• Title/Summary/Keyword: doppler ultrasound

Search Result 152, Processing Time 0.03 seconds

Power Doppler Sonography for the Upper Urinary Tract Infection in Children (소아 상부요로감염의 진단을 위한 출력 도풀러 초음파조영술)

  • Choi, Jung-Youn;Cho, Jae-Ho;Park, Yong-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.179-185
    • /
    • 2007
  • Backgroud : Urinary tract infection (UTI) is common in children. The available gold standard methods for diagnosis, Tc-99m dimercaptosuccinic acid (DMSA) scan and computed tomography (CT) are invasive and expensive. This study was performed to assess the role of power Doppler ultrasound (PDU) for diagnosis of acute pyelonephritis (APN). Materials and Methods : A prospective study was conducted in 25 children with aged 2 weeks to 5 years who were hospitalized with the first episode of febrile UTI suggesting acute pyelonephritis. All children were examined in the first 3-5 days of admission by PDU and Tc-99m DMSA scan. The comparison between PDU and DMSA scan was performed on the basis of patients. Results : The sensitivity and specificity of PDU for the detection of affected kidneys were 38.1% and 50.0%, and the positive predictive value and negative predictive value were 61.9% and 50.0%, respectively. Vesicoureteral refluxes (VUR) were identified in 11 patients (44.4%) and 18 kidneys (36%). The PDU and DMSA scan showed a matching perfusion defect in 23.8% and 50.0% respectively. Conclusion : These data indicate the PDU has a relatively low sensitivity and specificity for differentiating APN from lower UTI but may be a complement tool to DMSA scan for the prediction of VUR in infants and children.

  • PDF

Precautions and Suggestions for Transcranial Doppler Ultrasonography (뇌혈류초음파검사에서의 주의사항 및 제안)

  • Kun-Woo KANG;Eui-Jeong LEE;Hyun-Kyung LEE;Eun-Son LEE;Yang-Hee LIM;Hyung-Tae HAN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.219-226
    • /
    • 2023
  • Transcranial doppler ultrasonography (TCD) applies a low frequency of 2 MHz to measure the blood flow velocity and waveform within the skull. Medical technologists at several hospitals are conducting these examinations, and education is being imparted in many schools and academic societies. However, the skill of the tester is of utmost importance when performing TCD. Technicians who are conducting the procedure for the first time have trouble locating the blood vessels, and some experienced personnel are worried because too many blood vessels are present. Since this procedure does not directly look at and measure blood vessels, there are several limitations and difficulties. Therefore, this study aims to provide some help by introducing precautions and suggestions for TCD technicians conducting the test.

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

An Efficient Motion Estimation and Compensation Method for Ultrasound Synthetic Aperture Imaging (초음파 합성구경 영상을 위한 효율적인 움직임 추정 및 보상 기법)

  • 김강식;황재섭;정종섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.87-99
    • /
    • 2002
  • This paper describes a method for overcoming the motion artifacts inherent in synthetic aperture(SA) imaging. based on the investigation results as to the influence of a target motion on synthetic aperture techniques. This method uses a region-based motion compensation approach in which only the axial motion is estimated and compensated for a given region of interest(ROI) under the assumption that the whole ROI moves uniformly The estimated axial motion is calculated with a crosscorrelation(CC) method at the Point where the focused signal has the maximum energy within the ROI. We also presents a method for estimating the axial motion using the autocorrelation(AC) method that is widely used to estimate average Doppler frequency Both computer simulations and in vivo experiments show that the proposed methods can improve greatly the spatial resolution and SNR of ultrasound imaging by implementing the SA techniques for two-way dynamic focusing without motion artifacts. In addition the AC-barred motion compensation method provides almost the same results as the CC-based one, but with a dramatically reduced computational complexity.

Effect of Cellular Phone on Fetal Heart Rate Patterns

  • Jafarabadi, Mina;Jafarabadi, Ladan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.181-184
    • /
    • 2004
  • There are reports showing that electromagnetic fields (EMFs) emitted at non-thermal levels may be associated with biological alterations in target cells. In this study it is objected to assess the potential influences of EMFs produced by cellular phones on fetal heart rate. Non Stress Test (NST) is a widely used method of fetal monitoring and assessing fetal health and well-being. Sixty volunteers with uncomplicated term pregnancies were studied by a Spacelabs AM-67 Doppler ultrasound monitor. Fetal Heart Rate recordings were obtained while there were no Cellular Phone around for 10 minutes. Afterwards, all patients were exposed to EMFs for 10 minutes. NST was performed while they were holding the CP on stand-by mode and then on dialing mode, each for 5 minutes. The recordings were analyzed with respect to baseline heart rate, accelerations and decelerations. The Wilcoxon matched-pairs signed-ranks test was used to compare these variables. The results indicate that EMFs emitted by CP do not cause any demonstrable effects on baseline FHR, acceleration or deceleration.

  • PDF

관상정맥동 천정결손증 3례 보고

  • 임창영;김요한;이인성;김광택;김형묵
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.218-222
    • /
    • 1987
  • Unroofed coronary sinus syndrome is an uncommon anomaly, Unroofed coronary sinus syndrome is caused by incomplete formation of the left atriovenous fold, and it usually is associated with Left SVC. If it is not diagnosed, a residual reversed or bidirectional shunt will result, and its complications will reduce life expectancy. We experienced 3 cases of unroofed coronary sinus syndrome which combines TOF with PLSVC, partial ECD, primum type ASD. In case of Unroofed coronary sinus syndrome which combines TIF with PLSVC, preoperative diagnosis was not made. In corrective operation for TOF of this case, pump weaning was failed due to hypoxia and cardiac arrest, and he expired at operation room. At autopsy of this case, complete unroofed coronary sinus was found. In the other 2 cases, partial unroofed coronary sinus syndrome was found in operation field and corrective operation was performed successfully. We report these 3 experiences with its review. ^u ++ Noninvasive Assessment of Pressure Gradients across Prosthetic Heart Valve by Doppler Ultrasound - A comparative study of the Duromedics Bileaflet Valves in mitral position and Normal Mitral Valves -with its review.

  • PDF

Fetal heart rate estimation algorithm for real-time processing (실시간처리를 위한 태아심음 추출 알고리듬)

  • Lee, Eung-Gu;Lee, Yong-Hui;Kim, Seon-Il;Lee, Du-Su
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.96-99
    • /
    • 1994
  • Despite the simplicity of processing, a conventional autocorrelation function(ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal. the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing.

  • PDF

Unusual Pseudoaneurysm of the Dorsalis Pedis Artery after an Iatrogenic Injury

  • Lee, Yeiwon;Ryu, Han Young;Kim, Young Jin;Ku, Gwan Woo
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.213-215
    • /
    • 2018
  • Aneurysm and pseudoaneurysm of the dorsalis pedis artery (DPA) are rare vascular entities. Pseudoaneurysms of the DPA are commonly due to blunt trauma, sharp penetrating injury, fracture, or iatrogenic injury. Herein, we report the case of a patient with a rare iatrogenic pseudoaneurysm that occurred after blood sampling. The diagnosis was suspected based on palpitation of a pulsatile mass on the dorsal foot and confirmed by color Doppler ultrasound and computed tomography angiography. Surgical treatment was successfully performed by reconstruction with an autologous venous graft. The patient recovered well, with no ischemic complications.

The Development of Digital FHR Monitoring System Using PC and DSP (PC와 디지탈 신호 처리기를 이용한 디지탈 FHR 감시 장치의 개발)

  • Chung, Ji-H.;Kim, Sun-I.;Park, Moon-I.;Lee, Doo-S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.79-82
    • /
    • 1991
  • Digital FHR monitoring system based on the personal computer combined wi th the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultrasound fetal Doppler signal for digital rectification, envelope detection, autocorrealtion function calculation and its peak position detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data taransmission and on-line analysis of fetal heart rate change including on-line warning system, base-line estmation, acceleration, deceleration and variability. The advantages of PC-DSP based system can be summarized as follows: 1) Minimum hardware realization. 2) Increased flexibility. 3) Total care system.

  • PDF

A Study on The Davelopement of Electronic Fetal Heart Rate Monitoring System Using Personal Computer (개인용 컴퓨터를 이용한 전자 태아심음 감시장치의 개발에 관한 연구)

  • 정지환;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.209-214
    • /
    • 1991
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultra- sound fetal Doppler signal for digital signal conditioning, rectification, low -pass filtering, autocorrealtion function calculation and its peak detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on -line analysis of fetal heart rate change including on - line warning system, base -line estmation, acceleration, deceleration and variability. It is one of the most suitable situation to apply the DSP chip for siganl conditioning, digital filtering of ultrasound fetal Dopier signal and fetal heart rate estimation using autocorrelation technique .

  • PDF