• Title/Summary/Keyword: domestic resistance

Search Result 460, Processing Time 0.033 seconds

Osmotic fragility of erythrocyte in cattle, sheep and goats (Holstein 유우, 한우, 면양 및 한국재래산양 적혈구의 삼투적 취약성)

  • Min, Byeong-man;Lee, Bang-whan
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.1
    • /
    • pp.29-33
    • /
    • 1990
  • The study was attempted to scrutinize the normal osmotic fragility of erythrocyte in the domestic ruminants, making a comparison with that of human and canine. The animals used in the experiment were apparently healthy adult Holstein cattle, Korean native cattle, sheep (Corriedale) and Korean native goats. Osmotic fragility of erythrocytes was the highest in the Korean native goats, and the next were sheep and Korean native cattle, and Holstein cattle in order. In other words, erythrocytic resistance to osmotic lysis was the strongest in Holstein cattle and the most weak in Korean native goats among the domestic ruminants. In general, resistance of erythrocytes was stronger in human and canine than in the domestic ruminants.

  • PDF

The Study on the Basic Properties of Concrete Containing the Domestic Artificial Lightweight Aggregate (국내산 인공경량골재를 이용한 콘크리트의 기초 특성 연구)

  • Kwon, Hae-Won;Seo, Hui-Wan;Lee, Ji-Hwan;Jun, Woo-Chul;Lee, Jae-Sam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.32-33
    • /
    • 2013
  • This study was a result of laboratory test to confirm the porperties of concrete containing the domestic artificial lightweight aggregate. The domestic artificial lightweight aggregate is made with bottom ash which waste material in the thermal power plant. In the experimental result air contents of fresh concrete was measured lower than other artificial lightweight aggregate. This air contents is important for retaining the resistance of freezing and thawing. Therefore air contents of concrete will be considered for retaining the resistance of freezing and thawing when manufacture the concrete containing the domestic artificial aggregate.

  • PDF

A Development of the Humidity Sensor and Controller Using High Frequency Resistance Method for Hopper-Scale (호퍼스케일용 고주파 저항방식의 습도센서 및 컨트롤러 개발)

  • 서양오;이창근;이동철;홍연찬
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.163-166
    • /
    • 2000
  • This paper describes the principle of humidity sensor using high frequency resistance method for Hopper-Scale that is used in RPC(Rice processing Complex) which is spreaded out in domestic, and we also understand the principle and specificity of controller and humidity sensor. After artworking the humidity sensor and controller circuit, we measure the humidity of the designed system. In this progress, we suggested substitute parts which are easy to get in domestic and also we could propose correct method of humidity detection.

  • PDF

A comparative Study on the Fire Resistance Design Standard of Buildings (한국 건축법 방화관련 규정의 변천과정에 관한 문헌적 고찰)

  • Kim, Se-Jong;Lee, Jae-Young;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.353-356
    • /
    • 2008
  • Recently, high-rise buildings have been increased with the development of economy in domestic, and theses fire riskiness has been brought up. However, fireproof design standards is not enough. So, this study was to make a comparative study on the fire resistance design standards of building in domestic and foreign. As a results, it is necessary that fireproof design standards is revised.

  • PDF

Reliability Analysis of Concrete Road Bridge Designed with Different Resistance Factor Format (콘크리트 도로교 설계를 위한 저항계수 체계별 신뢰도 분석)

  • Paik, In-Yeol;Sang, Hee-Jung
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • As a background study to apply the reliability-based resistance factors to the domestic concrete bridge design code, a comparative study is conducted for the design results and the reliability indexes obtained by adopting different resistance factor formats to yield the design strength of concrete structures. The design results which are calculated by applying the section resistance factors of the current domestic design code and the material resistance factors of Eurocode are compared for the concrete beam bridge. The reliability index is calculated by considering the uncertainties involved in material, dimension and strength equation during the design procedure to get the strength of concrete structure. Also, the sensitivity analysis is performed to figure out which design variables have great impact on the reliability index. The resistance factors of the current domestic bridge design code, AASHTO LRFD and Eurocode are applied to the bridge design for flexure and shear strength and the results show that the resistance factors of the domestic code give the largest reliability indexes. It is observed that the probabilistic distribution of the live load makes difference for the reliability index and the yield strength of reinforcing steel and the live load have great impact on the reliability of both flexural and shear strength of concrete beam through the sensitivity analysis.

A Review of Studies on Antibiotic Course and Antibiotic Resistance in Nasopharyngeal Pathogens in Primary Care Setting (일차진료 항생제 치료기간과 비인두 항생제 내성률에 대한 연구 고찰)

  • Shin, Hyang Hwa;Lee, Sun Haeng;Yun, Sung Joong;Chang, Gyu Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.32 no.2
    • /
    • pp.64-71
    • /
    • 2018
  • Objectives The purpose of this study is to examine the correlation of antibiotics administration duration and antimicrobial resistance by reviewing domestic and foreign literatures. Methods We searched literatures dated up to 23 February, 2018 in PubMed and Cochrane Library using terms of "Anti-Bacterial Agents", "Carrier State", "Nasopharynx", "Drug Administration Schedule", and also searched via RISS (Research Information Service System), KISS (Koreanstudies Information Service System), DBpia (DataBase Periodical Information Academic) using terms of antibiotics, resistance, and dose. Results In comparison with shortened and standard antibiotic course, longer treatment duration is associated with greater antimicrobial resistance or non-significant difference, but we cannot find literature that shortened antibiotic course increases antimicrobial resistance on human nasopharyngeal flora. Conclusions Currently, there is no evidence that completing the standard antibiotic course reduces antimicrobial resistance. It can be a strategy for reducing antibiotic use to apply Korean medicine treatment, as well as short-course antibiotic therapy or delayed antibiotic prescription. Additional well-designed trials should be conducted in domestic and foreign settings about the appropriate duration of antibiotic therapy.

Prediction on the Wear Resistance of Contact Tips for GMA Welding (GMA용접에서 콘택트팁의 내마모성에 대한 예측)

  • 김남훈;김희진;유회수;고진현
    • Journal of Welding and Joining
    • /
    • v.22 no.4
    • /
    • pp.35-42
    • /
    • 2004
  • Contact tips are required to have a higher resistance to wear and thus to have an extended life time under the advanced GMAW welding process. Several requirements have been specified and employed by domestic industries for selecting their tips for such a purpose. However no attempt has been made to justify their requirements based on the experimental data of wear resistance or life time of contact tips. In this study, five different contact tips with three different compositions were employed for actual GMA welding up to 4 hours and were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. It was further noticed that Cr is an excellent alloying element for improving the wear resistance of contact tips only when it is in an properly aged condition. Initial hardness may play some role in the early stage of wear but not in the later stage of welding because the microstructure of tip changes significantly by the prolonged exposure to welding arc heat. Based on these results, critical review has been made on the current requirements employed by domestic industries. Of importance is that a new guideline has been confirmed to be more reasonable.

Analysis of physical properties of high-performance concrete using domestic low-cost silica fume (국산 저가형 실리카퓸을 이용한 고성능 콘크리트의 물리적 특성 분석)

  • Kim, Sang Do;Yun, Kyung Ku;Ham, Seung Yeon;Lee, Kyeo Re
    • Journal of Industrial Technology
    • /
    • v.37 no.1
    • /
    • pp.32-36
    • /
    • 2017
  • In this study, as part of a research on the development of economical high-performance concrete with high strength and high quality, the physical properties of high-performance concrete were analyzed by substituting a certain amount of low-cost domestic silica fume exempted from the re-importation type distribution structure of the domestic production and the existing high-priced silica fume distribution structure. Performing tests to identify the physical properties of the fresh and hardened concrete and durability analogy of the concrete which use low-cost domestic silica fume and imported silica fume, the chloride ion penetration resistance test result showed that the strength difference between the low-cost silica fume and the imported silica fume is not big but the strength of the low-cost silica fume was measured higher than the imported silica fume. The chloride ion penetration resistance of all variables was measured as "very low". Since the low-cost domestic silica fume can be used as a high-performance admixture of concrete, the results suggest that it is possible to produce a more economical high-performance concrete.

An Experimental Study on the Properties of Durability of High Strength Concrete Using Domestic.Foreign Meta-kaolin (국내.외산 메타카올린을 사용한 고강도 콘크리트의 내구특성에 관한 실험적 연구)

  • Lee, Kang-Pil;Lee, Seung-Min;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.239-242
    • /
    • 2009
  • As the high-rise building increase due to the gravitation of population to big cities recently, it requires high quality and high performance of Concrete. As a result, people are keenly interested in Meta-kaolin as new admixture favorable from an economic perspective, which has strength and endurance with admixture at the same level like Silica-fume. Accordingly, as to Meta-kaolin, this study was to set by three levels like domestic one, foreign one, and Silica-fume, the water-binding material ratio 25%, and four level substitute like 0, 10, 20, and 30(%) in order to compare and analyze the quality durability of high-concrete according to the substitute of Meta-kaolin applicable with replacement of Silica-fume. As a result of performing experiment it was found that when water-binding material ratio increases, resistance of neutralization, carbonation, salt damage and sulfate decrease, and when replacement ratio of mineral admixture increases, depth of accelerating carbonation gets greater. Also, the combination of SF and MK-B favored resistance to chloride ion penetration better than MK-A, and it was found that when replacement ratio of binding material increases, the resistance to sulphuric acid increases. Therefore, based on this study, it was understood that meta-kaolin is useable in replacement of silicafume.

  • PDF

Comparison Osmotic Fragility of Erythrocyte Domestic Chicken, Duck, Quail, Dog, and Pig (가금과 보유가축 적혈구의 삼수적 취약성의 비교)

  • 민병만;김환균;김성열;구찬회
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.2
    • /
    • pp.144-149
    • /
    • 1992
  • The study was attempted to scrutinize the normal osmotic fragility of erythrocytes in domestic poultry such as chicken, quail and duck making a comparison with that in domestic mammalia such as dog and pig. Osmotic fragility of erythrocytes was determined on blood samples from 10 healthy adult animal in each species. Optical initial hemolysis of erytyrocytes occurred at $0.395{\pm}0.03%$ Nacl for chicken, $0.410{\pm}0.03%$ for duck, $0.440{\pm}0.02%$ for quail, $0.470{\pm}0.05%$ for dog and $0.560{\pm}0.03%$ for pig. Optical complete hemolysis of erytyrocytes occurred at $0.270{\pm}0.02%$ Nacl for chicken, $305{\pm0}.03%$ for duck, $0.360{\pm}0.02%$ for quail, $0.370{\pm}0.03%$ for dog and $0.455{\pm}0.03%$ for p. In other words, erythrocytes of poultry have stronger resistance to osmotic Iysis than that of mammalia, showing the strongest resistance In chicken among the tested poultry.

  • PDF