• 제목/요약/키워드: door locations

검색결과 30건 처리시간 0.021초

유무선 네트워크기반 지하철역사 공기질 제어의 위험성 평가 (Assessment of Risk in Wireless-Wired Network Based Control of Indoor Air Quality (IAQ) in Subway Stations)

  • 최기흥
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2014
  • With increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants became an important social issue. Considering the fact that various physical variables and pollutants are related to indoor air quality (IAQ) which may cause health problem, IAQ need to be closely monitored and controlled in multiple locations in subway stations. This study is a continuation of the previous studies and delay induced in wireless-wired network is experimentally evaluated and the risk involved is assessed. In doing that, a key parameter is identified to be the network delay in different network media. Application of information-theoretic measure to assess the risk in network delay is then discussed. The idea is based on the general principles of engineering design and their applications to quantification of uncertainty in network delay. Experimental results show that more risk is involved in wireless data communication. Efficient and fast conversion of transmission data in both LonWorks/IP server and ZL converter is also noted.

지하철역사의 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가에 관한 연구 (Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality(IAQ) in Subway Stations)

  • 최기흥
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.1-6
    • /
    • 2012
  • 복잡한 지하철 역사에서 공기질은 승객의 안전과 건강을 좌우하는 중요한 요소이다. $CO_2$, VOCs먼지, 미생물 등의 농도는 역사의 여러 지점에서뿐만 아니라 원격지점에서도 감시 및 제어가 가능해야 하기 때문에 유무선 네트워크를 사용한 웹기반 감시 및 제어가 필요하다. 가상디바이스 네트워크(VDN) 개념에 근거한 원격 무선센서 네트워크와 디바이스 네트워크(LonWorks)를 IP 네트워크에 연동시키면 매우 강력한 분산 감시 및 제어 성능을 제공한다. 본 연구에서는 지하철역사내 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가를 실시하였다. 특히 유무선 네트워크의 데이터 전송과 지연특성을 평가하고 승객의 안전과 건강을 위한 핵심요소를 확인하였다.

Nonlinear response history analysis and collapse mode study of a wind turbine tower subjected to tropical cyclonic winds

  • Dai, Kaoshan;Sheng, Chao;Zhao, Zhi;Yi, Zhengxiang;Camara, Alfredo;Bitsuamlak, Girma
    • Wind and Structures
    • /
    • 제25권1호
    • /
    • pp.79-100
    • /
    • 2017
  • The use of wind energy resources is developing rapidly in recent decades. There is an increasing number of wind farms in high wind-velocity areas such as the Pacific Rim regions. Wind turbine towers are vulnerable to tropical cyclones and tower failures have been reported in an increasing number in these regions. Existing post-disaster failure case studies were mostly performed through forensic investigations and there are few numerical studies that address the collapse mode simulation of wind turbine towers under strong wind loads. In this paper, the wind-induced failure analysis of a conventional 65 m hub high 1.5-MW wind turbine was carried out by means of nonlinear response time-history analyses in a detailed finite element model of the structure. The wind loading was generated based on the wind field parameters adapted from the cyclone boundary layer flow. The analysis results indicate that this particular tower fails due to the formation of a full-section plastic hinge at locations that are consistent with those reported from field investigations, which suggests the validity of the proposed numerical analysis in the assessment of the performance of wind-farms under cyclonic winds. Furthermore, the numerical simulation allows to distinguish different failure stages before the dynamic collapse occurs in the proposed wind turbine tower, opening the door to future research on the control of these intermediate collapse phases.

CFAST를 이용한 구획실 가스화재의 디자인 화재곡선 평가 (Evaluation of Design Fire Curves for Gas Fires in a Compartment Using CFAST)

  • 백빛나;오창보;황철홍
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.7-16
    • /
    • 2018
  • 본 연구에서는 CFAST를 이용하여 구획실 가스연료 화재실험에 대한 디자인 화재곡선(Design fire curves, DF)의 예측성능을 평가하였다. 평가된 디자인 화재곡선은 이전의 연구에서 제안된 2-stage DF, Ingason이 제안한 Quadratic DF와 Exponential DF이며, 예측성능 평가를 위해 각 디자인 화재곡선을 CFAST의 입력조건으로 하여 시뮬레이션을 수행하였다. 시뮬레이션결과와 실험결과의 비교를 통해 구획실 내부의 공간평균온도와 $O_2$, $CO_2$ 농도에 대해 전반적으로 2-stage DF > Quadratic DF > Exponential DF 순으로 실험결과를 합리적으로 예측하는 것을 확인하였다. CFAST 시뮬레이션 결과를 통해서도 실험에서 보이는 구획실 내 개구부측과 내측에서의 온도와 $O_2$$CO_2$ 농도 차이를 예측할 수 없음을 명확히 확인하였다. 또한 CFAST는 구획실 가스연료 화재의 CO 농도와 하층부의 공간평균온도에 대한 예측에 한계가 있음을 확인하였다.

일부 밀폐형 무창계사에서 발생하는 PM10 및 엔도톡신의 특성 및 연관성 분석 (Relationship and Characteristics of PM10 and Endotoxin Concentrations in Windowless Poultry Houses in South Korea)

  • 김효철;신소정;김경수;정원건
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.331-341
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the concentrations and relationships of coarse particles with a diameter of 10 ㎛ (PM10) with endotoxins according to the time of measurement in windowless poultry houses. Methods: In this study, measurement was performed on ten windowless poultry houses with a vertically integrated system from July to November. PM10 was measured using personal environmental monitors and polytetrafluoroethylene (PTFE) filters with a 4 L/min-calibrated pump in selected sampling locations (two near the door and two near an exhaust fan). The endotoxin on PTFE filter was analyzed by the LAL turbidimetric method. Results: The range of geometric mean concentrations of PM10 and endotoxins for each of the 38 samples were 0.12-3.30 mg/m3 and 11.9-3553.66 EU/m3, respectively. PM10 and endotoxin concentrations varied by farm, increasing with the decrease in ventilation. The range of the coefficient of determination between PM10 and endotoxin was 0.0009-0.9249. As the atmospheric temperature decreased, it was confirmed that the concentrations of PM10 and endotoxin increased because the volume of ventilation was decreased. Conclusions: Endotoxins were more affected by time of measurement and ventilation than PM10, which means that endotoxins could be an important indicator for intervention programs for improvement of indoor environments.

건축물 전동셔터 사례 분석을 통한 추락방지 체크리스트 제안 (Suggestion of a Check List to Prevent Fall Incidents Through Case Analysis of Electric Shutters in Buildings)

  • 정영민;방홍순;김옥규
    • 한국건축시공학회지
    • /
    • 제22권3호
    • /
    • pp.259-268
    • /
    • 2022
  • 건축물 전동셔터는 국·내외에서 주기적으로 발전하고 있으며, 회사, 소방서 등 다양한 건축물에서 사용이 가능하다. 건축물 전동셔터의 다양한 기능적인 부분에는 안전을 위협하는 추락 리스크 요인이 존재하며, 그 요인을 관리할 필요가 있다. 국·내외의 기술동향 및 법적기준을 분석하고, 사고사례를 분석하여 관리가 필요한 추락 리스크 요인을 도출하였다. 추락 리스크 요인을 기준으로 국내의 건축물 전동셔터를 전수 점검하였다. 건축물 전동셔터 132개소를 전수 점검해본 결과, 부적합 부위가 91개소 발견되었으며, 전체의 69%를 차지하고 있었다. 본 연구에서는 건축물 전동셔터의 안전을 위해 전수 점검을 기준으로 건축물 전통셔터의 추락방지 체크리스트를 제안하고 표적 집단면접을 통하여 검증하였다.

이동건강검진차량에서 외부의 누설선량 측정 (Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose)

  • 한범희;한상현;모은희;김종일
    • 한국콘텐츠학회논문지
    • /
    • 제15권3호
    • /
    • pp.192-198
    • /
    • 2015
  • 이동건강 검진차량에서 검진을 받는 환자나 종사자들에 대한 피폭선량이 증가하고 있으나 차량 외부의 누설방사선량에 대한 조사는 아직도 미비하다 할 수 있다. 이에 본 연구에서 실험을 통한 결과는 다음과 같이 나타났다. 누설선량이 가장 많이 발생하는 곳은 출입문에서는 우측으로 $1.14{\pm}1.75mR/h$, X선 발생기가 근접한 측면에서는 상부로 $0.65{\pm}1.25mR/h$, X선 발생기와 떨어진 측면에서는 하부로 $0.91{\pm}1.25mR/h$, 검출기가 인접한 후면에서는 상부가 $96.98{\pm}158.88mR/h$으로 다양한 위치에서 누설선량이 나타났다. 측정 위치별로는 검출기가 인접한 후면에서 $67.48{\pm}97.03mR/h$으로 누설선량이 가장 높았다. 진단용 방사선 발생장치의 안전관리에 관한 규정에는 주당 최대누설선량이 모두 만족하였지만 후면에서의 누설선량은 시간당으로 표시될 때는 무시 못 할 누설선량이 측정되었다. 따라서 이동건강검진차량에서 외부의 누설선량은 우리가 간과해서 아니 되며 관심을 가지고 방사선 방어시설의 방어벽 누설선량 기준을 다시 평가하는 기회가 필요하며, 이동건강검진차량을 이용한 X선 촬영이 증가함에 따라 시간당 선량으로 적절한 기준을 정하기 위한 방안과 노력이 요구된다고 하겠다.

스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel)

  • 박원희;김창용;조영민
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권9호
    • /
    • pp.721-736
    • /
    • 2019
  • 본 논문에서는 대심도에 위치한 지하역사(지하 6층) 및 터널에서 화재가 발생했을 경우 제연설비 작동에 따른 연기의 거동을 측정하였다. 열풍기를 이용하여 열부력 효과를 구현한 연기발생장치를 이용하여 화재연기를 생성하였다. 화재발생 위치는 승강장 위 및 스크린도어 외부에 위치한 터널부의 승강장 위의 2가지 위치를 선정하였다. 승강장 화재발생시 승강장에 설치된 환기구를 통하여 연기가 배출되도록 하는 제연모드가 일반적인데 본 연구에서는 승강장 양단에 위치한 터널부의 환기구를 통한 배기도 같이 동작되도록 설정하여 실험을 수행하였다. 다양한 위치에서 연기농도 및 풍향풍속을 측정하였고 화면을 취득하여 연기의 이동 및 제연을 분석하였다. 승강장 내부에서 화재가 발생하였을 경우와 선로부에서 화재가 발생하였을 경우 승강장의 송풍기의 제연모드 동작과 터널의 송풍기의 배연 동작으로 인하여 연기배출이 원활하였고 화재 발생 인근 구역으로의 연기전파가 억제되었다. 본 연구에서 제시한 승강장 및 승강장 양단부의 터널에 적용되는 송풍기를 같이 운전하는 제연모드를 통하여 승강장 화재 및 화재열차 정차시 화재 연기로부터 승객들에게 보다 안전한 대피환경을 제공할 수 있을 것이다.

시·공간 데이터를 활용한 E-GEN AED의 효율적 서비스를 위한 개선방안 (A Study on the Improvement Method for Efficient Service of E-GEN AED using Time and Spatial Data)

  • 백승렬;김준현
    • 한국측량학회지
    • /
    • 제37권4호
    • /
    • pp.253-265
    • /
    • 2019
  • 본 연구에서는 E-GEN (Emergency medical-GEN) 자동심장충격기(AED: Automated External Defibrillator) 설치지점의 위치 및 세부정보 등록과 공간적 배치의 적정성 등에 대한 오류사항을 분석하여 접근성과 활용성을 고려한 효율적 운영을 위한 시 공간적인 데이터 기반의 앱이나 웹의 구축을 위한 개선방안을 제시하였다. 연구결과 첫째, 각 설치지점의 위치가 서로 균등적이지 않고 일부 지역에 밀집되어 있거나 AED 설치가 필요한 지역이 발생됨을 확인할 수 있었다. 둘째, AED의 실제 설치 위치정보와 속성정보 등 설치된 지점에 대한 정보의 입력 및 등록에 있어서 부정확한 점을 확인하였다. 셋째, 시설물 주 출입구 node와 대표 지번 node를 일직선으로 연결하도록 되어 있어 후문, 사잇길, 계단 등으로 연결되지 못하는 문제점이 발생하였다. 또한 AED 설치장소의 개방시간은 요일과 계절에 따라 다양하고 출입구는 별도 장소에 있는 관리소가 관리하고 있어 이에 대한 정보도 구축할 필요가 있는 것으로 나타났다. 따라서 이러한 문제점을 위한 개선방안으로 공간적 형평성과 접근성 향상을 위한 방안, 긴급시 정확한 거리와 시간을 실제 이동경로에 따라 제공해 주는 방안, 요일과 시간을 고려한 각각의 시설물에 대한 사용가능여부 방안에 대해 제시하였다.

전북권내 냉장·냉동식품 유통차량 온도관리 현황 (Current State for Temperature Management of Cold and Frozen Food Transportation Vehicles in Jeonbuk Province)

  • 박명수;박경진
    • 한국식품위생안전성학회지
    • /
    • 제32권2호
    • /
    • pp.107-113
    • /
    • 2017
  • 본 연구는 전북권내 냉장 냉동식품 유통차량을 대상으로 온도관리에 대한 현황을 파악하고자 중소기업 2곳과 대기업 5곳의 운송차량 총 8대를 대상으로 온도현황을 조사하였다. 냉장 냉동식품 유통차량의 실제공간상의 온도분포 조사결과, 참여 중소기업의 냉장차량과 냉동차량 평균 온도는 각각 $8.35{\pm}5.72^{\circ}C$, $-3.45{\pm}16.88^{\circ}C$이었고, 대기업의 냉장차량과 냉동차량 평균온도는 각각 $3.92{\pm}1.44^{\circ}C$, $-15.38{\pm}2.98^{\circ}C$로 중소기업 보다는 낮은 온도로 운영되는 것으로 나타났다. 냉장식품 적재함의 공간위치별 온도 차이는 평균적으로 $2.40^{\circ}C{\pm}1.45^{\circ}C$, 냉동식품 적재함은 $2.37^{\circ}C{\pm}2.52^{\circ}C$의 차이가 나타났지만 공간위치별 냉장, 냉동온도 모두 통계적으로 유의하지 않았다(p > 0.05). 냉장 냉동식품 하역에 따른 유통차량 문 개 폐 전 후의 식품 표면온도는 냉장식품의 경우 열린 직후 평균 $2.17{\pm}1.90^{\circ}C$에서 닫힌 직후 $2.72{\pm}2.36^{\circ}C$로 약 $0.55^{\circ}C$ 상승하였으며, 냉동 식품은 열린 직후 $-18.58{\pm}3.66^{\circ}C$에서 닫힌 직후 $-17.76{\pm}4.15^{\circ}C$로 약 $1.18^{\circ}C$의 온도 상승이 나타났다. 본 연구결과 냉장 냉동식품 유통차량의 공간위치별, 이동 시간별, 그리고 유통차량 문의 개 폐에 따라 다양한 온도변화가 나타날 수 있음이 확인되었다. 따라서 유통 및 이동과정 중 온도변화를 실시간으로 확인할 수 있는 온도이력(Time-Temperature History) 추적시스템 도입에 대한 현장 적용 연구가 수행되어야 할 것으로 생각된다.