• 제목/요약/키워드: dominant frequency

검색결과 1,029건 처리시간 0.025초

대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진 (Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant)

  • 방경보;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

한반도 하록 참나무류의 분포 특이성 (Distributional Uniqueness of Deciduous Oaks(Quercus L.) in the Korean Peninsula)

  • 김윤하;김종원
    • 한국환경복원기술학회지
    • /
    • 제20권2호
    • /
    • pp.37-59
    • /
    • 2017
  • The Korean peninsula belongs to the temperate forest biome dominated by many deciduous oaks. We quantitatively and qualitatively studied vertical and horizontal distributions and habitat characteristics on the major oak species such as Quercus mongolica, Q. serrata, Q. variabilis, Q. dentata, Q. aliena and Q. acutissima. A total of 5,278 samples were analyzed with a species coverage and 6 principal environmental variables extracted from public database of nationwide natural environment survey. Correlation analysis was accomplished by the CANOCO using Canonical Correspondence Analysis and the Pearson correlation coefficient using PASW Statistics. The hierarchical distribution tendency of six oaks was finalized using the Goodman-Kruskal lambda coefficient of non-metric multidimensional scaling by SYN-TAX 2000. The utmost factor on the distributional segregation of oak species was the elevation, i.e. temperature. Q. serrata and Q. mongolica show clearly a diametrical distribution patterns with zonal distribution. Q. variabilis was determined as a thermophilic and xerophilous species that is a component of not only natural pseudo-climax forest but also secondary forest. The highest frequency of the dominant forest was found Q. mongolica. Whereas, Q. serrata showed the highest frequency of individual tree but the relatively lower frequency of dominant forest, which is resulted from the original habitat loss. By the benefit of the traditional Soopjeong-E, Q. acutissima dominant forests were remained rather largely. Individuals of Q. dentata occurred horizontally nationwide, but its dominant forest was the poorest. Dominant forest of Q. aliena, which is a natural vegetation, was the most rare due to a limited potential habitat.

공동주택 변기 배수소음 저감 방안에 관한 연구 (A Study on reduction of drainage noise for water closet)

  • 김인수;고철수;문재호;한문성;심경석;이준서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.881-885
    • /
    • 2001
  • The study about a drainpipe of water closet was performed as reduction of drainage noise for water closet. The Drainage noise is composed two characteristics. One is Low frequency noise and the other is high frequency noise. Low frequency noise is dominant in the first stage and high frequency noise is dominant in the last stage. This is due to water splashing and that is caused by formation of chamber pot. In this experiment, for the purpose for reducing the noise, we choose the hollow rubber pipe element. As a result, we reduced drainage noise about 11㏈A.

  • PDF

변압기내 부분방전의 종류에 따른 초음파 신호 특성 (Characteristics of Ultrasonic Signals by Partial Discharge Types)

  • 박현수;박재도;정용기;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1897-1899
    • /
    • 2000
  • This paper describes the frequency characteristics and the number of pulse of ultrasonic signals due to partial discharge occurred at each electrode. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC(b) electrode and void electrode. As a result, the dominant frequency of ultrasonic signals generated by corona in oil and partial discharge in void was hardly changed regardless with the applied voltage, but in case of surface discharge in oil, its dominant frequency moved to low frequency with the applied voltage. The increasing rate of pulse number per second was high in order of the surface discharge in oil, the partial discharge in void, the corona in oil.

  • PDF

화력 발전용 시험연소로의 연소시험 중의 연소진동 실험(I) (Experiments of Combustion Vibration in the Pilot Furnace for Fossil Power Plant under Combustion Test (I))

  • 주영호;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.341-344
    • /
    • 2004
  • This paper presents results of test for combustion vibration in the pilot furnace for fossil power plant under combustion test. We measured static pressure variation in the pilot furnace together with air and fuel flow. From test results, it shows that vibration magnitude is affected by air and fuel flow. Also, a finite element analysis using a commercial S/W is performed to calculate acoustic mode of the pilot furnace. These results show that dominant frequency occurred is related to acoustic natural frequency of furnace. After this, it needs to be studied the relation between dominant frequency of combustion vibration and air flow rate.

  • PDF

Frequency analysis of GPS data for structural health monitoring observations

  • Pehlivan, Huseyin
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.185-193
    • /
    • 2018
  • In this study, low- and high-frequency structure behaviors were identified and a systematic analysis procedure was proposed using noisy GPS data from a 165-m-high tower in ${\dot{I}}stanbul$, Turkey. The raw GPS data contained long- and short-periodic position changes and noisy signals at different frequencies. To extract the significant results from this complex dataset, the general structure and components of the GPS signal were modeled and analyzed in the time and frequency domains. Uncontrolled jumps and deviations involving the signal in the time domain were pre-filtered. Then, the signal was converted to the frequency domain after applying low- and high-pass filters, and the frequency and periodic component values were calculated. The spectrum of the tower motion obtained from the filtered GPS data had dominant peaks at a low frequency of $1.15572{\times}10-4Hz$ and a high frequency of 0.16624 Hz, consistent with two equivalent GPS datasets. Then, the signal was reconstructed using inverse Fourier transform with the dominant low frequency values to obtain filtered and interpretable clean signals. With the proposed sequence, processing of noisy data collected from the GPS receivers mounted very close to the structure is effective in revealing the basic behaviors and features of buildings.

각기 다른 유문-십이지장의 기질적 병변 3증례에 대한 장음 측정 보고 : 장음의 주주파수를 중심으로 (Bowel Sound Recording for Structural Deformity in the Pylorus-Duodenum: Report of 3 Cases)

  • 윤상협
    • 대한한방내과학회지
    • /
    • 제36권3호
    • /
    • pp.276-283
    • /
    • 2015
  • Objectives: The purpose of this study is to report bowel sound patterns recorded in 3 diseases associated with structural deformity of the pylorus-duodenum. Methods: : Bowel sound recording is a useful non-invasive tool for the evaluation of gastrointestinal motility. However, the difficulty in manual attachment of the electronic stethoscope on the abdominal wall and noise production against bowel sound signals have prohibited its widespread use. Therefore, I developed a new apparatus that eliminates the noise; it contains a sound absorbing device and a holder for the head of stethoscope. Using the new bowel sound recording system, bowel sounds of the patients were recorded repeatedly. The endoscopic and abdominal computed tomography findings were obtained from other hospitals' medical record, and all patients were confirmed to have structural deformity in the pylorus-duodenum. The records of each patient were compared and assessed. Results: : Patients had either duodenal ulcer scar, pyloric stricture, or far advanced malignant stomach cancer, as diagnosed by the gastroscopy. Their dominant frequency of bowel sound obtained from the new system was checked more than 2 times at regular intervals. All 8 recordings in the 2 patients with duodenal ulcer scar (5 times) or pyloric stricture (3 times) showed a decrease in postprandial than fasting dominant frequency. One patient with stomach cancer showed no significant change between postprandial and fasting states at 2 recordings. Conclusions: The analysis of dominant frequency in bowel sounds can indicate the existence of pyloric obstruction that could delay gastric emptying.

Study of ground vibration induced by high-speed trains moving on multi-span bridges

  • Ju, S.H.
    • Structural Engineering and Mechanics
    • /
    • 제59권2호
    • /
    • pp.277-290
    • /
    • 2016
  • This paper investigates the ground vibration induced by high-speed trains moving on multi-span continuous bridges. The dynamic impact factor of multi-span continuous bridges under trainloads was first determined in the parametric study, which shows that the dynamic impact factor will be large when the first bridge vertical natural frequency is equal to the trainload dominant frequencies, nV/D, where n is a positive integer, V is the train speed, and D is the train carriage interval. In addition, more continuous spans will produce smaller dynamic impact factors at this resonance condition. Based on the results of three-dimensional finite element analyses using the soil-structure interaction for realistic high-speed railway bridges, we suggest that the bridge span be set at 1.4 to 1.5 times the carriage interval for simply supported bridges. If not, the use of four or more-than-four-span continuous bridges is suggested to reduce the train-induced vibration. This study also indicates that the vibration in the train is major generated from the rail irregularities and that from the bridge deformation is not dominant.

하모닉 구조를 이용한 두 명의 동시 발화 화자의 위치 추정 (Two Simultaneous Speakers Localization using harmonic structure)

  • 김현경;임성길;이현수
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2005년도 추계 학술대회 발표논문집
    • /
    • pp.121-124
    • /
    • 2005
  • In this paper, we propose a sound localization algorithm for two simultaneous speakers. Because speech is wide-band signal, there are many frequency sub-bands in that two speech sounds are mixed. However, in some sub-bands, one speech sound is more dominant than other sounds. In such sub-bands, dominant speech sounds are little interfered by other speech or noise. In speech sounds, overtones of fundamental frequency have large amplitude, and that are called 'Harmonic structure of speech'. Sub-bands inharmonic structure are more likely dominant. Therefore, the proposed localization algorithm is based on harmonic structure of each speakers. At first, sub-bands that belong to harmonic structure of each speech signal are selected. And then, two speakers are localized using selected sub-bands. The result of simulation shows that localization using selected sub-bands are more efficient and precise than localization methods using all sub-bands.

  • PDF

광역계통의 실시간해석을 위한 고속 저주파수 파라미터 추정 (Fast Estimation of Low Frequency Parameter for Real-Time Analysis in Wide Area Systems)

  • 김은주;심관식;김용구;김의선;남해곤;임영철
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1078-1086
    • /
    • 2009
  • This paper presents a Fourier based algorithm for estimating the parameters of the low frequency oscillating modes. The proposed methods estimates various parameters(frequency, damping factor, mode magnitude, phase) by fitting Fourier spectrum and phase with a damped exponential cosine function. Dominant frequency is selected by taking frequency corresponding to the peak spectrum, and damping factor is estimated using the left/right spectra of Fourier spectrum. In addition, mode magnitude is calculated by the normalized peak spectrum, and phase is estimated from spectrum phase. Also, we introduce an accuracy index in order to determine the accuracy of the estimated parameters, and the index is calculated using the deviations of the peak spectrum and the left/right spectra. The parameter estimation methods proposed in this paper include very simple arithmetical processes, so the algorithms are simple and the calculation speed is very fast. The proposed methods are applied to test functions with two dominant modes. The results show that the proposed methods are highly applicable to low frequency parameter estimation.