• 제목/요약/키워드: dose limit

검색결과 410건 처리시간 0.034초

Development of Internal Dose Assessment Procedure for Workers in Industries Using Raw Materials Containing Naturally Occurring Radioactive Materials

  • Choi, Cheol Kyu;Kim, Yong Geon;Ji, Seung Woo;Koo, Boncheol;Chang, Byung Uck;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.291-300
    • /
    • 2016
  • Background: It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. Materials and Methods: The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. Results and Discussion: The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are $10Bq{\cdot}g^{-1}$ for $^{40}K$ and $1Bq{\cdot}g^{-1}$ for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups ( < 0.1 mSv, 0.1-0.3 mSv, and > 0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels ( < 0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and > 1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. Conclusion: The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산 (A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center)

  • 이창우;이정호
    • Journal of Radiation Protection and Research
    • /
    • 제15권2호
    • /
    • pp.75-85
    • /
    • 1990
  • Kalsruhe원자력 연구소(KfK) 주변의 방사능 측정자료로부터 피폭선량을 계산하였다. 식물성 식품의 섭취가 가장 중요한 피폭 경로였고, 식품중의 자연방사성 동위원소인 K-40 과 Pb-210이 주요 피폭원이었다. 인공방사능에의한 피폭은 대부분 지표에 침척된 Cs-134 와 Cs-137으로부터 방출되는 감마선 때문이었다. KfK주변환경에서의 유효선량당량은 ICRP의 권고제한치보다 훨씬 적은 값이었다.

  • PDF

Sensitivity Analysis on the Priority Order of the Radiological Worker Allocation Model using Goal Programming

  • Jung, Hai-Yong;Lee, Kun-Jai
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.577-582
    • /
    • 1998
  • In nuclear power plant, it has been the important object to reduce the occupational radiation exposure (ORE). Recently, the optimization concept of management science has been studied to reduce the ORE in nuclear power plant. In optimization of the worker allocation, the collective dose, working time, individual dose, an total number of worker must be considered and their priority orders must be thought because the main constraint is necessary for determining the constraints variable of the radiological worker allocation problem. The ultimate object of this study s to look into the change of the optimal allocation of the radiological worker as priority order changes. In this study, the priority order is the characteristic of goal programming that is a kind of multi-objective linear programming. From a result of study using goal programming, the total number of worker and collective dose of worker have changed as the priority order has changed and the collective dose limit have played an important role in reducing the ORE.

  • PDF

생식독성과 Benchmark Dose를 활용한 Endosulfan의 노출허용수준 산출 (Estimating Permissible Intake Level for Endosulfan Using Benchmark Dose based on Reproductive Tonicity)

  • 이효민;윤은경;염영나;황명실;양기화;신효선
    • Toxicological Research
    • /
    • 제18권1호
    • /
    • pp.65-71
    • /
    • 2002
  • A benchmark dose (BMD) approach has been evaluated us a replacement for the traditional NOAEL methodology currently being wed to assess the noncancer effects of toxicants. The endocrine disrupt-ing effect of endosulfan which showed decrement of sperm count and testicular testosterone level in animals, was currently reported. The amount of endosulfan used as pesticide in the country has been continuously increased. The aim of this study was to suggest the permissible intake level (PIL), corresponding to Accept-able Daily Intake (ADI), based on endocrine disrupting effect wing BMD. Various animal data were collected by consideration of critical effect showing endocrine disruption and an animal data for reproductive toxicity was selected. The Power model from BMD software for induction of $BMD_10$ having meaning which is the dose at the 95% lower confidence limit on a 10% response was used due to that the form of selected dose-response animal data was continuous data. The $BMD_10$ was estimated to be 0.393 mg/kg/day based on reproductive toxicity showing decrement of sperm count. The permissible intake level (PIL) was calculated by dividing the $BMD_10$ by the uncertainty factors of 100 with consideration of from animal to human and human variability. The PIL as 0.004 mg/kg/day was compared with traditional ADI as 0.006 mg/kg/day based on the incidence of marked progressive glomerulonephrosis and blood vessel aneurysm in males.

Assessment of Internal Dose by $^3H\;&\;^{14}C$ of Total Diet for Inhabitants near Wolsung Nuclear Power Plants

  • Park, G.;Lin, X.J.;Kim, W.;Kang, H.D.;Doh, S.H.;Kim, D.S.;Kim, C.K.
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.51-57
    • /
    • 2003
  • To assess the internal dose by $^3H\;&\;^{14}C$ in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and $^{14}C$ concentration in total diet was analyzed for collection region and time. TFWT, OBT and $^{14}C$ concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.855 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and $^{14}C$ is $6.10{\times}10^{-5}mSv/y,\;3.71{\times}10^{-5}mSv/y\;and\;7.08{\times}10^{-3}mSv/y$, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about $7.18{\times}10^{-3}mSv/y$, which is about 0.72% of annual effective dose limit 1 mSv/y.

방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰 (Consideration about Radiological Technology Student's Frequent Workers Exposure Dose Rate)

  • 박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.573-580
    • /
    • 2018
  • The Nuclear Safety Commission amended the Nuclear Safety Act by strengthening the safety management system for the frequent workers to the level of radiation workers. And students entering radiation management zones for testing and practical purposes are subject to frequent workers. It is inevitable that this will incur additional costs. In this paper, the validity of the amendment to the Nuclear Safety Act was to be assessed in terms of radiation protection. Study subjects are from 2014 to 2016, among university students in Seong-nam Korea and comparisons for analyses were made taking into account variables that are differences in annual, practical types, on-class and clinical practice students exposure dose. The analysis showed that exposures between on-class and clinical practice received were less than the annual dose limit of 1 mSv for the public. Then, some alternatives that excluding from frequent workers during on-class practice or mitigating the frequent workers' safety regulation for only on-class frequent workers can be considered. Optimization is how rational is the reduction in exposure dose to the costs required. Therefore, the results are hardly considered for optimization. If the data accumulated, it could be considered that the revision of the act could be evaluated and improved.

정류방식에 따른 장치의 정확도와 출력 파형의 비교 (Comparison of Accuracy and Output Waveform of Devices According to Rectification Method)

  • 이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발 (Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy)

  • 황의중;백태성;윤명근
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.23-30
    • /
    • 2014
  • 방사선치료에서는 환자 체내에 전달된 선량이 원래 의도한 데로 분포되는 지 확인하기 위하여 균질한 팬텀을 이용한 정도 관리를 치료 전에 주로 시행하고 있다. 하지만 균질한 팬텀을 이용한 정도 관리는 표면이 불규칙적이고 불균질한 인체에 대한 선량분포를 완전히 보증해 주지는 못하고 있다. 본 연구에서는 환자를 투과하는 선량의 분포를 측정하여 역으로 환자체내 선량 분포를 계산하는 투과선량 기반 체내선량 검증프로그램을 개발하였다. 투과선량은 주방사선과 산란방사선으로 이루어져 있는데, 본 연구에서는 전자포탈영상장치로 측정한 선량분포로부터 주방사선만을 이용한 간단한 식으로 환자체내선량분포를 계산하는 프로그램과 감마값 분포를 평가하여 두 선량분포를 서로 비교할 수 있는 프로그램을 개발하였다. 개발된 프로그램을 이용하여 계산한 팬텀의 등중심점을 지나는 관상면의 체내선량 분포는 치료계획시스템에서 제공하는 동일 평면의 선량분포와의 비교결과 균질팬텀에서 평균 95%, 비균질팬텀에서 81.8%의 감마통과율을 보였다.

식품의약품안전청의 치료방사선 선량보증과 측정불확도 (KFDA TLD Dose Quality Audit and Measurement Uncertainty)

  • 정희교;이현구;김귀야;양현규;임천일
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.153-156
    • /
    • 2004
  • 식품의약품안전청은 1978년 12월 방사선 분야의 국가교정검사기관으로 지정되어 현재까지 Co-60선원을 이용 치료준위 방사선측정기에 대한 교정을 수행하고 있다. 식약청의 에어커마와 물 흡수선량 측정값은 국제도량형국(BIPM)과 측정소급성을 유지하고 있으며, 교정계수의 확장불확도는 0.9 %(k=2)이다. 식약청에서는 외부방사선에 대한 선량보증의 일환으로 1999년 전리함을 이용하여 방사선치료기관의 선량측정을 수행하였으며, 2002년부터 열형광선량계(TLD)를 이용한 선량측정체계를 확립 ${\cdot}$ 운영하고 있다. TLD 판독에 대한 측정불확도는 1.6 %(k=1)이며, 측정불확도를 감안하여 선량보증의 허용한계를 ${\pm}$ 5 %로 설정하였다. TLD 판독값을 선량으로 전환하는 과정에서 선질, 비선형성, 홀더사용 등의 영향을 보정하기 위한 보정정수를 사용하였다. 2003년도 치료방사선 선량보증사업에는 53개 기관(71개 선질)이 참여하였다. 선량보증 결과 71개 선질 중63개 선질(89 %)이 1차 측정에서 허용한계를 만족하였다. 허용한계 초과기관에 대해서는 재측정을 수행하였고, 그 결과 모두 허용한계 이내의 값을 나타냄을 확인하였다.

  • PDF

5-Day Repeated Intravenous Dose Toxicity Study of a New Camptothecin Anticancer Agent CKD-602 in Rats

  • Kim, Jong-Choon;Shin, Dong-Ho;Kim, Sung-Ho;Bae, Chun-Sik;Kim, Joon-Kyum;Cha, Shin-Woo;Han, Jung-Hee;Lee, Hyun-Sook;Chung, Moon-Koo
    • Toxicological Research
    • /
    • 제20권1호
    • /
    • pp.83-88
    • /
    • 2004
  • The present study was carried out to investigate the potential adverse effects of CKD-602 by a 5-day repeated intravenous dose in Sprague-Dawley rats. The test article, CKD-602, was administered intravenously to male and female rats at dose levels of 0.07, 0.22, 0.67, 2.0 and 6.0 mg/kg/day for 5 days consecutively. Mortalities, clinical findings, and body weight changes were monitored for the 14-day period after cessation of the administration. At the end of 14-day observation period, all animals were sacrificed and complete gross postmortem examinations were performed. There were 2 and 5 treatment related deaths in the 0.67 and 2.0 mg/kg/day dose groups of both genders, respectively. Treatment related clinical signs, including hair loss, skin paleness, decreased locomotor activity, emaciation, and changes in stool were observed in a dose-dependent manner from the third day after initiation of the injection. Decrease or suppression of body weight was also observed dose-dependently in males and females of the treated groups. Gross postmortem examinations revealed a dose-dependent increase in the incidence and severity of atrophy or hypertrophy and white membrane formation in the spleen, atrophy of the thymus, diffuse white spots and paleness of the liver, paleness of the lung, kidney and adrenal gland, and dark red discoloration and dark red contents in the alimentary tract. Based on these results, it was concluded that the 5-repeated intravenous injection of CKD-602 to male and female rats resulted in increased incidence of abnormal clinical signs and death, decreased or suppressed body weight, and increased incidence of abnormal gross findings. In the present experimental conditions, the $LD_{50}$ value was 2.07 (95% confidence limit not specified) mg/kg/day in both genders and the $LD_{10}$ value was 1.72 (95% confidence limit not specified) mg/kg/day in both genders.