• Title/Summary/Keyword: division of compressive strength results of concrete

Search Result 103, Processing Time 0.028 seconds

Fundamental Properties and Hydration Characteristics of Mortar Based on MgO Added Industrial By-products (산업부산물을 첨가한 MgO 기반 모르타르의 기초물성 및 수화특성에 관한 연구)

  • Hong, Sung-Gul;Kim, Do-Young;Lee, Dong-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.565-572
    • /
    • 2013
  • Hydration and physical characteristics of chemically-bonded phosphate ceramic (CBPC) binder based on dead-burned Mg-O with six different blends are investigated for efficient repair construction material by retarding set phase with $H_3BO_3$. The test specimen of the blender with silica fume shows higher compressive strength after 75 days. The CBPC with silica fume results in higher modulus of rupture that others. The test specimens of CBPC eludes lower calcium ion than that of OPC (Ordinay Portland Cement). The X-ray diffraction pattern shows that hydration results in the formation of magnesium hydroxide, M-S-H gel and $MgCO_3$ for the specimen with silica fumes. Combination with calcium for MgO is not desirable due to no formation of chemical bond between two components. Based on the experimental program, the mixture of MgO and silica fume shows efficient performance in strength and durability.

Optimum Mix Proportions of High Fluidity Antiwashout Underwater Concrete Using Ground Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 고유동 수중불분리성 콘크리트의 최적배합비 도출)

  • Kim, Sung-Wook;Park, Jung-Jun;Bae, Su-Ho;Park, Jae-Im
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3704-3712
    • /
    • 2012
  • Recently, antiwashout underwater concrete has been increasingly used for marine foundations of long span bridges. However, to shorten the construction period of antiwashout underwater concrete used in marine foundations, high fluidity antiwashout underwater concrete should be manufactured largely improving fluidity than the previous one. Thus, the objective of this experimental research is to suggest optimum mix proportions of high fluidity antiwashout underwater concrete. For this purpose, concrete specimens containing ground granulated blast furnace slag were manufactured according to the dosage of antiwashout admixture for unit binder contents of 550 and 600kg/$m^3$, respectively. And then, their quality performances such as slump flow, setting time, underwater segregation resistance, and ratio of compressive strength were evaluated according to the related specification of Korea Concrete Institute. It was observed from the test results that the minimum dosage of antiwashout admixture was necessary to satisfy the related specification.

Study on the Stability Evaluation of Concrete Erosion Control Dam by using Non-destructive Test for Compressive Strength (콘크리트 비파괴시험법을 이용한 사방댐 안정도 평가에 관한 연구)

  • Park, Ki-Hyung;Kim, Min-Sik;Joh, Sung-Ho;Lee, Chang-Woo;Youn, Ho-Joong;Kim, Kyong-Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.1
    • /
    • pp.90-96
    • /
    • 2013
  • This study was conducted to investigate a stability trend within 6 above average and 4 blow average erosion control dams, which were selected by The Korean Association of Soil and Water Conservation and were built in 1990s in Gyeonggi and Gangwon Province. The study was aimed to measure rebound hardness of upstream face, flood way and downstream face from those dams selected by using 'Concrete Test Hammer'. The main purposes of the study are selection of compression strength prediction equation and scope of wavelength, which successfully demonstrate non-destructive test results for erosion control dams. There is an opportunity to increase disaster prevention ability when stability vulnerability of concrete erosion control dam is detected in a timely manner. Results of the compression strength investigation express that there is a consistency with visual inspection of stability that has been processed by The Korean Association of Soil and Water Conservation. We concluded that a prediction equation, which was developed by Architectural Institute of Japan (AIJ), shows highest suitability in Korean erosion control dams when stability investigation is performed. The detailed criteria for the test result are 'stable', 'detail inspection required' and 'poor' for over 300 $kgf/cm^2$, 250~300 $kgf/cm^2$ and below 250 $kgf/cm^2$ respectively. Standards for stability of Korean erosion control dam and a compression strength prediction equation (that corresponds to the standards of the stability) should be established on the basis of chronological data of erosion control dam compression strength. Systematical approach for stability inspection that carries out remodeling or repair when problem on erosion control structures are detected through visual inspection and simple stability test, is necessary for the future disaster prevention.

Structural Performance Evaluation of Offshore Modular Pier Connection using Ultra-high Performance Concrete (초고성능 콘크리트를 활용한 해상 모듈러 잔교 연결부의 구조성능 평가)

  • Lee, Dong-Ha;Kim, Kyong-Chul;Kang, Jae-Yoon;Ryu, Gum-Sung;Koh, Kyung-Taek
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.351-357
    • /
    • 2022
  • In this study, offshore modular pier system using the ultra-high performance concrete was developed for the offshore construction environment. For the application of offshore modular pier system, the design, fabrication, and construction performance evaluation were performed using ultra-high performance concrete a compressive strength 120 MPa or more and a direct tensile strength 7 MPa or more. For offshore piers previously constructed with precast concrete, it was intended to verify the idea and possibility of solving errors due to position or vertical deformation during the driving of the foundation pile part during the construction stage. Furthermore, a offshore modular pier system was fabricated with ultra-high performance concrete for the construction performance evaluation. The results showed that a offshore modular pier system secured about 9 % of sectional performance of load bearing capacity under ultimate load conditions. If the offshore modular pier system developed through this study is utilized in the future, it is judged that competitiveness due to sufficient durability and constructability can be secured.

Performance evaluation of SFRC for tunnel segments based on large beam test (대형보 실험을 통한 TBM 터널 세그먼트용 강섬유보강콘크리트 성능평가)

  • Moon, Do-Young;Roh, Hwasung;Chang, Soo-Ho;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.287-298
    • /
    • 2014
  • In order to develop SFRC TBM tunnel segment, evaluating the SFRC mixture was conducted through flexural tests of SFRC beams without ordinary steel reinforcement in this study. Considered variables were compressive strengths of SFRC, aspect and mix ratio of steel fibers and total 16 specimens were fabricated and tested until failure. The load-vertical displacement results demonstrates that the effect of aspect ratio is minor when compared to results form small beam test(Moon et al, 2013). A SFRC beam resists the vertical load until the width of crack reaches to 7 mm due to steel fibers across cracked surfaces. Moreover, it is found that flexural moment estimated by equation of TR No. 63(Concrete Society, 2011) is useful for prediction of nominal strength for SFRC structure. From the investigation of fiber distribution in cracked section, it is found that dispersion improved in actual size beam compared to in standard small beam for evaluation of flexural strength.

Study on Direct Tensile Properties and Reliability Review of Steel Fiber Reinforced UHPC (강섬유 보강 UHPC의 직접인장 특성 및 신뢰성 검토에 관한 연구)

  • Park, Ji Woong;Lee, Gun Cheol;Koh, Kyung Taek;Ryu, Gum Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.125-132
    • /
    • 2018
  • In this study, a direct tensile test was planned to identify the tensile performance of UHPC, and the irregularity of cracks, which is a problem of the direct tensile test, was complemented through the introduction of notches at the center of a specimen. In this regard, a number of specimens divided by batch to reduce the deviation of direct tensile test values were fabricated to present reference data with respect to highly reliable direct tensile strength values. In addition, the mechanical properties and reliability of the specimens were examined under the curing conditions of the specified design strength of 120MPa for the steel fiber reinforced concrete with 1.5% fiber volume fraction, which is most suitable for the field application. As a result, the deviation of averages by batch between compressive strength and direct tensile strength did not show a large difference, and all cracks occurred within 20mm in the direct tensile test. At the 95% confidence interval of the direct tensile strength, the range was considerably small in the mean and the standard deviation, and there was no significant difference depending on the curing conditions. The results confirmed that a stable direct tensile test was performed, and highly reliable results were obtained through the fabrication of specimens by batch and test progress.

A Fundamental Study for Proper Maximum Size of Coarse Aggregate of Ready-mixed Shotcrete (레디믹스트 숏크리트의 적정 골재최대치수 제안을 위한 기초적 연구)

  • Ma, Sang-Joon;Choi, Hee-Sup;Kim, Dong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 2008
  • This study was carried out to investigate and analyse the influence of maximum size of coarse aggregate and quality control of aggregate on the properties of shotcrete through the laboratory and field test. From the results of the test, as the maximum size of coarse aggregate decreased from 13 mm to 8 mm, plasticity property declined and compressive strength and dynamic modulus of elasticity of hardened concrete increased remarkably, so it was found that the aggregate size 8 mm was superior to 13, 10 mm in fluidity, constructability and durability. Therefore, it was advisable for well maximum size of coarse aggregate to apply to the 8mm aggregates through the Ready-mixed Method for quality control and minimum segregation.

Long-Term Durability Estimation of Cementless Concrete Based on Alkali Activated Slag (알칼리 활성 슬래그 기반 무시멘트 콘크리트의 장기 내구성 평가)

  • Lee, Hyun-Jin;Lee, Seok-Jin;Bae, Su-Ho;Kwon, Soon-Oh;Lee, Kwang-Myong;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • It has been well known that concrete structures exposed to chloride and sulfate attack environments lead to significant deterioration in their durability due to chloride ion and sulfate ion attack. The purpose of this experimental research is to evaluate the long-term durability against chloride ion and sulfate attack of the alkali activated cementless concrete replacing the cement with ground granulated blast furnace slag. For this purpose, the cementless concrete specimens were made for water-binder ratios of 40%, 45%, and 50%, respectively and then this specimens were cured in the water of $20{\pm}3^{\circ}C$ and immersed in fresh water, 10% sodium sulfate solution for 28, 91, 182, and 365 days, respectively. To evaluate the long-term durability to chloride ion and sulfate attack for the cementless concrete specimens, the diffusion coefficient for chloride ion and compressive strength ratio, mass change ratio, and length change ratio were measured according to the NT BUILD 492 and JSTM C 7401, respectively. It was observed from the test results that the resistance against chloride ion and sulfate attack of the cemetntless concrete were comparatively largely increased than those of OPC concrete irrespective of water-binder ratio.

Fracture Toughness of a Center Notched Concrete Disk (중앙에 노치가 있는 콘크리트 디스크의 파괴인성)

  • Park Hyun-Jae;Jang Hee-Suk;Lee Seung-Hoon;Jin Chi-Sub
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.851-858
    • /
    • 2004
  • Purpose of this paper is to determine the appropriate size of a center notched disk specimen for mode I fracture toughness $K_{IC}$. For this purpose, mode I test results with various sizes of center notched disk were compared with the RILEM three-point-bend test ones. Compressive strength of concrete used in this paper was 44.9 MPa. Diameters of 200, 300, 400 mm, thickness of 75, 100, 125 mm, and notch length ratios an of 0.3, 0.4, 0.5, 0.6 were used for the mode I disk test. Also, diameter of 300mm thickness of 100mm, and notch length ratios a/R of 0.3, 0.4, 0.5, 0.6 were used for the mixed mode disk test. Mixed mode stress intensity factors were investigated by changing notch angles for the disk specimen. Stress intensity factors of a center notched disk were calculated with the various methods for comparison. From the test results, mode I fracture toughness calculated from the disk specimen with diameter of 300 mm, thickness of Inn and notch length ratio a/R of 0.5 was very similar to the RILEM three-point-bend test ones. And it is verified that stress intensity factors for mixed mode can be easily calculated with the disk specimen.

Internal Confining Stress of Internally Confined Hollow Columns under Compressive Load (압축을 받는 내부 구속 중공 RC 기둥의 내부 구속력)

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.243-254
    • /
    • 2013
  • Internally Confined Hollow RC(ICH RC) column consisted of concrete, transverse reinforcement, longitudinal reinforcement, and inner tube. It had good strength and ductility by core concrete was become triaxial confining state with transverse reinforcement and inner tube. There were two confining stress as external confining stress and internal confining stress in an ICH RC column. While external confining stress was researched by former researchers, internal confining stress has not researched. In this paper, confining stress of both Hollow RC column and ICH RC column was investigated using FEA program. Relation between theoretical confining stress and internal confining stress was drawn by analysis results. Modified failure condition equations of inner tube were suggested to base on failure condition equations of inner tube by former researcher. When thickness of inner tube was calculated by modified equations, it could be economic because thickness of inner tube was reduced 50% compared with former researcher equations in order to same confining stress.