• Title/Summary/Keyword: divided electrodes

Search Result 66, Processing Time 0.029 seconds

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

Elemental alteration of the surface of dental casting alloys induced by electro discharge machining (치과용 주조 합금의 방전가공에 따른 표면 성분 변화)

  • Jang, Yong-Chul;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

EFFECTS OF EUGENOL, CAPSAICIN AND DEMETHOXY-NE ON THE PAIN RESPONSE OF DENTAL PULP (Eugenol, Capsaicin과 Demethoxy - NE가 치수동통 반응에 미치는 영향)

  • Lee, Eun-Goo;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.10-21
    • /
    • 1992
  • The purpose of this study was to investigate the analgesic effect of eugenol, capsaicin and demethoxy-NE. Young adult cats, weighing 2.0 to 3.0kg, were used. Each animal was anesthetized (${\alpha}$-chloralose 60mg per kg body weight) and divided into four groups; control, eugenol, capsaicin and demethoxy-NE group. The anterior digastric muscles were exposed and a pair of electrodes was inserted to record the electromyograms. To expose the pulp, each canine teeth was prepared with a low speed bur under cooling and used for recording anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp. To observe effects on jaw opening reflex, inferior alveolar nerve of both sides were exposed for drug application and wire electrodes were inserted in anterior digstric muscle for recording the EMGs. To observe effects on action potential, saphenous nerves of both sides were exposed and three tissue pools were made from surrounding tissue. The most distal pool was used for applying stimulation, the most proximal one for recording of action potential, and the other one for drug application. One side of inferior alveolar nerve and saphenous nerve were used for eugenol, capsaicin, or demethoxy-NE application, the other side of nerve for control experiments(only vehicle application). Anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp were recorded before drug application, immediate after drug application, at 60 and 120 minutes, and 5 days after drug application. Action potentials were recorded before drug application, immediate after 30 minutes drug application, at 30, 60 and 120 minutes after drug had been washed out. The results were as follows; 1. Eugenol had a continuous blocking effect on the anterior digastric muscular EMGs evoked by noxious pulp stimulation and after 5 days, showed completely blocking effect. 2. After 5 days, demethoxy-NE applied to dental pulp had a considerable blocking effect on the jaw opening retlex evoked by noxious stimulation but capsaicin had no significant effect. 3. After 5 days, eugenol group showed the strongest blocking effect among the all experimental groups on the jaw opening reflex evoked by noxious stimulation of dental pulp and capsaicin group showed the weakest blocking effect. 4. Eugenol had a completely blocking effect on the action potential conductivity of peripheral nerve. Capsaicin and demethoxy-NE had the blocking effect on the action potential conductivity of ${\alpha}$-and C-nerve fibers. 5. Capsaicin, demethoxy-NE and eugenol applied to inferior alveolar nerve surppressed the jaw opening reflex evoked by noxious stimulation of dental pulp.

  • PDF

Brain Wave Characteristic Analysis by Multi-stimuli with EEG Channel Grouping based on Binary Harmony Search (Binary Harmony Search 기반의 EEG 채널 그룹화를 이용한 다중 자극에 반응하는 뇌파 신호의 특성 연구)

  • Lee, Tae-Ju;Park, Seung-Min;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.8
    • /
    • pp.725-730
    • /
    • 2013
  • This paper proposed a novel method for an analysis feature of an Electroencephalogram (EEG) at all channels simultaneously. In a BCI (Brain-Computer Interface) system, EEGs are used to control a machine or computer. The EEG signals were weak to noise and had low spatial resolution because they were acquired by a non-invasive method involving, attaching electrodes along with scalp. This made it difficult to analyze the whole channel of EEG signals. And the previous method could not analyze multiple stimuli, the result being that the BCI system could not react to multiple orders. The method proposed in this paper made it possible analyze multiple-stimuli by grouping the channels. We searched the groups making the largest correlation coefficient summation of every member of the group with a BHS (Binary Harmony Search) algorithm. Then we assumed the EEG signal could be written in linear summation of groups using concentration parameters. In order to verify this assumption, we performed a simulation of three subjects, 60 times per person. From the simulation, we could obtain the groups of EEG signals. We also established the types of stimulus from the concentration coefficient. Consequently, we concluded that the signal could be divided into several groups. Furthermore, we could analyze the EEG in a new way with concentration coefficients from the EEG channel grouping.

Cerebral Blood Flow Velocity Measurement by TCD: The Effects of Interferential Current (TCD를 이용한 뇌혈류속도 측정: 간섭전류의 효과)

  • Lee Mun-Hwan;Han Jong-Man
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.126-147
    • /
    • 2005
  • TCD(transcranial doppler, TCD) units is a equipment that measure a blood flow velocity in the middle cerebral artery(MCA), anterior cerebral artery(ACA), posterior cerebral artery(PCA), and vertebral artery(VA). The aim of this study was to determine the influence on cerebral blood flow velocity according to different stimulation frequency of interferential currents. 50 patients who has a cervical pain were participated in this study and randomly divided into one of the three experimental, placebo, and control group: (1)IFS 1; $10{\sim}30Hz$ was applied, (2)IFS 2; $30{\sim}50Hz$ was applied, (3)IFS 3; $50{\sim}100Hz$ was applied, (4)placebo; suction only applied, and (5)control; neither suction nor interferential stimulation applied. In the IFS groups, interferential stimulations were applied through four suction electrodes application from the 5th cervical to the 1st thoracic level. The results were as follow; 1. MCA was statistically significant with IFS 1, IFS 2, IFS 3, and Placebo group(p<0.05), But there was no statistical significance between IFS 1 and IFS 3 group(p>0.05). 2. ACA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on ACA(p<0.05). 3. PCA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on PCA(p<0.05). 4. VA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on VA(p<0.05).

  • PDF

The Effect of Electrical Stimulation Level on Autonomic Nerve System in Normal Adults (전기자극 수준이 정상 성인의 자율신경계에 미치는 영향)

  • Jin, Hee-Kyung;Cho, Sung-Hyoun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2029-2037
    • /
    • 2015
  • The purpose of this study was to investigate the effect the interferential current (IFC) stimulation level according to autonomic nerve system (ANS) of healthy adults. IFC measured with adhesive 2-pole electrodes pad on T1~T4 spinal cord segment level that electrode stimulation of 20 min after. A total of 45 healthy adults participated in the study, who were randomly divided into three groups: 15 of sensory level stimulus group (100 bps, 10~12 mA), 15 of exercise level stimulus group (5 bps, 45~50 mA), 15 of noxious level stimulus group (100 bps, 80~90 mA). Measured items were sympathetic activity and parasympathetic activity. In order to identify the changes in measurement variables before electrode stimulation and after and 30 min stimulation. The comparison of sympathetic and parasympathetic activity in each group revealed that they was changes of after vs 30 min in after electrical stimulation time(p<.05).

Orienting Response of Rats Following Damage to the Mammillary Bodies (유두체가 제거된 흰쥐의 정위반응)

  • Kim, Jong-Kyu;Kim, Chul
    • The Korean Journal of Physiology
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1972
  • A study was planned to see if the mammillary bodies have any influence upon orienting response Thirty-nine male rats were divided into two groups. One group of animals received electrolytic lesion of the mammillary bodies through stereotaxically implanted electrodes (mammillary body group), and the other group received the same treatment short of electrolytic lesion(operated control group). All animals were tested for orienting response 3 weeks after surgery. Orienting response was regarded as elicited when an animal in alertness ceased ongoing activity upon 1,000 Hz tone presentation and/or turned head toward the source of stimulus. Weak (momentary and inconspicuous) and strong (marked and more persistent) responses were discriminated. Occurrence and duration of orienting response were measured, and the rate of habituation was estimated in 20 trials. Shift of attention from sound to light stimulus (10 trials) as well as orienting response of thirsty animals to sound stimulus while drinking (5 trials) and while at rest (5 trials) were also tested. 1. Simple orienting respons to sound stimulus tended to occur more often and its duration tended to be shorter in the mammillary body group than in the operated control group. 2. With repetition of trials, the occurrence of orienting response in each trial decreased progressively in both groups (habituation). However, the rate of habituation was significantly less prominent in the mammillary body group than in the operated control group. 3. Under attention·shift situation, orienting response tended to occur less often and its duration tended to be shorter in the mammillary body group than in the operated control group. 4. Orienting response to sound stimulus while drinking to quench thirst tended to occur more often and its duration tended to be shorter in the mammillary body group than in the operated control group. In quiet state, however, there existed no group difference with regard to the occurrence and duration of the orienting response. Although no obvious inference can be drawn from the above results, they may suggest the mammillary bodies being involved in the orienting response as a control mechanism inhibitory to the occurrence and facilitatory to the habituation of the response.

  • PDF

Effect of defects on lifetime of silicon electrodes and rings in plasma etcher (플라즈마 에쳐용 실리콘 전극과 링의 수명에 미치는 결함의 영향)

  • Eum, Jung-Hyun;Chae, Jung-Min;Pee, Jae-Hwan;Lee, Sung-Min;Choi, Kyoon;Kim, Sang-Jin;Hong, Tae-Sik;Hwang, Choong-Ho;Ahn, Hak-Joon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.2
    • /
    • pp.101-105
    • /
    • 2010
  • Silicon electrode and ring in a plasma etcher those are in contact with harsh plasma suffer from periodic heating and cooling during their lifetime. This causes the silicon components failure due to thermal stress remaining the persistent slip bands (PSBs) on their surfaces. The factors that determine the lifetime of silicon electrode and ring were discussed with respect to silicon ingot. The impurity level and the average defect concentration measured with glow discharge mass spectrometer (GDMS) and microwave photo-conductance decay (${\mu}$-PCD) were compared with the grade of silicon ingots those are divided to slip-free and slip-allowed ingot. Some silp-allowed samples showed planar defects along <110> direction on {001} surface. The role of these defects was suggested from the viewpoint of the lifetime of silicon components.

Evaluation of Cranial Sacral Therapy (CST) Based Pillow on Sleep Induction Using the Electroencephalogram (EEG) (뇌파를 이용한 두개천골요법 기반 베개의 수면유도 효과 검증)

  • Kwon, Hyeok Chan;Phyo, Jung Bin;Park, Yong Gil;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2018
  • The purpose of this study was to investigate the effect of a pillow simulated with cranial sacral therapy (CST) on sleep induction using electroencephalography (EEG). This study included 12 voluntary participants divided into experimental group (CST group) and control group (Non-CST group) to observe EEG changes. The position of the electrode for EEG measurement consists of 8 channels electrodes (Fp1, Fp2, F3, F4, T3, T4, P3 and P4). In this study, we measured the fall asleep time, change of brain activity and sleep wave ratio using EEG wave (${\delta}$, ${\theta}$, ${\alpha}$, ${\beta}$ and ${\gamma}$). As a result, the mean fall asleep time of the experimental group was shorter than that of the control group significantly (p < 0.001). Also in comparison with the control group, both the delta (d) and theta (q) wave corresponding to the slow waves showed a larger increase and the alpha (a) wave showed a larger decrease significantly. The slow waves of experimental group showed a higher rate of significant increase than the control group (p < 0.001). Therefore this study showed that pillow based on CST had an effective in improving sleep induction and quality.