• Title/Summary/Keyword: domestic use standards

Search Result 257, Processing Time 0.023 seconds

A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System (거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구)

  • Huh, Ye-Rim;Kim, Yoon-Seong;Kim, Hye-won;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse (물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구)

  • Hun, Ye-Rim;Kim, Yun-Seong;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF

A Study on the Temperature Environmental Test Standards (온도 환경시험 표준규격에 관한 연구)

  • Lee Kwan-Hun;Kim Joon-Won
    • Journal of Applied Reliability
    • /
    • v.5 no.2
    • /
    • pp.209-219
    • /
    • 2005
  • The required standards for environmental tests for communication and electronic equipment used currently are not standards into which the Korean climate and use environment are taken into consideration. But the most used environmental testing standards of the U.S. army(MIL-STD-810) has been used without taking into consideration the Korean domestic situation and conditions by simply translating the US standards. Adherence to these standards may increase in the manufacturing costs according to excessively strict standards. Therefore, this paper will propose a new environmental test standards for temperature.

  • PDF

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

Revision of Safety Standards through Analysis of Fatal Accidents Related to Mobile Scaffold in Construction Sites (건설현장 이동식 비계의 사망사고 분석을 통한 안전기준 개선 방안)

  • Ju Dong Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.1
    • /
    • pp.42-54
    • /
    • 2023
  • Mobile scaffold is used as a work platform in construction sites. According to industrial accident data, 10 fatalities occur annually on average due to falling from mobile scaffold in construction sites. To prevent such fatal accidents, safety standards must be improved by analyzing the causes of fatal accidents related to mobile scaffold. Accordingly, we analyzed domestic and international safety standards for mobile scaffold and analyzed the fatalities (117 persons) caused by mobile scaffold accidents in domestic construction sites during 2011-2020 and found that fall, overturn, and collapse accounted for 88% (103 persons), 10.3% (12 persons), and 1.7% (2 persons) of fatalities, respectively. The main causes of fatal accidents were found to be non-installation or insufficient installation of safety rails and outriggers and incorrect sequence of work. Based on the analysis results, we proposed strategies for improving the safety standards, such as the use of advanced guard rails and wheel-attached outriggers, to enhance the safety and field applicability of the mobile scaffold. Technology development and improvements in the safety standards for the use of mobile scaffold will aid in the prevention of fatal accidents caused by mobile scaffold.

A Study on The Korean Climatic Condition for The Military Environmental Testing Specification. (군 환경시험규격 현실화를 위한 한반도 자연환경 조건분석)

  • 이관훈;송병석;홍원식;강보철;염대원;이도희;김준원;금종주
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.70-83
    • /
    • 2001
  • The required standards for environmental tests for communication and electronic equipment used currently in the army are not standards into which the Korean climate and use environment are taken into consideration. But the environmental testing standards of the U.S. army at the time of its establishment(MIL-STD-810) “A” version has been used without taking into consideration the Korean domestic situation and conditions by simply translating the US standards. Adherence to these standards may limit the ability to supply materials in case of emergency since the increase in the manufacturing costs according to excessively strict standards induces an increase in the acquisition cost of military equipment, unnecessarily high maintenance and repair expenses are consumed, and stocks of parts for the military use have to be retained at all times.

  • PDF

A Study on the Terminology Standardization for Integrated Management System of Disaster Safety Standards

  • Chung, Sunghak;Park, Dugkeun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • The objective of this study is to suggest the templates for the terminology standardization cases of safety standard on integrated management system, so that integrated management of safety standards is introduced to replace redundant, or conflicting functions and performance of these standards. And to carry out the terminology standardization enables management efficiently. Therefore this study suggests and analyzes cases of terminology standardization of domestic and international research trends. In addition to proposes a architectural schema for disaster safety standard and writing disaster safety standardizations of the International Organization for Standardization. For the objectives, the guidelines on standard terminology policy, terminology publication and guide development proposed by the International Organization for Standardization. Disaster safety standards were applied in order to build and utilize integrated management system of disaster safety standards through domestic and foreign cases. Throughout the result of this study, this study will contribute to the analysis and application of semantic knowledge based analysis throughout the ontology information linked the vocabulary to vocabulary by making the template of the disaster safety standards for easy to use and simple etc. This study is to expect traceability for the principle national disaster safety standards resource elements.

Environmental Standards for Beneficial Uses of Dredged Materials (준설토 활용과 환경기준)

  • Yoon, Gil-Lim;Lee, Chan-Won;Jeong, Woo-Seob
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.247-258
    • /
    • 2008
  • Environmental standards for beneficial uses of dredged materials are proposed. Even though chemical analysis of ocean sediments are carried out frequently, their analyses results were not interrelated with the effects of biological lives due to a shortage of biological data. These facts have resulted in difficulty to develope Korean's standards of recycling dredged materials. This paper first searched existing current foreign standards, analyzed local contaminated ocean sediment data, identified their main chemical components of contaminants, and then compared with clean-up standards of sediments consisting of lower and higher levels. From these analysis, new environmental standards considering Korean domestic circumstances are proposed. It is judged that new standards are appropriate to both Korean national sedimental environments and economically recycling aspects because environmental standard levels proposed are higher than background levels of sediments in Korean and foreign standards.

  • PDF

A Study on the Temperature Environmental Test Standards (온도 환경시험 표준규격에 관한 연구)

  • Lee Kwan-Hun;Kim Joon-Won
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.421-430
    • /
    • 2005
  • The required standards for environmental tests for communication and electronic equipment used currently are not standards into which the Korean climate and use environment are taken into consideration. But the most used environmental testing standards of the U.S. army(MIL-STD-810) has been used without taking into consideration the Korean domestic situation and conditions by simply translating the US standards. Adherence to these standards may increase in the manufacturing costs according to excessively strict standards. Therefore, this paper will propose a new environmental test standards for temperature.

  • PDF

Improvement of Application Criteria of Pull Code Switch for Conveyor Accident Prevention (컨베이어 사고 예방을 위한 풀 코드 스위치 적용기준 개선)

  • Seo, Jae Min;Park, Ji Hoon;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.153-158
    • /
    • 2019
  • It is estimated that about 2,515 persons have been injured by conveyor for the past five years(2013 ~ 2017). Conveyors used in various industrial sites for transporting iron ore, coal, courier goods, etc., have various incidents such as a worker putting on or pulling a part of the body or work clothes on the driving part during maintenance. It is necessary for preventing similar accidents to conduct various researches. In order to propose the basis for revising laws and standards for the safety standards of the full cord switch to prevent conveyor accidents, this study compares Korea's Industrial Safety and Health Law (KISHL) with those of IEC, EN, Canada, and Australia. In addition, surveys of conveyor use plant and full cord switch domestic and foreign manufacturers was conducted. In this study, domestic and overseas related laws and technical standards compare and analyze to prevent conveyor accidents. In addition, we propose extension of safety certification for full code switch, establishment of safety inspection standard, and improvement of working method regulation through actual working condition investigation. It can be used as a basis for revising the occupational safety and health regulation and related notices, and thus contributing to enhancing the safe atmosphere of the conveyor business and improving the safety consciousness of the concerned persons.