• Title/Summary/Keyword: dominant arm

Search Result 90, Processing Time 0.024 seconds

Test and Diagnostics Methods for Judder Vibration of the Brake System (자동차 제어장치의 져더 진동 측정 및 진단 방법)

  • 강태원;임상규
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.613-620
    • /
    • 1999
  • Brake judder{or cold judder) caused by the disc thickness variation(DTV) is investigated experimentally, This cold judder is often perceived by steering wheel vibration, brake pedal pulsation, and vehicle body vibration. In this paper, how the DTV profile affects the vibration characteristics of vehicle body is shown by order tracking analysis(OTA) and operational vibration analysis(OVA) The tri-axial vibrations are measured at the knuckle, lower rm, and the body side of the lower arm. Also, measured are the wheel speed and the detail DTV profile. The interpretations of OTA results in three directions of tested vehicle indicate the relative importance in the contribution of the run-out and the DTV to the judder vibration. Also, the OVA results show the prominent vibration amplitude of the lower arm in the direction of the vehicle movement. in which the second order of wheel speed is dominant. These results could be used to diagnose the judder problem and to establish the correction methods.

  • PDF

An Analysis of Transmitted-Vibration Characteristics by Different Wrist Posture during Grinding Tasks (그라인딩 작업시 손목자세별 국소진동 전달특성 분석)

  • Hwang, Seong-Hwan;Lee, Dong-Choon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.29-37
    • /
    • 2007
  • This study was performed to evaluate the characteristics of transmitted vibration to hand-arm system under different work posture while operating a light-weighted powered hand grinder. For the experiment, 8 different types of wrist posture (natural, unlar-flexion, radual-flexion, flexion, extension, complex posture, and etc.) and 3 types of feed force (20[N], 50[N], 70[N]) were considered. 10 male subjects were employed to polish metal plate with a hand grinder. All of them were normal and healthy with no history and symptom of the work related musculoskeletal disorders in the dominant hand. Vibration acceleration data were recorded with sampling rate, 2048[Hz]. In addition, unweighted overall R.M.S. acceleration at the tool and wrist, and transmissibility between them were used to evaluate factors from the recorded tri-axial vibration acceleration. The results indicate that transmissibility of natural wrist posture was significantly higher than others. In addition, as the feed force becomes larger, the vibration was transmitted in large quantities to hand-arm system through radius.

Measurement and Assessment of Hand-arm Vibration due to Grinders (그라인딩 작업에 의한 수완계 진동 계측 및 평가)

  • 이종문;박진화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1032-1037
    • /
    • 2003
  • This work measured the hand-transmitted vibration due to shipyard worker's grinding and assessed the vibration exposure for predicted 10% prevalence of vibration-induced white finger in a group of exposed persons according to test procedure of ISO 5349-1. And also the transmissibility performance of resilient material, mainly applied to anti-vibration gloves in present market was measured on the basis of ISO 13753 and confirmed that the material would Probably not provide greater attenuation below 30㎐, the dominant frequency range of hand-transmitted vibration due to grinder.

  • PDF

Hand-Arm Vibration and Noise Levels of Double-Hammer Type and Oil-Pulse Type Impact Wrenches in Automobile Assembly Lines (자동차 조립라인에서 이중-헴머형(Double-hammer type) 임펙트 렌치와 오일-펄스형(Oil-pulse type)임펙트 렌치 에어공구의 국소진동가속도 및 소음수준)

  • Jeung, Jae-Yeal;Kim, Jung-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.147-159
    • /
    • 1995
  • This study was conducted to introduce fundamental data of hand-arm vibration and noise exposure levels with impact wrenches(double-hammer impact wrenches and oil-pulse impact wrenches) used in automobile assembly lines considering the process variables and tool variables. In studing, products per day, required time screwing the bolts or nuts per bolts or nut were considered as process variables, and capacity of bolts or nuts, air consumptions per minute, tool weights, RPM were considered as tool variables. Hand-arm vibration levels of 3 axis in each hand were measured using the instruments compling with ISO/DIS 5349 and noise levels were measured using a noise logging dosimeter. The results were as follows : 1. Required time to screwing the bolt or nut by oil-pulse impact wrenches is shorter than double-hammer impact wrenches but total daily exposure time of oil-pulse impact wrenches was higher than double-hammer impact wrenches because the number of bolts or nuts per cycle was many. 2. Oil-pulse impact wrenches have been used to screwing the large bolt or nut in comparing with double-hammer impact wrenches and required time to screwing the bolts or nuts were shorter than double-hammer impact wrenches because oil-pulse impact wrenches were using high RPM and large air consumption per minute. Noise level of oil-pulse impact wrenches was 8 dB(A) lower than double-hammer impact wrenches. 3. Dominant hand-arm vibration levels of double-hammer impact wrenches in each hand were $8.24m/sec^2$ of Zh axis in right hand and $9.60m/sec^2$ of Xh axis in left hand. Dominant hand-arm vibration level of oil-pulse impact wrenches in each hand was $2.59m/sec^2$ of Xh axis in right hand and $3.23m/sec^2$ of Yh axis in left hand. 4. In double-hammer impact wrenches, corresponding hand-arm vibration levels of Xh, Yh, Zh axis in left hand were higher than hand-arm vibration levels of right hand in 3 axis. In oil-pulse impact wrenches, Xh axis of right, Yh axis of left, Zh axis of left were higher than the corresponding hand-arm vibration levels of Xh, Yh, Zh axis in right and left hand. 5. Correlation coefficients among Xh, Yh. Zh axis of right and left hand hand-arm vibration levels in double-hammer impact wrenches and oil-pulse impact wrenches were commonly high in Yh axis and correlation coefficients of Yh axis in double-hammer impact wrenches and oil-pulse impact wrenches were 0.76 and 0.86,respectively. 6. As a measure repetitiveness, plotting total daily exposure time with the number of bolts or nut per cycle, direct correlation was shown between repetitiveness and hand-arn vibration exposure, and correlation coefficient between the number of bolts or nut per cycle and total daily exposure time in double-hammer impact wrenches, oil-pulse impact wrenches were 0.84 and 0.50, respectively. 7. Considering the total acceleration level and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption in right hand, and bolt or nut capacity in left hand were commonly the variable that explainability was high. Considering the noise and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption per minute was commonly the variable that explainability was high.

  • PDF

A Study on Quantification of Kinesthetic Sense Using Human Sensibility Ergonomics Approach (운동감의 정량화를 위한 감성공학적 기법 개발에 관한 연구)

  • Sin, Dong-Yun;Lee, Se-Han;Song, Jae-Bok;Kim, Yong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • When grasping a movable object or making an object move, humans feel kinesthetic sense. The kinesthetic sense is the human sense that the human feels in response to the motion acted on him. The objective of the paper is to transform the kinesthetic sense associated with the human arm into the quantified data that are useful from the engineering viewpoint. A 2-dimensional motion generator composed of two linear motors was developed to provide various motion patterns. It can change its stiffness and damping values on the real-time basis by properly regulating the force generated by the linear motors. Based on Taguchi method, the most dominant factors to affect the kinesthetic sense were investigated. Also, a reference function adequate to quantify the kinesthetic sense was found. Based on this function, the effects of changes in stiffness and damping on the kinesthetic sense were investigated. Various tests show that the damping is a more dominant factor than the stiffness in forming the kinesthetic sense.

  • PDF

Effect of Ambient Air Temperature on the Pattern of Clothing Ventilation through Openings (환경 온도가 개구부를 통한 의복의 환기 양상에 미치는 영향)

  • 추미선
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.793-801
    • /
    • 2002
  • The effects of ambient air temperature on the clothing ventilation were investigated numerically by a finite difference method. Numerical analysis using a 2-dimensional model comprising the air space between the skin and the clothing was conducted under the assumption that the clothing ventilation occurred only through the openings not through the fabric. The larger the temperature difference between the skin and the surroundings, the more apparent the thermal boundary layer As the ambient air temperature decreased, the air flow and the rate of the return of oxygen concentration to the atmosphere level in the clothing increased. Convection was dominant under low ambient air temperature, whereas conduction was dominant under high ambient air temperature. The ventilation rate was faster in the clothing microenvironment of the body part than that of the arm part.

  • PDF

Approximate Multi-Objective Optimization of A Wall-mounted Monitor Bracket Arm Considering Strength Design Conditions (강도조건을 고려한 벽걸이 모니터 브라켓 암의 다중목적 근사최적설계)

  • Doh, Jaehyeok;Lee, Jongsoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.535-541
    • /
    • 2015
  • In this study, an approximate multi-objective optimization of a wall-mounted monitor bracket arm was performed. The rotation angle of the bracket arm was determined considering the inplane degree of freedom. We then formulated an optimization problem on maximum stress and deflection. Analyses of mean and design parameters were conducted for sensitivity regarding performance with orthogonal array and response surface method (RSM). RSM models of objective and constraint functions were generated using central composite (CCD) and D-optimal design. The accuracy of approximate models was evaluated through $R^2$ value. The obtained optimal solutions by non-dominant sorting genetic algorithm (NSGA-II) were validated through the finite element analysis and we compared the obtained optimal solution by CCD and D-optimal design.

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Ultrasound-guided needle decompression and steroid injection for calcific tendinitis of the shoulder: risk factors for repeat procedures and outcome analysis

  • Kim, Su Cheol;Lee, Sang Min;Park, Gun Tae;Jang, Min Chang;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.55-65
    • /
    • 2021
  • Background: Although ultrasound-guided needle decompression (US-GND) can treat calcific tendinitis of the shoulder effectively, repeat procedures might be required for unresolved symptoms. We evaluated the overall clinical outcomes of US-GND with subacromial steroid injection and the final results and factors predisposing toward repeat procedures. Methods: Ninety-eight patients who underwent US-GND for calcific tendinitis of the supraspinatus/infraspinatus were analyzed between March 2017 and December 2018. The clinical outcomes (pain visual analog scale, functional visual analog scale [FVAS], and American Shoulder and Elbow Surgeons [ASES] score) and final subjective satisfaction were compared between groups A (single US-GND) and B (repeat US-GND). The factors predisposing toward repeated US-GNDs were analyzed. Results: We found that 59.3% (58/98) of patient ASES scores were ≥80, and 73.5% of patients (72/98) were satisfied with the outcome. Group B (n=14) demonstrated a significantly higher rate of dominant-arm involvement compared to group A (78.6% vs. 48.8%, p=0.046). However, initial calcification size, shape, number, density, subscapularis involvement, lavage, and procedure time did not differ significantly between the groups. Group B showed poorer final FVAS (7 [interquartile range, 6-8] vs. 8 [interquartile range, 7-9], p=0.036) and subjective satisfaction compared to group A (satisfied: 5 [35.7%] vs. 67 [79.8%], p<0.001]. Conclusions: US-GND with subacromial steroid injection is a viable treatment option for calcific tendinitis of the shoulder. Dominant-arm involvement was the only independent factor for repeated US-GND. Final outcome of repeated US-GND for unimproved patients was promising; however, these outcomes were poor compared to those of the patients who improved after the first procedure.

Assessment of Vibration Produced by Pneumatic Hand Tools Used in Automobile Assembly (자동차 조립공정에서 공기압력식 진동공구의 국소진동평가)

  • Kim, Sun Sul;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.

  • PDF