• Title/Summary/Keyword: divinylbenzene (DVB)

Search Result 75, Processing Time 0.028 seconds

Suspension Polymerization with Hydrophobic Silica as a Stabilizer II. Preparation of Polystyrene Composite Particles Containing Carbon Black (소수성 실리카를 안정제로 하는 현탁중합 II. 카본블랙을 함유하는 폴리스티렌 복합체 입자의 합성)

  • Park, Moon-Soo
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.505-511
    • /
    • 2006
  • We tried to prepare polystyrene composite particles containing carbon black by suspension polymerization with water as a reaction medium. Hydrophobic silica was selected as a stabilizer and oil-soluble azobisisobutyronitrile (AIBN), as an initiator. All polymerization reactions were carried out at a fixed temperature of $75^{\circ}C$. Stabilizer concentration was varied from $0.17{\sim}3.33wt%$ compared to water, where particles with $7.96{\mu}m$ in average diameter were obtained at 1.57 wt% of stabilizer. Increase in divinylbenzene concentration, as a crosslinking agent, from $0.1{\sim}1.0 wt%$ compared to monomer exhibited a large increase in average particle diameter Incorporation of 1wt% of carbon black compared to monomer produced an increase in average diameter It is speculated that viscosity lower than that necessary to induce even dispersion of carbon black particles led to poor dispersion, and as a result, large particles. For a styrene mixture containing 3 wt% carton black compared to monomer, enhanced dispersion due to an increase in carbon black concentration reduced average particle diameters. For styrene mixtures containing 1 and 3 wt% carbon black compared to monomer, preparticles before polymerization and polymer composite particles after polymerization showed a similar tendency towards particle formation. When carbon black concentration compared to monomer was increased to 5 and 7 wt%, styrene mixtures exhibited a large increase in viscosity and thus better dispersion of carbon black particles, which led to a decrease in preparticle diameters. However, these particles experienced agglomeration in the polymerization process, and polystyrene composite particles increased in average diameter.

Adsorption of an uranyl ion onto a divinylbenzene amidoxime resin in sodium carbonate solutions (탄산염 용액에서 아미드옥심 수지에 대한 우리닐 이온의 흡착거동)

  • Joe, Kihsoo;Lee, Eil-Hee;Kim, Kwang-Wook;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.326-331
    • /
    • 2008
  • Distribution coefficients (Kd) of uranyl ion onto divinylbenzene amidoxime resins were measured in sodium carbonate solution and the Kd values were increased up to about 70 as the resin bead size was decreased. At a condition of 0.0044 M $Na_2CO_3$, the adsorption capacity for uranium was $3.4{\mu}mole$ U/g-resin. The Kd values in the 0.5 M $Na_2CO_3-NaHCO_3$ solution, ranging from pH 9 to pH 11, revealed that they were increased as the pH increased and revealed lower values than those in the pure sodium carbonate solution. The amidoxime resins were characterized by FTIR-ATR showing the absorption bands of the amidoxime functional groups. A species of the uranyltricarbonate complex, $UO_2(CO_3)_3^{-4}$, was confirmed by UV-Vis spectroscopy, revealing four absorption peaks between 400 and 500 nm. Uranium was separated from some fission products by a column operation. However, most of the uranium and fission products were eluted before an adsorption and only a small amount of uranium was adsorbed onto the resin due to the low capacity of the resin.

Studies on the Separation of Uranium from Seawater by Composite Fiber Adsorbents(2)(Characterization of Adsorption-Desorption) (복합재료 섬유흡착제를 이용한 해수로부터 우라늄 분리에 관한 연구(2)(흡-탈착 특성))

  • Hwang, Taek-Seong;Park, Jeong-Gi;Hong, Seong-Gwon;Sin, Hyeon-Taek;No, Yeong-Chang
    • Korean Journal of Materials Research
    • /
    • v.6 no.8
    • /
    • pp.761-767
    • /
    • 1996
  • The composite fiber adsorbents containing amidoxime group were prepared and separation properties of uranium ion from seawater were investigated. The amount of uranium adsorption was increased with an increase in adsorption time. When the mole ratio of monomer and comonomer, such as acrylonitrile (AN), tetraethyleneglycol dimethacrylate(TEGMA), and divinylbenzene (DVB), were 1 :0. 1 :0.003, this resin showed the maximum adsorption ability for uranium at a level of pH 8. The amount of uranium adsorption was also increased linearly to one hour with an increase in the content of adsorbent which was added in the composite fiber adsorbents(CFA). The maximum adsorption for uranium of CF A showed at $25^{\circ}C$. Hence, the adsorption ability of CF A for calcium and magnecium ions were increased gradually by the recycling of adsorption and disorption, the adsorption content of their on were 0.3, 0.9mmole/g-adsorbents, respectly. It also showed that the adsorption contents of Ca and \1g ions were much lower than them of uranium. The desorption of uranium on the CF A was carried out , bout 100% within 30min, and the desorption rate of various CF A were equalled.

  • PDF

A New Sampling and SEC Method for Analysis of Underivatized Cellulose (셀룰로스의 분석을 위한 새로운 시료처리 및 크기배제크로마토그래피)

  • Lee, Seung Ho;Park, Hee Young
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.2
    • /
    • pp.190-196
    • /
    • 1998
  • A new sampling and size exclusion chromatography (SEC) method for the analysis of underivatized cellulose are established. In this method, cellulose materials are first dissolved in N-methylmorpholine N-oxide (NMMO) and diluted by adding dimethyl sulfoxide (DMSO) to make the sample solutions of about 0.1% in 50/50 NMMO/DMSO (w/w). Sample solutions are analyzed using a glucose-treated divinylbenzene (DVB) SEC column and DMSO containing 0.05M LiBr and 2.5 blank as the eluant. The flow rate was constant at 1 mL/min and the whole SEC system including the column was heated at $80^{\circ}C$ to reduce the viscosity of DMSO. Addition of 0.05 M LiBr eliminated SEC baseline drifting, and addition of 2.5 blank seems to reduce the interaction between the sample and the column packing. SEC molecular weights were determined using a calibration curve constructed from a series of narrow pullulan standards, and they were used to measure the degree of degradation during two different pulp-to-sponge processings.

  • PDF

A Study on the U(VI), Ca(II) and Lu(III) Metal Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Ca(II) 및 Lu(III) 금속 이온들에 관한 연구)

  • 정만태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The new ion exchange resin was synthesized from chloromethylated styrene-1,4-divinylbenzene(DVB) with 1-aza-15-crown-5 macrocyclic ligand by substitution reaction. The effect of pH, time, dielectric constant of solvent and cross-linked of the matrix on the adsorption for $UO_2^{2+}$, $Ca^{2}$ and $Lu^{3+}$ was investigated. The metal ion was not adsorbed on the resins below pH 3 but above pH 4 fast adsorption behavior was showed. The optimum equilibrium time for adsorption of metallic ions was two hours. The adsorption selectivity determined in ethanol matrix was in increasing order $UO_2^{2+}>Ca^{2}>Lu^{3+}$. The adsorption power was in the order of 1%, 2%, 10% and 20% -crosslinked resin, but adsorption properties of resins decreased in proportion to the order of dielectric constant of solvents used. In addition, these metal ions could be separated in the column packed with 1% crosslinked resin by pH2.5 $HNO_3$ as an eluent.

  • PDF

Investigation of Adsorption Mechanism and Selective Adsorption of Carbonyl Compounds of Mainstream Tobacco Smoke by Ion Exchangers (이온교환체에 의한 담배 주류연 중 카보닐 화합물의 선택적 흡착 특성 및 흡착 메카니즘 구명)

  • Lee John-Tae;Kim Hyo-Keun;Ji Sang-Un;Hwang Keon-Joong;Rhee Moon-Soo;Park Jin-Won
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.26 no.2 s.52
    • /
    • pp.159-167
    • /
    • 2004
  • This work has been conducted to select appropriate filter materials for removing carbonyl compounds in mainstream tobacco smoke. To investigate of the usability of this filter materials, two types of bead ion exchangers were synthesized and their adsorption characteristics for carbonyl compounds were investigated. Sulfonic acid group-containing cation exchanger and ammonium group-containing anion exchanger were synthesized by the suspension polymerization of glycidylmethacrylate(GMA) and divinylbenzene(DVB) followed by the subsequent functionalization, respectively. The removal efficiency of carbonyl compounds by these two ion exchangers increased in the presence of moisture. However, the amount of carbonyl compounds adsorbed on the anion exchanger was larger than that on the cation exchanger under two levels of water contents tested. This phenomenon seems to arise from the electron delocalization in carbonyl group of the anion exchangers. There was not any significant relationship between the amount of carbonyl compounds adsorbed on ion exchangers and the length of adsorption column. From the large ion exchange capacity and rapid ion exchange reaction rate of the anion exchanger, it is suggested that the anion exchanger may be a good filter material for removing carbonyl compounds in the mainstream tobacco smoke.

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

Fabrication and Characteristics of Partially Covalent-crosslinked Poly(arylene ether sulfone)s for Use in a Fuel Cell (고분자 전해질 연료전지용 부분 공유 가교된 술폰화 폴리아릴렌에테르술폰 막의 제조 및 특성)

  • Byun, Hong-Sik;Yoon, Kyung-Seok;Choi, Jong-Ho;Choi, Jun-Kyu;Hong, Sung-kwon;Hong, Young-Taik
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.274-281
    • /
    • 2008
  • Covalent-crosslinked sulfonated poly(arylene ether sulfone) (SPAES) copolymers were synthesized copolymerization technique and additionally crosslinked with divinylbenzene (DVB). To optimize the reaction condition, a concentration of crosslinking agent and a reaction time were varied in the ranges of $30{\sim}90\;v/v%$ and $30{\sim}720\;min$. The properties of the crosslinked membranes were investigated by SEM, TGA and the measurement of proton conductivity. It was found that the proton conductivity of crosslinked membranes decreased depending on a degree of crosslinking while water uptake and methanol permeability reduced.

Novel Solid Phase Extraction Procedure for Some Trace Elements in Various Samples Prior to Their Determinations by FAAS

  • Sacmaci, Srife;Kartal, Senol;Sacmaci, Mustafa;Soykan, Cengiz
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.444-450
    • /
    • 2011
  • A novel method that utilizes poly(5-methyl-2-thiozyl methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid-co-divinylbenzene) [MTMAAm/AMPS/DVB] as a solid-phase extractant was developed for simultaneous preconcentration of trace Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), and Zn(II) prior to the measurement by flame atomic absorpiton spectrometry (FAAS). Experimental conditions for effective adsorption of the metal ions were optimized using column procedures. The optimum pH value for the simultaneously separation of the metal ions on the new adsorbent was 2.5. Effects of concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of the analytes were investigated. A high preconcentration factor, 100, and low relative standard deviation values, $\leq$1.5% (n = 10), were obtained. The detection limits (${\mu}gL^{-1}$) based on the 3s criterion were 0.18 for Cd(II), 0.11 for Co(II), 0.07 for Cr(III), 0.12 for Cu(II), 0.18 for Fe(III), 0.67 for Mn(II), 0.13 for Ni(II), 0.06 for Pb(II), and 0.09 for Zn(II). The validation of the procedure was performed by the analysis of two certified reference materials. The presented method was applied to the determination of the analytes in various environmental samples with satisfactory results.