculated using measured ozone and meteorological data and two-stream approximations(quadrature, Eddington, delta Eddington, PIFM(practical improved flux method), discrete ordinate, delta discrete ordinate) are used in solving equation. The purpose of this study is to determine the most compatible radiative transfer approximation for simulating the radiative and photochemical processes of atmosphere through comparision between calculated and measured values. Dose rate of the biologically effective irradiance in the region 0.28-0.32 U m showed the highest value when quadrature and Eddington was used and lower value on condition that delta scaling was applied. Correlation coefficient between dose rate at surface using radiation transfer equation and measured UV-B at Pohang was 0.78, 0.79 and 0.81 when delta Eddington, PIFM and delta discrete ordinate were used. Also, in case of above approximations were used, MBE(Mean Bias Error) was within -0.3MED/30min and RMBE(Relative Mean Bias Error) was below 10% between 1200 LST and 1400 LST Approximations which are compatible in estimating radiative process are delta Eddington, PIFM and delta discrete ordinate. Especially, in case that radiative process is considered more detail, delta discrete ordinate increased the number of stream is proper.

Age or environmental radiation dose rate: Which is more correlated with cancer incidence rates in the Republic of Korea?

  • Joo, Han Young;Kim, Jae Wook;Jeong, So Yun;Choi, Jin Sik;Moon, Joo Hyun
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3452-3458
    • /
    • 2022
  • Our study adopted a big data analysis approach to determine whether there was a significant relationship between environmental radiation dose rates or age and cancer incidence rates in the Republic of Korea. The data for this analysis included environmental radiation dose rates, number of cancer patients, and age distributions of the residents from 2009 to 2016 in the administrative districts where environmental radiation monitoring posts were located. For this analysis, the environmental radiation dose rates were obtained from 171 monitoring posts located in 113 elementary administrative districts in the Republic of Korea. The number of cancer patients and the age distributions were obtained from the Central Cancer Information Center of the National Cancer Center of Korea and the Ministry of the Interior and Safety, respectively. Our findings indicated that there was no statistically significant relationship between the environmental radiation dose rate and the cancer incidence rate. However, age had a considerable influence on the cancer incidence rate of the monitored regions.

자궁 경부암 고선량율 강내조사 치료의 국내 현황과 적정 치료방법 (Current Status of High Dose Rate Brachytherapy in Cervical Cancer in Korea and Optimal Treatment Schedule)

  • 허승재
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.357-366
    • /
    • 1998
  • Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week. 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4.1 Gy each to Point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as. 78-86$\%$ for Stage 1, 68-85$\%$ for stage 11, and 38-56$\%$ for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In addition, standardization of HDR application (clinical, computer algorithms, and dosimetric aspects) is necessary.

  • PDF

Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Jinsung;Kim, Kum Bae;Yoo, Jaeryong;Ahn, So Hyun;Kim, Dong Wook;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: During the treatments of cancer patients with a linear accelerator (LINAC) using photon beams with energies ≥8 MV, the components inside the LINAC head get activated through the interaction of photonuclear reaction (γ, n) and neutron capture (n, γ). We used spectroscopy and measured the dose rate for the LINAC in operation after the treatment ended. Methods: We performed spectroscopy and dose rate measurements for three units of LINACs with a portable high-purity Germanium (HPGe) detector and a survey meter. The spectra were obtained after the beams were turned off. Spectroscopy was conducted for 3,600 seconds, and the dose rate was measured three times. We identified the radionuclides for each LINAC. Results: According to gamma spectroscopy results, most of the nuclides were short-lived radionuclides with half-lives of 100 days, except for 60Co, 65Zn, and 181W nuclides. The dose rate for three LINACs obtained immediately in front of the crosshair was in the range of 0.113 to 0.129 µSv/h. The maximum and minimum dose rates measured on weekends were 0.097 µSv/h and 0.092 µSv/h, respectively. Compared with the differences in weekday data, there was no significant difference between the data measured on Saturday and Sunday. Conclusions: Most of the detected radionuclides had half-lives <100 days, and the dose rate decreased rapidly. For equipment that primarily used energies ≤10 MV, when the equipment was transferred after at least 10 minutes after shutting it down, it is expected that there will be little effect on the workers' exposure.

과배란유도에서 GnRH Antagonist (Cetrorelix) Single 및 Multiple Dose Protocol의 임상적 효용성에 관한 연구 (A Study of Clinical Efficacy of GnRH Antagonist (Cetrorelix) Single and Multiple Dose Protocol for Controlled Ovarian Hyperstimulation)

  • 고상현;김동호;배도환;이상훈
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제29권4호
    • /
    • pp.259-267
    • /
    • 2002
  • Objective: This study was performed to compare the clinical outcomes of GnRH antagonist (Cetrorelix) single dose and multiple dose protocols for controlled ovarian hyperstimulation with GnRH agonist long protocol. Materials and Method: From September 2001 to March 2002, 48 patients (55 cycles) were performed controlled ovarian hyperstimulation for ART using by either GnRH antagonist and GnRH agonist. Single dose of 3 mg GnRH antagonist was administered in 15 patients (17 cycles, single dose group) at MCD #8 and multiple dose of 0.25 mg of GnRH antagonist was administered in 15 patients (18 cycles, multiple dose group) from MCD #7 to hCG injection day. GnRH agonist was administered in 18 patients (20 cycles, control group) by conventional GnRH agonist long protocol. We compared the implantation rate, number of embryos, and clinical pregnancy rate among three groups. Student-t test and Chi-square were used to determine statistical significance. Statistical significance was defined as p<0.05. Results: There were no significant differences in ampules of used gonadotropins, number of mature oocytes, obtained embryos between single and multiple dose group, but compared with control group, ampules of used gonadotropins, number of mature oocytes, obtained embryos were decreased significantly in both groups. Clinical pregnancy rate and implantation rate were not different in three groups. There were no premature LH surge and ovarian hyperstimulation syndrome in three groups. Multiple pregnancy were occurred 1 case in multiple dose group and 2 case in control group. Conclusions: GnRH antagonist is a safe, effective, and alternative method in the controlled ovarian hyperstimulation compared with GnRH agonist. Clinical outcomes and efficacy of both single and multiple dose protocol are similar between two groups.

원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사 (Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.55-64
    • /
    • 1998
  • 고선량률 원격 강내조사 선원은 전량 외국에서 수입되어 왔으며, 최근 Co-60 소선원의 공급부진으로 초기 도입시의 치료시간에 비해 4내지 5배의 시간을 조사하게 되어 대체용 선원의 개발이 크게 요구되고 있다. 이 연구는 국내 하나로 원자로의 중성자를 이용하여 $^{191}$ Ir(n,Υ)$^{192}$ Ir 핵반응을 일으켜 Ir-192 선원 2.87 Ci (밀봉 1.012 Ci)를 생산하고, 고선량률 원격 강내조사선원의 선량특성을 조사하였다. 제작선원에 대한 조사선량률은 아크릴 지지체의 중앙에 아크릴 아프리케이터를 고정하고 선원의 중심으로부터 각각 5, 10, 20 cm 거리에 전리함을 설치하여 일정시간 선원을 노출시켜 측정한 결과 6.36 $\pm$ 0.147 Rm$^2$/GBq-hr (2.350 $\pm$ 0.054 R$cm^2$/mCi-hr)을 결정하였으며, 측정오차는 1$\sigma$ 는 2.2% 였다. 계산선량은 조사선량률 상수 4.69 R$cm^2$/h-mCi 와 Ir-192 에너지 스펙트럼을 이용한 선원자체 및 철에 대한 질량흡수계수를 통해 구했으며, 실제 측정선량과 평균 3.8 % 오차범위에서 일치하였다. 선량 등방성은 선원의 측방향과 축 및 대각선방향으로 전리함을 이용하여 측정한 결과 3 % 이내 균등한 선량을 나타내었으며, 필름선량에서도 균등선량분포를 확인할 수 있었으며, Co-60 선원과 유사한 선량분포를 얻었을 수 있었다. 특히 본 연구의 선량특성조사는 강내조사선량선원 대체용의 선원개발과 선량계획 전산화의 근거가 될 것으로 믿는다.

  • PDF

CHANGES IN BODY AND ORGAN WEIGHTS, HEMATOLOGICAL PARAMETERS, AND FREQUENCY OF MICRONUCLEI IN THE PERIPHERAL BLOOD ERYTHROCYTES OF ICR MICE EXPOSED TO LOW-DOSE-RATE $\gamma$-RADIATION

  • Kang, Yu-Mi;Shin, Suk-Chul;Jin, Young-Woo;Kim, Hee-Sun
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.102-106
    • /
    • 2009
  • We exposed ICR mice to low-dose (0.2 Gy) and low-dose-rate (0.7 mGy/h) $\gamma$-radiation ($^{137}Cs$) in the Low-dose-rate Irradiation Facility at the Radiation Health Research Institute to evaluate systemic effects of low-dose radiation. We compared the body and organ weights, number of blood cells (white and red blood cells and platelets), levels of biochemical markers in serum, and frequency of micronuclei in polychromatic erythrocytes between low-dose irradiated and non-irradiated control mice. The ICR mice irradiated with total doses of 0.2 and 2 Gy showed no changes in body and organ weights, number of blood cells (white and red blood cells), or frequency of micronuclei in the polychromatic erythrocytes of peripheral blood. However, the number of platelets (P = 0.002) and the liver weight (P < 0.01) were significantly increased in mice exposed to 0.2 and 2 Gy, respectively. These results suggest that a low-dose-rate of 0.7 mGy/h does not induce systemic damage. This dose promotes hematopoiesis in the bone marrow microenvironment and the proliferation of liver cells. In the future, the molecular biological effects of lower doses and dose rates need to be evaluated.

재생과 증식에 기인하는 선량률 효과 (Dose-Rate Effects Generated from Repair and Regeneration)

  • 이본녕;조관호;막스 리차드;김재호
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.171-183
    • /
    • 1989
  • Roesch의 생존 방정식속에 세포증식으로 일어나는 생존증가를 가장 일반적 형식으로 포함시킨 식을 유도하고 이 식으로부터 저선량률 방사선에만 적용되는 동결과선량식 (Isoeffect formula)을 유도하였다. 이 저선량률식이 파라메터 하나로 결정해주는 총선량은 Paterson과 Green에 의하여 얻어진 실험 임상결과와 일치한다. 이 파라메터와 선량률 효과 사이의 관계의 의의를 논하였다. 또한 고선량률 분절(fractionation) 치료와 동저선량률 계속치료를 연락하는 동결과 선량식을 유도 사용하여, Ellis가 잰 실험결과와 비교하였다. 그 결과, Ellis와 Paterson이 쓴 'tolerance'의 표준이 $\alpha/\beta$의 비 4Gy에 해당하는 것임이 밝혀졌다. 그러므로 이들의 'tolerance'의 표준은 'early effect'에만 두고 본 것이 아님을 알 수 있다. 개념적인 면에서도, 아래와 같은 새로운 견해가 나올 수 있다. KHT sarcoma의 생존선도 (survival curve)에 선량률 효과가 보이지 않는 이유로 $\alpha/\beta$의 비가 큰 점을 들을 수 있다. 이것은 이 survival curve에 어께 (shoulder)가 보이지 않는 것으로도 증명이 된다. Pierquin이 선량률에 무관하게 head and neck tumor치료에 같은 총선량을 쓴 것을 정당화시킬 수 있다.

  • PDF

Improvement of doses rate prediction using the Kalman Filter-based algorithm and effective decay constant correction

  • Cheol-Woo Lee;Hyo Jun Jeong;Sol Jeong;Moon Hee Han
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2659-2665
    • /
    • 2024
  • This study proposes an algorithm that combines a Kalman Filter method with effective decay constant correction to improve the accuracy of predicting radiation dose rate distribution during emergencies. The algorithm addresses the limitations of relying solely on measurement data by incorporating calculation data and refining the estimations. The effectiveness of algorithm was assessed using hypothetical test scenarios, which demonstrated a significant improvement in the accuracy of dose rate prediction compared to the model predictions. The estimates generated by the algorithm showed a good agreement with the measured data, and the discrepancies tend to decrease over time. Furthermore, the application of the effective decay constant correction accelerated the reduction of prediction errors. In conclusion, it was confirmed that the combined use of the Kalman filter method and effective decay constant correction is an effective approach to improve the accuracy of dose rate prediction.