• Title/Summary/Keyword: dose equivalent

Search Result 528, Processing Time 0.026 seconds

Neutron Dosimetry and Monitoring in the Radiation Environment

  • Nakamura, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.51-62
    • /
    • 1989
  • The high efficiency moderated-type neutron spectrometer and doseequivalent counter were developed for the measurement of low level environmental neutrons. By using these detectors, the neutron energy spectra and dose equivalent rates due to skyshine effect were measured in the environment surrounding the accelerator facilities and also the altitude variation of cosmic ray neutrons in the aircraft flying over Japan.

  • PDF

Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron (고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動))

  • Chu, S.S.;Lee, D.H.;Choi, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.22-30
    • /
    • 1976
  • The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In $8{\sim}12MeV$ electron beams, the most marked dose is observed when the build-up layer thickness is 0.5cm and cavity volume is $2{\times}2{\times}2cm^3$. 2. The highest dose point is located under cavity when the energy is increased and cavity length is longer. 3. The cavity length at which the maximum percentage dose occurs decreases with increasing energy. 4. The highest percentage cavity doses are obtained when the energy is high, the build-up layer is thin, the thickness of the cavity is large, and the length of the cavity is approximately 1 to 3cm. 5. The doses of upper portion of cavity are less than the standard dose distribution as 5 to 10%. 6. The maximum range of electron beam are extended as much as thickness of cavity. 7. A cavity having a length of 5cm closely approximates a cavity of infinite length.

  • PDF

ESTIMATION OF OFF-SITE DOSE AND RELEASE CONCENTRATION OF RADIOACTIVE LIQUID EFFLUENTS FROM RADWASTE TREATMENT SYSTEM IN KORI 3&4

  • Kim, H.S.;Son, J.K.;Kim, K.D.;Ha, J.H.;Song, M.J.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.291-298
    • /
    • 2001
  • The designed release rate of liquid effluents from radwaste treatment system should be calculated and evaluated during normal operation, including anticipated operational occurrence and be assured that the release concentration and off-site dose at unrestricted area do not exceed the limits of regulation. The expected annual release rate and off-site dose for the currently operating nuclear power plants in Korea had been calculated and evaluated using PWR-GALE and LADTAP-II which was based on USNRC Regulatory Guide 1.109. Recently, the MOST Notice 2001-2 related to release concentration and off-site dose at unrestricted area was revised to reflect the concept of ICRP-60. It is necessary for KORI 3&4 to re-calculate the release concentration and off-site dose and to compare these results with the limits of regulation. As the results of assessment, we confirmed that the release concentrations were less than its limits of MOST Notice 2001-2 and the off-site dose at unrestricted area using K-DOSE60 was 3.61E-03 mSv/yr to the age of five for the effective dose, and 4.10E-2 mSv/yr to thyroid of the age of five for the organ equivalent dose. We also confirmed the off-site dose was within the limits of MOST Notice 2001-2. Therefore, the release concentration and off-site dose re-evaluated at unrestricted area in KORI 3&4 were well below the regulation limits of MOST Notice 2001-2.

  • PDF

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography (흉부 X선사진 농도로부터 표면선량을 산출하는 방법)

  • Kim, Jung-Min;Joon, Huo;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

Safety classification for frequently-used herbal medicines inducing toxic metabolites (독성대사체를 생성하는 다빈도사용 한약재의 안전성등급화 - 천궁, 당귀, 감초, 숙지황을 중심으로 -)

  • Park, Yeong-Chul;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.123-133
    • /
    • 2015
  • The new formular for herbal medicine-safety classification in terms of evidence-based medicine was developed and applied to evaluate various herbal medicines in the previous study. This study is aimed to evaluate the frequently-used herbal medicines inducing toxic metabolites or reactive intermediates(RI), such as Ligusticum wallichii Franch, Angelica sinensis, Glycyrrhizae Radix, Rehmanniae Radix, based on 6 safety grades calculated from human equivalent dose(HED)-based MOS(margin of safety). HED-based MOS can be explained as the ratio of theoretical ALD(approximate lethal dose) of human as $LD_1$(lethal dose of 1%)/ clinical maximum dose as $ED_{99}$(Effective dose of 99%). The herbal medicine showing the ratio less than 1 belongs to Class 1, but the herbal medicine showing the ratio more than 500 belongs to Class 6 with the lowest toxicity. As a result, they were evaluated as class 2 for Angelica sinensis and Glycyrrhizae Radix, class 3 for Ligusticum wallichii Franch and Rehmanniae Radix. These resultant grades for 4 herbal medicines were lower than the grade expected under consideration that these herbal medicines are used very frequently in oriental clinics. These low grades would be due to their ingredients which is biotransformed to toxic metabolites.

OPERATIONAL EXPERIENCE OF A TWO-DOSIMETER ALGORITHM FOR BETTER ESTIMATION OF EFFECTIVE DOSE AT KOREAN NUCLEAR POWER PLANTS

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.165-169
    • /
    • 2009
  • Two dosimeters are provided to radiation workers participating in tasks where high radiation exposure is expected during maintenance at nuclear power plants. At Korean nuclear power plants, two dosimeters are currently provided for tasks where exposure rates exceed 1 mSv/hr, the difference of equivalent dose to specific parts of the body is more than 30% and an exposure of more than 2 mSv is expected in a single task. These conditions for the provisioning of two dosimeters are based on previous field test results, and it is recommended that the dosimeters be worn on the chest and back. It was also found that the workers felt it was more convenient when they wore two dosimeters on chest and back rather than on chest and head. After the application of previous field test results to practice, it was found that the calculated effective dose for workers during radiation work was lower than the maximum dose of chest or back dosimeter by approximately 10%-30%. This performance is regarded not only to meet the international guideline but also to provide convenience for workers during radiation work.

The vortex dynamics in $Bi_2$$Sr_2$Ca$Cu_2$$O_8$single crystals unirradiated and with low-density columnar defect (저밀도 원통형 결함이 $Bi_2Sr_2CaCu_2O_8$ 단결정의 볼텍스 동역학에 미치는 영향)

  • Lee, T.W.;Lee, C.W.;Shim, S.Y.;Ha, D.H.;Kim, D.H.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.36-40
    • /
    • 2001
  • We have studied vortex dynamics in$ Bi_2$$Sr_2$$CaCu_2$O$_{8}$single crystals of unirradiated and irradiated samples by using 100 $\times$ $100\mu\textrm{m}^2$Hall sensor. Doses equivalent magnetic fields are 20 G, 100 G and 1 kG. In the magnetization measurement, a second magnetization peak (SMP) was observed in unirradiated, 20 G dose and 100 G dose samples in contrast to 1 kG dose sample. In the unirradiated sample, the SMP was observed in the range of 18 K ~ 35 K and the amplitude of the SMP decreased with increasing temperature. With increase of the irradiation dose, temperature region and sharpness of the SMP were reduced. In the magnetic relaxation measurement, we observed that the normalized relaxation rate S decreased with increasing the irradiation dose. Our results suggest that the vortex dynamics is not greatly affected by low-density columnar defects.s.

  • PDF

Determination of Derived Release Limits by the Concentration Factor Method (농축인자법에 의한 유도방출 기준 설정)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.267-278
    • /
    • 1985
  • Some kinds of methods have been applied to regulate the exposure doses by the radioactive effluents from nuclear power plants. The essential one is primary dose equivalent limit recommended by the ICRP. When the primary limit cannot be applied directly for regulation, there have been dose equivalent index in case of external exposure, or maximum permissible concentration, annual limit on intake, derived air concentration and maximum permissible body burden in case of internal exposure. But the derived limit is required from the viewpoint of discharge, for those values are inadequate to control discharge rate directly. This study was carried out to derive the release limit for the Wolsung nuclear power plant by the concentration factor method. This method is based on the assumption of steady state transfer between environment compartments.

  • PDF