• 제목/요약/키워드: division of compressive strength results of concrete

검색결과 103건 처리시간 0.032초

PNS계 고성능 감수제와 시멘트 수용성 알칼리양과의 상용성이 콘크리트 물성에 미치는 영향 (Effects of compatibility between PNS Superplasticzer and soluble alkali of cements on performances of concrete)

  • 안태호;박준희;소광호
    • 한국결정성장학회지
    • /
    • 제27권4호
    • /
    • pp.173-177
    • /
    • 2017
  • PNS 감수제와 시멘트 페이스트의 유동성의 관계를 평가하기 위해 물시멘트비 35 %에 PNS의 감수제 첨가하여 세 가지 시멘트에 대해 평가하였다. 세 가지 시멘트의 화학적 성질은 XRD, XRF로 평가하고, 물시멘트비 33 %인 콘크리트에 대한 $Na_2SO_4$의 첨가 효과는 압축강도, 슬럼프, 공기 함량의 측정에 의해 평가하였다. 실험 결과는 시멘트 A 및 C에 황산나트륨 2.6 %를 첨가하면 슬럼프 손실이 개선됨을 보여 주었으며, 시멘트 E의 경우 황산나트륨 1.3 % 첨가가 효과적이었다.

A study on electrical and thermal properties of conductive concrete

  • Wu, Tehsien;Huang, Ran;Chi, Maochieh;Weng, Tsailung
    • Computers and Concrete
    • /
    • 제12권3호
    • /
    • pp.337-349
    • /
    • 2013
  • Traditional concrete is effectively an insulator in the dry state. However, conductive concrete can attain relatively high conductivity by adding a certain amount of electronically conductive components in the regular concrete matrix. The main purpose of this study is to investigate the electrical and thermal properties of conductive concrete with various graphite contents, specimen dimensions and applied voltages. For this purpose, six different mixtures (the control mixtures and five conductive mixtures with steel fibers of 2% by weight of coarse aggregate and graphite as fine aggregate replacement at the levels of 0%, 5%, 10%, 15% and 20% by weight) were prepared and concrete blocks with two types of dimensions were fabricated. Four test voltage levels, 48 V, 60 V, 110 V, and 220 V, were applied for the electrical and thermal tests. Test results show that the compressive strength of specimens decreases as the amount of graphite increases in concrete. The rising applied voltage decreases electrical resistivity and increases heat of concrete. Meanwhile, higher electrical current and temperature have been obtained in small size specimens than the comparable large size specimens. From the results, it can be concluded that the graphite contents, applied voltage levels, and the specimen dimensions play important roles in electrical and thermal properties of concrete. In addition, the superior electrical and thermal properties have been obtained in the mixture adding 2% steel fibers and 10% graphite.

화학적 침식을 받은 재래식 터널 콘크리트 라이닝의 내구성능 및 열화특성 (Characterization of Durability and Deterioration Eroded by Chemical Attack on the Concrete Lining in Conventional Tunnel)

  • 김동규;이승태;정호섭
    • 한국지반공학회논문집
    • /
    • 제23권12호
    • /
    • pp.25-32
    • /
    • 2007
  • 본 연구에서는 화학적 침식을 받는 환경에 놓인 터널 콘크리트 라이닝 구조물의 성능저하 원인을 분석하기 위하여 준공 후 70년 된 터널 구조물을 대상으로 외관조사, 비파괴검사, 코어시편의 압축강도, 탄산화, 투수성 평가 및 기기분석을 실시하였다. 그 결과 대상 터널 구조물은 수차례에 걸쳐 보수 및 보강공사의 흔적이 존재하였으며 내부 콘크리트 라이닝의 심한 균열, 누수 및 탈락현상 등으로 성능저하가 크게 발생한 상태였다. 콘크리트 라이닝의 비파괴 압축강도추정과 코어시편에 의한 압축강도는 위치마다 차이는 있었으나 각각 $17.5{\sim}34.7MPa$$12.8{\sim}40.3MPa$로 나타났으며, 반발경도법의 경우 콘크리트 표면이 누수 및 반응생성물의 영향으로 반발경도가 작게 나타나는 경우가 있었다. 콘크리트 라이닝 코어시편을 이용하여 전위차에 의한 촉진 염소이온 확산실험법으로 투수성 시험결과 일부 코어 시편을 제외한 대부분 낮은(Low) 영역으로 우수한 결과를 나타내었다. 또한 터널 콘크리트 라이닝 코어시편을 대상으로 미세구조를 분석한 결과 터널 콘크리트 라이닝 주변 지하공간으로부터 유입된 황산염이온의 영향으로 반응물질이 생성되어 성능이 저하되었으며, ettringite와 thaumasite 등의 생성에 의한 결정압에 의하여 균열 및 박리현상이 발생한 것으로 판단된다. 따라서 고내구성 콘크리트 라이닝의 제조를 위한 재료적 대책수립 및 관련지침안의 제정이 필요할 것으로 생각된다.

플라이애쉬와 고로슬래그 미분말의 혼합 사용한 무시멘트 알칼리 활성 모르터의 유동성 및 강도 특성 (Properties of the Flowability and Strength of Cementless Alkali-Activated Mortar Using the Mixed Fly Ash and Ground Granulated Blast-Furnace Slag)

  • 고경택;류금성;이장화
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.114-121
    • /
    • 2010
  • 포틀랜드 시멘트 제조 시 다량의 이산화탄소를 배출함으로써 많은 문제가 발생하고 있다. 그리고 화력발전소 및 제철소의 산업부산물인 플라이애쉬 및 고로슬래그 미분말은 시멘트와 일부 대체하여 콘크리트로 일부 재활용되고 있으나, 42% 정도를 해안 및 육상에 매립함으로써 환경적인 문제를 유발하고 있다. 최근 결합재로 시멘트를 사용하지 않은 알칼리 활성 콘크리트에 대한 연구가 활발히 진행되고 있다. 결합재로 플라이애시 또는 고로슬래그 미분말을 단독으로 사용한 연구는 많으나, 이들 결합재의 혼합사용에 대한 연구는 부족한 실정이다. 따라서 본 논문에서는 시멘트를 전혀 사용하지 않고 결합재로서 플라이애쉬와 고로슬래그 미분말을 혼합한 알칼리 활성 콘크리트를 개발할 목적으로 결합재의 혼합비율 및 양생온도가 알칼리 활성 모르터의 시공성, 압축강도 등 특성에 미치는 영향에 대해 검토하였다. 그 결과, 플라이애쉬와 고로슬래그 미분말의 혼합비는 시공성 및 강도에 큰 영향을 주지만, 양생온도는 비교적 큰 영향을 주지 않는 것으로 나타났다. 플라이애쉬와 고로슬래그 미분말을 50%씩 혼합하고, 9M NaOH과 쇼듐실리케이트를 1:1의 비율로 제조한 알칼리 활성화제를 사용할 경우에는 $20^{\circ}C$의 상온양생에서도 재령 28일에서 압축강도 65 MPa의 알칼리 활성 모르터를 제조할 수 있는 것으로 나타났다.

  • PDF

투수시트를 적용하여 잉여수를 탈수한 콘크리트의 강도 특성 (Characteristics of Excess Water Dewatered Concrete Using Permeable Liner)

  • 전규남;안기홍;이종석
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.675-682
    • /
    • 2013
  • 이 연구에서는 콘크리트 타설 시 발생하는 잉여수를 제거하여 피복 콘크리트의 성능을 향상 시키고자 거푸집에 구멍을 뚫지 않은 일반 유로폼에 투수시트를 부착하여 타설한 콘크리트의 물-결합재비 종류 및 시험체 높이에 따른 강도 특성을 분석하였다. 슈미트해머 반발경도 및 압축강도의 경우 투수시트면이 물-결합재비가 높은 배합일수록 크게 나타났으며, 시험체의 높이에 따라서는 상부보다는 중부 및 하부에서 크게 나타남을 알 수 있었다. SEM 분석 결과의 경우 수화물의 생성형태는 유사하였으나 투수시트면이 일반면에 비해 공극이 확연히 감소되고 밀실해 지는 것으로 나타났으며, MIP 분석 결과 투수시트를 사용하였을 경우 $0.01{\mu}m$ 이하 공극량이 최대 50%까지 감소되어 공극이 치밀해지는 것으로 나타났다.

Numerical simulation and analytical assessment of STCC columns filled with UHPC and UHPFRC

  • Nguyen, Chau V.;Le, An H.;Thai, Duc-Kien
    • Structural Engineering and Mechanics
    • /
    • 제70권1호
    • /
    • pp.13-31
    • /
    • 2019
  • A nonlinear finite element model (FEM) using ATENA-3D software to simulate the axially compressive behavior of circular steel tube confined concrete (CSTCC) columns infilled with ultra high performance concrete (UHPC) was presented in this paper. Some modifications to the material type "CC3DNonlinCementitious2User" of UHPC without and with the incorporation of steel fibers (UHPFRC) in compression and tension were adopted in FEM. The predictions of utimate strength and axial load versus axial strain curves obtained from FEM were in a good agreement with the test results of eighteen tested columns. Based on the results of FEM, the load distribution on the steel tube and the concrete core was derived for each modeled column. Furthermore, the effect of bonding between the steel tube and the concrete core was clarified by the change of friction coefficient in the material type "CC3DInterface" in FEM. The numerical results revealed that the increase in the friction coefficient leads to a greater contribution from the steel tube, a decrease in the ultimate load and an increase in the magnitude of the loss of load capacity. By comparing the results of FEM with experimental results, the appropriate friction coefficient between the steel tube and the concrete core was defined as 0.3 to 0.6. In addition to the numerical evaluation, eighteen analytical models for confined concrete in the literature were used to predict the peak confined strength to assess their suitability. To cope with CSTCC stub and intermediate columns, the equations for estimating the lateral confining stress and the equations for considering the slenderness in the selected models were proposed. It was found that all selected models except for EC2 (2004) gave a very good prediction. Among them, the model of Bing et al. (2001) was the best predictor.

노후 콘크리트 포장 파손에 대한 현장조사 및 실내시험 방법 (Methodology of Field Investigation and Laboratory Test for Distresses of Old Concrete Pavements)

  • 이기상;이준혁;강민수;조남현;정진훈
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.21-29
    • /
    • 2016
  • PURPOSES : The purpose of this study is to suggest a specific investigation guideline to decide priority of repairing old concrete pavements that pile up substantially. METHODS : In this study, a principle of division of homogeneous sections was proposed to reflect the characteristics of the pavement reasonably in the specific investigation results. In addition, a checklist and guideline of field investigation were suggested for the old concrete pavement sections, which require inspection toward their durability and structural performance. Furthermore, the items of laboratory test necessary to the old concrete pavement were suggested based on the existing laboratory test considering characteristics of the old concrete pavement. The present condition of the old concrete pavement could be analyzed by the test results. RESULTS : A method of division of homogeneous sections suitable for the specific investigation of the old concrete pavement was suggested. The proportions of distress severity of pavement sections were compared by distress type to figure out the present state of the old concrete pavement. Scaling, durability cracking (or alkali-silica reaction), and longitudinal spalling were selected as the most severe distress types. The detailed positions of the sections were also suggested. The checklist of the specific investigation was categorized by field survey and laboratory test, and its evaluation criteria were proposed. The three types of the sections of durability cracking (or alkali-silica reaction), bridge connection, and asphalt overlay were selected as the sections of the field survey. The compressive strength, void structure, and chloride penetration depth were suggested as the items of the laboratory test. CONCLUSIONS : A fundamental level of the guideline was suggested in this study to resolve the problem of old concrete pavement. Appropriate guidelines related to the repair of the old concrete pavement should be provided by performing additional research efforts.

고로슬래그 미분말을 다량 치환한 콘크리트의 초기품질에 미치는 온도의존성 (Temperature Dependency Affecting the Properties at Early Age of the Concrete Containing High Volume Blast Furnace Slag)

  • 한천구;이장화;고경택;한민철;이주선
    • 한국건설순환자원학회논문집
    • /
    • 제4권1호
    • /
    • pp.74-80
    • /
    • 2009
  • 본 연구는 BS를 다량 치환한 콘크리트의 양생온도에 따른 초기품질특성을 검토하여, 온도의존성을 분석한 것으로, 그 결과를 요약하면 다음과 같다. 먼저, 굳지않은 콘크리트의 특성으로 BS 치환율이 증가할수록 유동성은 증가하고, 공기량은 미세하게 감소하는 것으로 나타났다. 응결시간은 전반적으로 BS 치환율이 증가할수록 양생온도가 낮을수록 지연되는 것으로 나타났는데, 단, 양생온도 $35^{\circ}C$의 경우 BS 치환율 80%의 경우라도 $5^{\circ}C$, $20^{\circ}C$의 Plain에 비해 응결시간이 크게 촉진되는 것으로 나타나, 온도의존성이 매우 큰 것을 알 수 있었다. 경화 콘크리트의 특성으로 압축강도는 전반적으로 BS 치환율이 증가하고 양생온도가 낮아질수록 초기 압축강도는 비례적으로 저하하였는데, 양생온도가 높을수록 BS 치환율 증가에 따른 강도 저하폭이 상당부분 감소하여, 역시 온도의존성이 매우 중요함을 알 수 있었다.

  • PDF

순환골재 혼합비율에 따른 인터로킹 블록의 물리적 특성에 관한 연구 (A Study on the Physical Properties of Interlocking Block with the Contents of the Recycled Aggregate)

  • 전찬수;송태협;윤상혁
    • 한국건설순환자원학회논문집
    • /
    • 제7권4호
    • /
    • pp.71-78
    • /
    • 2012
  • 순환골재는 건설폐기물을 재활용함으로써 자원절약 및 대체자원의 개발과 환경보호의 측면에서 국가 사회적으로 많은 이점을 가지고 있다. 하지만 낮은 밀도와 높은 흡수율을 가지는 저품질 순환골재는 구조용 콘크리트 골재로 사용되지 못하고 주로 저부가가치로 사용되고 있다. 따라서, 이를 위하여 폐콘크리트 파 분쇄 후 발생되는 순환골재의 재료적 특성을 규명하기 위하여 물리적인 주요성질인 시멘트함유량, 절대건조밀도, 흡수율, 등을 검토하고, 2차 제품 생산을 위한 배합설계(안)을 도출하여 이를 적용한 배합으로 생산된 시제품의 휨 강도, 흡수율, 동결 융해 후 휨 강도, 압축강도, 기건비중 등에 대한 성능평가를 실시하여 품질기준 GR규격과 비교 검토 하였다. 실헌결과 순환골재 대체율 50~90%로 증가함에 따라 GR F 4007의 성능기준 보다 우수한 품질로 나타났으며, 순환골재를 사용한 콘크리트 2차 제품의 제조 및 활용할 수 있는 소정의 물리적 특성을 확보함에 따라 각종 건설공사에서 다양하게 사용이 가능 할 것으로 판단된다.

  • PDF

초고성능 콘크리트의 수화발열 및 역학적 특성 모델 (Models for Hydration Heat Development and Mechanical Properties of Ultra High Performance Concrete)

  • 차수원;김기현;김성욱;박정준;배성근
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.389-397
    • /
    • 2010
  • 콘크리트는 역학적 성능, 내구성능, 경제성이 우수한 재료이지만 장경간 교량에 적용하기는 쉽지 않은데, 이는 콘크리트의 중량 대비 강도가 낮기 때문이다. 초고성능 콘크리트는 높은 압축강도를 가지며 굵은 골재를 사용하지 않으므로 단면의 크기를 줄일 수 있어, 장경간 교량 바닥판으로 활용이 기대된다. 그러나 초고성능 콘크리트는 재료 특성상 단위결합재량이 많으므로 바닥판 양생과정에서 수화열에 의한 균열이 발생할 수 있다. 이 연구에서는 UHPC 바닥판의 초기재령 균열 위험성을 평가하기 위한 기초 작업을 수행하였다. 먼저 단열온도 상승시험 결과를 바탕으로 2변수 모델과 S자형 함수의 중첩으로 단열온도 상승곡선을 모델링하고, 등가재령의 개념을 도입하여 UHPC의 아레니우스 상수를 결정하였다. 이상의 결과를 실물크기 시험체에 대한 수화발열 측정시험으로 검증하였다. 다음으로 초음파 속도 측정 결과와 하중 재하에 의하여 탄성계수, 인장강도, 압축강도와 같은 UHPC의 역학적 특성을 구하였다.