• Title/Summary/Keyword: doppler spread

Search Result 82, Processing Time 0.016 seconds

Time-related Histopathologic Changes of Fresh Frozen Vascular Xenograft in Pig-to-goat Model (돼지-염소 모델에서 신선 동결된 이종 경동맥 이식편의 시간 경과에 따른 조직병리학적 변화)

  • Chang, Ji-Min;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.180-192
    • /
    • 2007
  • Background: As determined from the recent investigations of discordant cardiac xenotransplantation, hyperacute rejection occurs mainly at the endothelial cells in donor microvascular systems, but this does not occur at cardiac valve leaflets or at medium-to-large caliber vessels. On the basis of this background, this study was performed to look into the biocompatibility for transplantation of a middle or large diameter xenogenic blood vessel by conducting xenogenic arterial transplantation with the carotid artery in a pig-to-goat model. Material and Method: The experimental group was composed of 10 pairs of pig-to-goat combinations. They were divided into each period of 1 week, and 1, 3, 6 and 12 months. Four carotid artery grafts obtained through collection of the bilateral carotid arteries from two pigs were preserved at $-70^{\circ}C$ without other treatment, and then they were transplanted into the bilateral carotid arteries of two goats. Doppler ultrasonography was done on a periodic basis after transplantation to evaluate the patency of the grafted blood vessel. At the ends of a predetermined period, the grafts were explanted from the goats and they underwent gross examination. Hematoxylin-eosin and Masson's trichrome staining were conducted. In addition, in order to examine the immunological rejection of the grafted xenogenic blood vessel, immunohistochemical staining was conducted with T-lymphocyte indicator and von Willebrand factor. Result: Two goats at the each one-week period and the one-year period died during the experimental period because of a reason unrelated to the experimental procedure, and the remaining 8 goats survived until the end of each experiment period. On Doppler ultrasonography, unilateral carotid artery occlusion was found in a goat, whose period was specified as 3 months, among the 8 survived goats. However, the vascular patency was maintained well and there was no graft that formed aneurysms in the other goats. On gross examination, the region of vascular anastomosis was preserved well, and calcification of the grafted blood vessel was not shown. Histologically, the endothelial cells of the graft disappeared one week after transplantation, and then there was progressive spread of the recipients' endothelial cells from the anastomotic site. The reendothelialization occurred over the whole graft at one month after transplantation. The neointimal thickening and adventitial inflammation became severe by 3 months after transplantation, but this lessened at 6 months and 12 months, respectively. The rate of CD3 positive cells was very low among the infiltrated inflammatory cells. Conclusion: The fresh-frozen xenogenic artery kept its patency without being greatly influenced by xenogenic immune reaction.

Adaptive Multi-Tap Equalization for Removing ICI Caused by Transmitter Power Transient in LTE Uplink System (LTE 상향 링크 시스템에서 송신기의 전력 과도 현상에 의해 발생하는 ICI를 제거하기 위한 적응적 멀티 탭 등화 기법)

  • Chae, Hyuk-Jin;Cho, Il-Nam;Kim, Dong-Ku
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.701-713
    • /
    • 2009
  • This paper studies a method for reducing performance degradation due to losing sub-carrier orthogonality caused by power transient between physical channels in LTE uplink transmission. The pattern of inter-carrier interference(ICI) caused by power transient is different from what has been studied for doppler shift, in that its pattern occurs at front and rear sides of channels in each period of power transient. The reason of ICI's occurrence results from power difference between channels, power transient duration, multi-path channel delay spread, and numbers of sub-carrier. New criterion is proposed to find out number of taps of multi-tap equalizer enough to improve the ICI. The scheme is to determine the number of taps of multi-tap equalizer when a normalized interference or a normalized ICI is greater than a normalized noise. Simulation results show that the number of taps is flexibly adjusted according to SNR(Signal to Noise Ratio) of a received signal to improve Bit Error Rate(BER), while the complexity of the proposed scheme is reduced down to 88 percentage of the classical method.