• 제목/요약/키워드: doping test

검색결과 70건 처리시간 0.028초

CONTRIBUTION OF HANARO IRRADIATION TECHNOLOGIES TO NATIONAL NUCLEAR R&D

  • Choo, Kee Nam;Cho, Man Soon;Yang, Sung Woo;Park, Sang Jun
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.501-512
    • /
    • 2014
  • HANARO is a multipurpose research reactor located at the Korea Atomic Energy Research Institute (KAERI). Since the commencement of its operation in 1995, various neutron irradiation facilities, such as rabbit irradiation facilities, fuel test loop (FTL) facilities, capsule irradiation facilities, and neutron transmutation doping (NTD) facilities, have been developed and actively utilized for various nuclear material irradiation tests requested by users from research institutes, universities, and industries. Most irradiation tests have been related to national R&D relevant to present nuclear power reactors such as the ageing management and safety evaluation of the components. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently supported national R&D projects relevant to new nuclear systems including the System-integrated Modular Advanced Reactor (SMART), research reactors, and future nuclear systems. This paper documents the current state and utilization of irradiation facilities in HANARO, and summarizes ongoing research efforts to deploy advanced irradiation technology.

국가 바이오모니터링 프로그램을 위한 소변 중 금속류 동시분석법 개발 및 검증 (Development and Validation of the Simultaneous Analytical Method of Urinary Metals and Metalloids for the National Biomonitoring Programs)

  • 조용민;양민호;임호섭;차상원;이재익;김기훈;한상범
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.594-604
    • /
    • 2019
  • Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

Micro gadolinium oxide dispersed flexible composites developed for the shielding of thermal neutron/gamma rays

  • Boyu Wang;Xiaolin Guo;Lin Yuan;Qinglong Fang;Xiaojuan Wang;Tianyi Qiu;Caifeng Lai;Qi Wang;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1763-1774
    • /
    • 2023
  • In this study, a series of flexible neutron/gamma shielding composites are fabricated through the doping of Gd2O3 into the matrix of SEBS with (MGd2O3: MSEBS) % from 5% to 100%. Neutron transmittance test shows an exponential attenuation with the increase of areal density of Gd, in which the transmittance T ranges from 59.1440% to 35.3026%, with standard deviation less than 2.2743%, mass attenuation coefficient 𝜇m from 0.3194 cm2/g to 0.4999 cm2/g, and half value layer-HVL value from 2.4530 mm to 1.1313 mm. Shielding efficiency of the Gd2O3/SEBS composites is basically improved in comparison with that of B4C/SEBS. The transmittance T, mass/linear attenuation coefficient 𝜇m and 𝜇, HVL and effective atomic number Zeff for the shielding of γ rays (39 keV, 59 keV and 122 keV) are measured and calculated with XCOM as well as MCX programs. Finally, plots of the three dimensional relationships between transmittance, doping amount and thickness are provided to the guidance for engineering shielding design. In summary, the Gd2O3/SEBS composite is proved to be an effective flexible neutron/low energy γ rays shielding material, which could be of potential applications in the field of nuclear technology and nuclear engineering.

티로프라미드 주사제의 생물학적 동등성 평가를 위한 GC/MS 방법 (Bioequivalence Evaluation of the Tiropramide Formulation by GC/MS)

  • 명승운;김명수;김혜영;곽현태;민혜기;손동렬;홍영훈
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.221-229
    • /
    • 2001
  • 본 연구에서는 이미 허가되어 시판되고 있는 D제약의 "티로파주"(대조약, 염산티로프라미드로서 1mL당 16.67mg 함유)와 S제약의 "티램주"(시험약)이 생물학적으로 동등한지의 여부를 판정하고자 시행되었다. 두 제제를 건강한 성인 남자 16인의 지원자에게 라틴방격법에 따라서 근육 주사한 후, 고체-액체 추출법으로 추출하여, GC/MS로 티로프라미드의 혈장 중 농도를 측정하고 이로부터 최고 혈장중 농도 (Cmax), 최고 혈장중 농도 도달시간(Tmax), 혈장중 약물농도-시간 곡선하 면적(AUC)에 대하여 식품의약품안정청(이하 식약청이라 함)과 서울대학교 약학대학이 공동 개발한 분산분석 프로그램에 의하여 분산분석을 행하였다. 정량을 위한 검정 곡선의 상관계수는 $R^2=0.998$로 좋은 직선성을 나타내었고, 검출한계는 0.1ng/mL였다.

  • PDF

Characterization of Ultra Low-k SiOC(H) Film Deposited by Plasma-Enhanced Chemical Vapor Deposition (PECVD)

  • Kim, Sang-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.69-72
    • /
    • 2012
  • In this study, deposition of low-dielectric constant SiOC(H) films by conventional plasma-enhanced chemical vapor deposition (PECVD) were investigated through various characterization techniques. The results show that, with an increase in the plasma power density, the relative dielectric constant (k) of the deposited films decreases whereas the refractive index increases. This is mainly due to the incorporation of organic molecules with $CH_3$ group into the Si-O-Si cage structure. It is as confirmed by FT-IR measurements in which the absorption peak at 1,129 $cm^{-1}$ corresponding to Si-O-Si cage structure increases with power plasma density. Electrical characterization reveals that even after fast thermal annealing process, the leakage current density of the deposited films is in the order of $10^{-11}$ A/cm at 1.5 MV/cm. The reliability of the SiOC(H) film is also further characterized by using BTS test.

Characterization of behaviors using electric pulse for phase switching operation of Ge2Sb2Te5 material

  • 이현철;최두진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.322-322
    • /
    • 2016
  • Phase change memory (PCM) has attracted much attention as one of the most promising candidates for next-generation nonvolatile memory. In that regard, the purposes of the study are to propose reference of effective pulse parameter to control phase switching operation and to invest the effect of nitrogen doped in PCM materials for improved cycling stability and economic energy consumption. Switching operation of PCM is affected by electric pulse parameter and as shown in figure.1 are composed to RT(rising time), ST(setting time), FT(falling time) and the effect of these parameter was precisely investigated. Transmission electron microscope (TEM) was used to confirm fine structure and retention cycle test was conducted to confirm reliability. Finally improvement reliability and economic power consumption in quantitatively are obtainable by optimum pulse parameter and nitrogen doping in GST material. these study is related to the engineering background of other semiconductor industries and it have confirmed to possibility further applications.

  • PDF

안티몬 이온주입시 Sb2O3 빔튜닝 방법 및 모니터링 연구 (A Study on Sb2O3 Beam Tuning and Monitoring in Antimony Implantation -)

  • 김상용;최민호;김남훈;정헌상;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.476-480
    • /
    • 2004
  • The characteristics of antimony implants are relatively well-known. Antimony has lower diffusion coefficient, shorter implantation range, and smaller scattering as compared with conventional dopants such as phosphorous and arsenic. It has been commonly used in the doping of buried layer in Bi-CMOS process. In this paper, characteristics and appropriate condition of monitoring in antimony implant beam tuning using Sb$_2$O$_3$were investigated to get a reliable process. TW(Thema Wave) and R$_{s}$(Sheet Resistance) test were carried out to set up condition of monitoring for stable operation through the periodic inspection of instruction condition. The monitoring was progressed at the point that the slant of R$_{s}$ varied significantly to Investigate the variation of instruction accurately.

Optical Reactivity Modification of Titanium Oxide coatings on Ceramic filters by Nitrogen ion Implantation

  • 김형진;박재원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.90-90
    • /
    • 2010
  • We investigated the modification of optical response properties of titanium dioxide (TiO2) coatings on the ceramic water-purification filters by using ultraviolet-visible absorption spectroscopy and X-ray diffraction. The TiO2 coatings were prepared on ceramic substrate by e-beam evaporation method. These amorphous TiO2 were turned into anatase phase by heat treatment at $700^{\circ}C$ for 2 hours. The doping of N atoms into the TiO2 coatings was done by using 70KeV of N+ ion implantation with the dose of $1.0{\times}1017$ ions/cm2, followed by post-irradiation heat treatment at $550^{\circ}C$ for 2 hours. Methylene blue test of TiO2 coatings to solar irradiation showed that the post-evaporation heated TiO2 was photocatalytic and N-doped TiO2 reacted to the visible part of solar irradiation.

  • PDF

가시광 응답형 광촉매 제조와 이를 활용한 실내공기환경 개선 적용 타당성 조사 (Feasibility Study of IAQ Enhancement by Visible Light Photocatalyst)

  • 이태규;윤우석;김동형;황철순;임지훈;윤정호;김영미
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.37-40
    • /
    • 2004
  • New visible photocatalyst(Nanovis$^{(R)}$) has been synthesized to overcome the barrier of limitation of UV light utilization of current $TiO_2$ photocatalyst. It was found that red shift of absorption spectrum to 550nm was achieved. Its physical properties were characterized by XRD, BET and TEM. It is also observed that Nanovis$^{(R)}$ has a photocatalytic activity for photodegradation of Trichloroethylene under visible light irradiation. V,VII group doped into substitutional sites of $TiO_2$ has proven to be indispensable for band-gap narrowing and photocatalytic activity. These test results lead us to conclude that Nanovis$^{(R)}$ can be used for IAQ improvemen and for photocatalytic water splitting to hydrogen.

Luminescent Properties of Two-Ions Doped Phosphors for LED Application

  • Kim, Tae-Gon;Kim, Young-Sic;Im, Seoung-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.52-55
    • /
    • 2009
  • A red phosphor, $(Sr,Ca)_2P_2O_7:Eu^{2+},Mn^{2+}$, for UV-LED was synthesized under a reducing atmosphere, and its luminescent properties were investigated. The phosphor absorbs ultraviolet light at around 400 nm and efficiently emits red light at approximately 610 nm through an energy transfer from $Eu^{2+}$ to $Mn^{2+}$. Using the varied input current test for the phosphor-loaded LED lamps, it was found that the luminescent efficiency of the phosphor decreased with increasing light flux. This might be due to an increased probability of excited-state absorption and the consequent non-radiative relaxation in $Mn^{2+}$ ions in the condition of high photon influx.

  • PDF