• Title/Summary/Keyword: dose change

Search Result 1,512, Processing Time 0.026 seconds

Evaluation of the Dose According to the Movement of Breath During Field-in-Field Technique Treatment of Breast Cancer Patients (유방암 환자의 Field-in-Field Technique 치료 시 호흡의 움직임에 따른 선량 평가)

  • Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.561-566
    • /
    • 2018
  • Field-in-Field Technique is applied to the radiation therapy of breast cancer patients, and it is possible to compensate the difference in breast thickness and deliver uniform dose in the breast. However, there are several fields in the treatment field that result in a more complex dose delivery than a single field dose delivery. If the patient's respiration is irregular during the delivery of the dose by several fields and the change of respiration occurs, the dose distribution in the breast changes. Therefore, based on the computed tomography images of breast cancer patients, a human model was created by using a 3D printer (Builder Extreme 1000) to describe the volume in the same manner. A computerized tomography (CT) of the human body model was performed and a treatment plan of 260 cGy / fx was established using a 6-MV field-in-field technique using a computerized treatment planning system (Eclipse 13.6, Varian, USA). The distribution of the dose in the breast according to the change of the respiration was measured using a moving phantom at 0.1 cm, 0.3 cm, 0.5 cm amplitude, using a MOSOXIDE Silicon Field Effect Transistor (MOSFET, Best Medical, Canada) Were measured and compared. The distribution of dose in the breast according to the change of respiration showed similar value within ${\pm}2%$ in the movement up to 0.3 cm compared to the treatment plan. In this experiment, we found that the dose distribution in the breast due to the change of respiration when the change of respiration was increased was not much different from the treatment plan.

Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer (전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가)

  • Kwon, Kyung-Tae;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.415-421
    • /
    • 2017
  • In the case of radiation therapy for prostate cancer, a balloon infused with a certain amount of air through the anus is used to reduce rectal dose. Because of the reason, radiation therapy for prostate cancer has acquired CBCT for daily image induction. In order to maintain the anatomical structure most similar to the first CT taken before treatment, it is pretreated, but it can not be said to be perfectly consistent. In two actual treatment regimens, the volume of the bladder was measured as 45.82 cc and 63.43 cc, and the equivalent diameter was 4.4 cm and 4.9 cm. As a result of this study, the mean volume of the bladder was estimated to be 56.2 cc, 105.6 cc by 20 CBCT. The mean dose of CBCT was 1.74% and the mean Bladder mean dose was 96.67%. In case B, PTV mean dose was 4.31%, Bladder mean Dose was estimated to be 97.35%. The changes in the volume of the bladder resulted in changes in the dose of PTV and bladder. The correlation coefficient of bladder dose according to the change of bladder volume showed linearity of mean dose $R^2=-0.94$. The correlation coefficient of the PTV dose according to the volume change of the bladder showed linearity of mean dose $R^2=0.04$. It was found that the dose change of PTV was larger than that of bladder according to the change of bladder volume.

AN ELECTRON MICROSCOPIC STUDY ON THE EFFECTS OF IRRADIATION ON THE ACINAR CELLS OF RAT PAROTID GLAND (방사선조사가 백서 이하선의 선세포에 미치는 영향에 관한 전자현미경적 연구)

  • Ko Kwang Jun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.31-45
    • /
    • 1988
  • The author studied the histopathologic changes according to a single or a split dose and the time after irradiation on the acinar cells of rat parotid gland. 99 Sprague Dawley rats, weighing about l20gm, were divided into control and 3 experimental groups. In experimental groups, GroupⅠ and Ⅱ were delivered a single dose of l5Gy, 18Gy and Group Ⅲ and Ⅳ were delivered two equal split doses of 9Gy, 10.5Gy for a 4 hours interval, respectively. The experimental groups were delivered by a cobalt-60 teletherapy unit with a dose rate of 222cGy/min, source-skin distance of 50㎝, depth of l㎝ and a field size of l2×5㎝. The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and examined by light and electron microscopy. The results were as follows: 1. As the radiation dose increased and the acinar cells delivered a single dose exposure were more damaged, and the change of acinar cells appeared faster than those of a split dose exposure. 2. The histopathologic change of acinar cells appeared at 1 hour after irradiation. The recovery from damaged acinar cells appeared at 1 day after irradiation and there was a tendency that the recovery from damage of a split dose exposure was somewhat later than that of a single dose exposure. 3. Light microscope showed atrophic change of acinar cells and nucleus, degeneration and vesicle formation of cytoplasm, widening of intercellular space and interlobular space. 4. Electron microscope showed loss of nuclear membrane, degeneration of nucleus and nucleoli, clumping of cytoplasm, widening and degeneration of rough endoplasmic reticulum, loss of cristae of mitochondria, lysosome, autophagosome and lipid droplet. 5. Electron microscopically, the change of rough endoplasmic reticulum was the most prominent and this appeared at 1 hour after irradiation as early changes of acinar cells. The nuclear change appeared at 2 hours after irradiation and the loss of cristae of mitochondria was observed at 2 hours after irradiation in all experimental groups.

  • PDF

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • Jung, Sang Hoon;Yu, Jeong Il;Park, Hee Chul;Lim, Do Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.64-75
    • /
    • 2016
  • Purpose: In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. Materials and Methods: In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. Results: The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median $R^2$ of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Conclusion: Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Evaluation of Radiation Dose and Image Quality according to CT Table Height (CT 테이블 높이에 따른 방사선 선량 및 화질 평가)

  • Lee, Jongwoong;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.453-458
    • /
    • 2017
  • Computed Tomography (CT) provides information on the Diagnostic Reference Level Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP) for accurate diagnosis of patients. However, it does not provide a dose change according to the table height for the diagnostic reference level provided by the CT equipment. The purpose of this study was to evaluate the image and dose according to the table height change using phantom (PMMA: Polymethyl Methacrylate) in order to find the optimal image and the minimum dose during computed tomography examination. When examining using a 32 cm PMMA phantom with the same thickness as the abdomen of an adult, there was little change in dose with table height. However, the noise evaluation of the image caused a high fluctuation of noise depending on the table height. and in the case of the 16 cm PMMA phantom, the change of the noise was small, but the dose change was about 30%. In conclusion, the location of the patient and the center of the detector are important during computed tomography (CT) examinations. In addition, table height setting is considered to be important for examinations with optimized image and minimum dose.

Comparative study of dose due to the change of fluoroscopy pulse rate of Epidural Injection treatment time (Epidural Injection시술시 투시율 변화에 따른 선량비교연구)

  • Seo, Jeong-Beom;Oh, Dong-Hoon;Lee, Jeong-Beom;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.21-26
    • /
    • 2013
  • To be investigated and measures to reduce the medical exposure of patients to change the Epidural Injection time Fluoroscopy Pulse Rate in this study. Was conducted in 50 patients who underwent surgery Epidural Injection performed by interventional care of Konkuk University Hospital from January to April 2013. The treatment time with the change of Pulse rate, is measured in minutes fluoroscopy time, and measured the area dose (${\mu}Gym^2$) and depth dose (mGy). Using the Image J program, to measure the PSNR and SNR. The fluoroscopy time as a result surgery, there was no significance in the statistical analysis, and depth dose is 34.3 to 34.9%, was reduced from 35.8 to 38.7% the area dose. It is possible to reduce the appropriate Pulse rate, to reduce the dose without statistical analysis significance fluoroscopy time.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Comparison of Exposure dose according to the C-arm Angle Change (C-arm 각도 변화에 따른 피폭선량 비교)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.453-458
    • /
    • 2011
  • This study aimed to figure out the change of exposure dose to the radiologist according to the C-arm angle change. For the exam it was fixed with 101 kvp and 4.9mA for the exposure time with 3 seconds and 5 seconds respectively. C-arm Tube was located both under and over, then the average was taken after performing for 5 times with the change of angle from -30 degree to 0, 30, 60 and 90 degree. The detector measured in 160cm high from the position of the radiologist who operates the C-arm. The measurement was shown its highest result at -30 degree followed by 0, 30, 60, 90 from the highest order. Over tube method is higher than under tube method. Therefore, to reduce the exposure dose of the radiologist, it is required for using under tube method instead of over tube method. When the angle change is made, it is recommended to use the angle that tube is growing further apart from the radiologist. And it is also necessary to shorten exposed time as much as possible to create the same quality image and also to reduce the exposure dose.