• Title/Summary/Keyword: doppler ultrasound

Search Result 152, Processing Time 0.031 seconds

The Measurement of Blood Flow of Anterior Cerebral Artery in Premature Newborns Using Duplex Doppler Ultrasonography (이중 초음파 검사를 이용한 미숙아의 전 뇌동맥 혈류 측정)

  • Hwang, Mi-Soo;Bae, Kyeung-Kug;Lee, Jae-Kyo
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.77-84
    • /
    • 1997
  • We measured the blood flow velocity of the anterior cerebral artery via anterior fontanelle approach of fifty five preterm neonates with duplex Doppler sonography and analyzed the waveform and calculated pulsatility index, resistive index. Intracranial velocities and pulsatility indexes were increased with increasing gestational age, birth weight, and age of the neonate, but resistive indices decreased. In sick babies, characteristic resistive index increment were seen in patients with intraventricular hemorrhage, but no statistical difference was seen in patients with respiratory distress syndrome. Our results suggest that duplex Doppler sonography is a useful noninvasive means of monitoring cerebrohemodynamics in normal preterm neonates and flow change of sick babies.

  • PDF

A Case of Pulmonary Sequestration Diagnosed by Doppler Sonography (도플러초음파로 진단한 폐분리증 1례)

  • Kwon, Sung-Ho;Ha, Hyoung-Keun;Chung, Myoung-Jin;Park, Man-Sil;Bae, In-Kyu;Kim, Sang-Hoon;Ahn, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.1
    • /
    • pp.66-70
    • /
    • 2002
  • Pulmonary Sequestration is a rare congenital malformation during embryouic development which results in a cystic mass of nonfunctioning lung tissue. A diagnosis of a pulmonary sequestration has traditionally relied upon identifying the pathological arterial vessels by arteriography, computed tomography, and magnetic resonance imaging. We reported a case of pulmonary sequestration diagnosed by Doppler sonography and subsequent CT angiography. A 21-year-old-woman admitted to hospital for an investigation of recurrent pneumonia with left lower chest pain. A doppler ultrasound sonography showed an aberrant blood supply from the descending thoracic aorta to the left lower chest lesion. The pulmonary sequestration was confirmed by the subsequent CT angiograph.

Ultrasound and clinical findings in the metacarpophalangeal joint assessment of show jumping horses in training

  • Yamada, Ana Lucia M.;Pinheiro, Marcelo;Marsiglia, Marilia F.;Hagen, Stefano Carlo F.;Baccarin, Raquel Yvonne A.;da Silva, Luis Claudio L.C.
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.21.1-21.14
    • /
    • 2020
  • Background: Physical exercise is known to cause significant joint changes. Thus, monitoring joint behavior of athletic horses is essential in early disorders recognition, allowing the proper management. Objectives: The aims of this study were to determine the morphological patterns, physical examination characteristics and ultrasound findings of show jumping horses in training and to establish a score-based examination model for physical and ultrasound follow-ups of metacarpophalangeal joint changes in these animals. Methods: A total of 52 metacarpophalangeal joints from 26 horses who were initially in the taming stage were evaluated, and the horses' athletic progression was monitored. The horses were evaluated by a physical examination and by B-mode and Doppler-mode ultrasound examinations, starting at time zero (T0), which occurred concomitantly with the beginning of training, and every 3 months thereafter for a follow-up period of 18 months. Results: The standardized examination model revealed an increase in the maximum joint flexion angles and higher scores on the physical and ultrasound examinations after scoring was performed by predefined assessment tools, especially between 3 and 6 months of evaluation, which was immediately after the horses started more intense training. The lameness score and the ultrasound examination score were slightly higher at the end of the study. Conclusions: The observed results were probably caused by the implementation of a training regimen and joint adaptation to physical conditioning. The joints most likely undergo a pre-osteoarthritic period due to work overload, which can manifest in a consistent or adaptive manner, as observed during this study. Thus, continuous monitoring of young athlete horses by physical and ultrasound examinations that can be scored is essential.

The Study on the Appropriate Workforce Estimation of Clinical Technologists for Job Creation in the Field of Ultrasonic Inspection

  • Bae, Hyung-Joon;Kim, Dae-Sik;Lee, Og kyoung;Kim, Chul-Seung;Choi, Sun Young;An, Young-Hoi;Kim, Eun-Young;Kang, Kun-Woo;Jang, Jin-Yong
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.381-389
    • /
    • 2019
  • The physiological function test is the only patient contact area in the field of clinical laboratory. We need to recruit and encourage the experts due to requiring the expertise and long time for examination. However, there is currently no rule for estimating optimal workforce in the field of physiological function tests. The purpose of this study is to establish the basis of the studies for mid- to long-long term job creation in the field of ultrasound by evaluating the number of appropriate tests and appropriate workforce. We calculated the quantitative and qualitative workload for the number of appropriate tests and appropriate workforce using online questionnaire. All statistical analyses were performed using SPSS version 18.0 (SPSS Inc., Chicago, IL, USA). A total of 216 respondents were 48 (22.2%) male and 168 (77.8%) female. A total of 157 laboratories were 62 (39.5%) for echocardiography, 91 (58.0%) for the transcranial Doppler (TCD) and 4 (5.7%) for the carotid ultrasound. The mean number of appropriate tests was 10 ± 2 in the echocardiography, 9 ± 2 in TCD and 11 ± 2 in the carotid ultrasound. In addition, the number of laboratories required to recruit employees for appropriate workforce was 19 in echocardiography, 18 in TCD, and 0 in carotid ultrasound. The number of hospital required to recruit workforce were 7 primary hospitals, 22 secondary hospitals, 7 third hospitals. This study can be used as an important data as the first study at present time when the data on the workforce status and work environment of the ultrasonic laboratories is insufficient. Based on the quantitative and qualitative workloads, the number of appropriate tests and appropriate workforce can support mid- to long-long term job creation in the field of ultrasound.

Application and usefulness of Ultrasound sonography in dentistry (영상치의학에서 초음파영상의 진단과유용성)

  • Choi, Yong Suk;Seo, Yoo Kyung;Kang, Ju Hee;Oh, Song Hee;Kim, Gyu Tae;Hwang, Eui Hwan
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.778-788
    • /
    • 2017
  • Ultrasound sonography(US) is used to evaluate various diseases of oral and maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging. We report the protocol and suggest the effectiveness of US for various lesions and US-guided sialography.

  • PDF

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

An intelligent method for pregnancy diagnosis in breeding sows according to ultrasonography algorithms

  • Jung-woo Chae;Yo-han Choi;Jeong-nam Lee;Hyun-ju Park;Yong-dae Jeong;Eun-seok Cho;Young-sin, Kim;Tae-kyeong Kim;Soo-jin Sa;Hyun-chong Cho
    • Journal of Animal Science and Technology
    • /
    • v.65 no.2
    • /
    • pp.365-376
    • /
    • 2023
  • Pig breeding management directly contributes to the profitability of pig farms, and pregnancy diagnosis is an important factor in breeding management. Therefore, the need to diagnose pregnancy in sows is emphasized, and various studies have been conducted in this area. We propose a computer-aided diagnosis system to assist livestock farmers to diagnose sow pregnancy through ultrasound. Methods for diagnosing pregnancy in sows through ultrasound include the Doppler method, which measures the heart rate and pulse status, and the echo method, which diagnoses by amplitude depth technique. We propose a method that uses deep learning algorithms on ultrasonography, which is part of the echo method. As deep learning-based classification algorithms, Inception-v4, Xception, and EfficientNetV2 were used and compared to find the optimal algorithm for pregnancy diagnosis in sows. Gaussian and speckle noises were added to the ultrasound images according to the characteristics of the ultrasonography, which is easily affected by noise from the surrounding environments. Both the original and noise added ultrasound images of sows were tested together to determine the suitability of the proposed method on farms. The pregnancy diagnosis performance on the original ultrasound images achieved 0.99 in accuracy in the highest case and on the ultrasound images with noises, the performance achieved 0.98 in accuracy. The diagnosis performance achieved 0.96 in accuracy even when the intensity of noise was strong, proving its robustness against noise.

The Effect of Heat Therapy on Cutaneous Blood Flow and Skin Temperature at Pre-auricular Region (온열요법이 전이부의 표층부 혈류량과 피부 온도에 미치는 영향)

  • Kim, Su-Beom;Kim, Young-Jun;Kim, Cheul;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.401-410
    • /
    • 2005
  • The purpose of this study was to assess the effect of heat therapy on cutaneous blood flow and skin temperature at pre-auricular region. Moist heat therapy and ultrasound therapy were applied to 20 healthy subjects(male: 10, female: 10). Cutaneous blood flow and skin temperature before and after heat therapy were measured with laser doppler flowmetry and thermocouple. The results were as follows ; 1. Cutaneous blood flow and skin temperature were significantly increased after moist heat therapy and ultrasound therapy. 2. In application of moist heat therapy, cutaneous blood flow and skin temperature were more increased and maintained longer than in ultrasound therapy. 3. Before heat therapy, cutaneous blood flow and skin temperature were higher in male. 4. There was no significant gender difference in changes of cutaneous blood flow and skin temperature after heat therapy. In conclusion, both moist heat therapy and ultrasound therapy increased cutaneous blood flow and skin temperature significantly, and moist heat therapy was more effective to increase cutaneous blood flow and skin temperature and to maintain increased cutaneous blood flow and skin temperature. There was no significant gender difference in the effect of heat therapy on cutaneous blood flow and skin temperature.

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

Carotid Endarterectomy for Common Carotid Artery Stenosis Using Internal Shunt -A Report of Case- (Internal shunt를 이용한 총경동맥협착 수술치험 -1례 보고-)

  • 조용길
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.324-327
    • /
    • 1995
  • Extracranial carotid artery disease is rare and closely related to cardiovascular morbidity and mortality.We experienced one case of surgical treatment of left common carotid artery stenosis using internal shunt.The patient was 54-year-old female presented as headache and dizziness for about 2 years.On Doppler ultrasound, an atheromatous plaque was noted along the posteromedial wall of left common carotid artery resulting in luminal narrowing in about 75s of cross section area.The atheroma was resected through carotid endarterectomy, measured about 5.2cm in length. Postoperative course was uneventful and she was discharged in good condition.

  • PDF