• 제목/요약/키워드: distribution rate

Search Result 7,060, Processing Time 0.033 seconds

Accelerated Life Tests under Uniform Stress Distribution (스트레스함수가 균등분포인 가속수명시험)

  • 원영철
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.2
    • /
    • pp.71-83
    • /
    • 2000
  • This paper presents accelerated life tests for Type I censoring data under probabilistic stresses. Probabilistic stress, $S_j$, is the random variable for stress influenced by test environments, test equipments, sampling devices and use conditions. The hazard rate, ,$theta_j$, is the random variable of environments and the function of probabilistic stress. Also it is assumed that the general stress distribution is uniform, the life distribution for the given hazard rate, $\theta$, is exponential and inverse power law model holds. In this paper, we obtained maximum likelihood estimators of model parameters and the mean life in use stress condition.

  • PDF

A Study on the characteristics of Electron Energy Distribution function of the Radio-Frequency Inductively Coupled Plasma (고주파 유도결합 플라즈마의 전자에너지 분포함수 특성에 관한 연구)

  • 황동원;하장호;전용우;최상태;이광식;박원주;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • Electron temperature, electron density and electron energy distribution function were measured in Radio-Frequency Inductively Coupled Plasma(RFICP) using a probe method. Measurements were conducted in argon discharge for pressure from 10 mTorr to 40 mTorr and input rF power from 100W to 600W and flow rate from 3 sccm to 12 sccm. Spatial distribution of electron temperature, electron density and electron energy distribution function were measured for discharge with same aspect ratio (R/L=2). Electron temperature was found to depend on pressure, but only weakly on power. Electron density and electron energy distribution function strongly depended on both pressure and power. Electron density and electron energy distribution function increased with increasing flow rate. Radial distribution of the electron density and electron energy distribution function were peaked in the plasma center. Normal distribution of the electron density, electron energy distribution function were peaked in the center between quartz plate and substrate. These results were compared to a simple model of ICP, finally, we found out the generation mechanism of Radio-Frequency Inductively Coupled Plasma.

  • PDF

Empirical Prediction Models of 1-min Rain Rate Distribution for Various Integration Time

  • Jung, Myoung-Won;Han, Il-Tak;Choi, Moon-Young;Lee, Joo-Hwan;Pack, Jeong-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.2
    • /
    • pp.84-89
    • /
    • 2008
  • In a wireless channel above microwave frequency, rain attenuation is very important. In order to predict rain attenuation, 1-min. rain rate distribution is required. This paper discusses appropriate conversion methods to estimate 1-minute rain rate from that of other integration time. Based on the measurement data filed in ITU-R WP3J including ETRI data for 6 consecutive years, distributions of rain rate with 1-, 5-, 10-, 20-, 30-minute integration time were analyzed, both on the global and regional basis, and the parametric relationship between the statistical characteristics of 1-minute and other measurement data were investigated to deduce the conversion methods. It is shown that the global model works good with good accuracy for 5-, 10-, 20-min integration time, and the global model is also applicable globally with good accuracy for 5-, 10-, 20-min integration time. The global conversion model was adopted last year as an ITU-R document for new recommendation. The regional conversion model would also be very useful for locations of similar climatic zone.

A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

Distribution of Vibrio alginolyticus inhabiting the Jeju coast (제주 연안에 서식하는 Vibrio alginolyticus 분포)

  • Choi, Won-Sun;Moon, Chan-Yun;Heo, Moon-Soo
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.13 no.1
    • /
    • pp.48-57
    • /
    • 2021
  • Vibrio species are Gram-negative basophils that are ubiquitous in seawater, increasing in number as the water temperature increases. Humans are usually infected by the consumption of contaminated seawater or seafood. V. alginolyticus infection in humans is mainly associated with infections of the skin and ears, such as acute otitis media and cellulitis. In this study, the distribution of V. alginolyticus along the coast of Jeju Island, and its relationship with water temperature, salinity, DO, and pH was investigated. The antibiotic susceptibility of the bacteria isolated was also tested. In seawater, the Daejeong area had the highest detection rate, with 13 cases (21.7%), and the Hallim area showed the lowest detection rate, with eight cases (13.3%) in. In shellfish, the Daejeong area had the highest rate, with seven cases (23.3%), and the Seongsan and Hallim areas had the lowest detection rate, with four cases (13.3%). The overall detection rate was the highest in Daejeong area, with 20 cases (22.2%), and the lowest in the Hallim area, with 12 cases (13.3%). The detection rate was highest when the water temperature was highest.

Flame Structure of Moderately Turbulent Combustion in the Opposed Impinging Jet Combustor (대향분출화염의 분산화학반응 화염구조와 NOx 저감기구)

  • 손민호;조용진;윤영빈;이창진
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1387-1393
    • /
    • 2002
  • The measurement of velocity and stain rate field has been conducted in opposed impinging jet combustion. When a smaller diameter (5mm) orifice of pre-chamber was used, previous studies had reported that the combustion phase showed a shift from weak turbulent combustion to moderate turbulent combustion in the modified Borghi Diagram. In the case with smaller orifice diameter (5mm), NOx emission was substantially reduced by a factor 1/2 while the combustion pressure remains at the same as that in the conventional combustion. Hence, in this study, the experiment setup using PIV technique was designed to identify the relation of the strain rate distribution and NOx reduction associated with moderate turbulent combustion. As a result, it was found that the highly strained pockets are widely distributed during the combustion in the middle of chamber when the orifice diameter is 5mm. And the corresponding PDF distribution of strain rates she was the smoothly distributed strain .ate within the range of |$\pm$1000| (1/sec) rather than a spike shape about zero point. This is the unique feature observed in the combustion with 5mm orifice diameter. Therefore, it can be concluded that the substantial NOx reduction in opposed impinging combustor is mainly attributed to the strain rate distribution within the range of |$\pm$1000|resulting in the combustion phase shift to moderate turbulent combustion.

A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus (중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰)

  • 김민호;천인범;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.

A Numerical Analysis of Flow and Beat Transfer Characteristics of a Two-Dimensional Multi-Impingement Jet(I) (이차원 다중젯트의 유동 및 열전달 특성의 수치적 해석(I) -돌출열원이 없는 경우의 유동특성-)

  • 장대철;이기명
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.58-65
    • /
    • 1995
  • A numerical study for a two dimensional multi-jet with crossflow of the spent fluid has been carried out. Three different distributions of mass-flow rate at 5 jet exits were assumed to see their effects upon the flow characteristics, especially in the jet-flow region. For each distribution, various Reynolds numbers ranging from laminar to turbulent flows were considered. Calculations drew the following items as conclusion. 1) The development of the free jets issued from downstream jets was hindered by the crossflow formed due to jets. Consequently, the free jet was developed into the channel flow without any evident symptom of impingement jet flow characteristics 2) The crossflow induced the pressure gradient along the cross section of jet exits and the value of the pressure gradient increased as going downstream. The crossflow generated also the turbulent kinetic energy as it collied with the downstream jets. 3) The skin friction coefficient along the impingement plate was affected more by the distribution of mass flow rate at jet exits rather than by the Reynolds number. The skin friction coefficient was inversely proportional to the square root of the Reynolds number, regardless of flow regime when a fully developed flow was formed in the jet flow region. 4) The distribution of the skin friction coefficient along the impingement plate was found to be controlled by adjusting the distribution of mass flow rate at jet exits.

  • PDF

Ecological traits and distribution patterns of Osmia spp. in different regions and altitudes in South Korea

  • Kyu-Won Kwak;Kathannan Sankar;Su Jin Lee;Young-Bo Lee;Kyeong Yong Lee
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.47 no.1
    • /
    • pp.25-33
    • /
    • 2023
  • Solitary bees, such as Osmia cornifrons, O. pedicornis, O. satoi, and O. taurus (Hymenoptera: Megachilidae), have the potential for cost-effective and sustainable pollination, necessitating a comprehensive understanding of their ecological traits to implement effective fertilization strategies for various crops. This study investigated the nesting rate of Osmia spp. in different regions and altitudes, using various trap types, and found that the highest nesting rate occurred at altitudes of 300-399 m a.s.l. and showing a preference for bamboo-type traps, with the Andong region having the highest nesting rate overall, indicating the influence of altitude, habitat area, and trap type on the density of Osmia spp. nests. The distribution and diversity of the four Osmia spp. in different regions and altitudes revealed variations in their occurrence, with O. pedicornis having the broadest distribution rate, particularly at altitudes above 300 m a.s.l.. The present study found significant differences between species in the cocoon masses of O. cornifrons, O. pedicornis, and O. taurus, with region and altitude influencing the masses of each species too.

Optimal design of seismic reinforcement for structures with asymmetric rigidity plans using genetic algorithm (유전자 알고리즘을 이용한 비대칭 강성 구조물의 내진보강 최적설계)

  • Lee, Joon-Ho;Kim, Yu-Seong;Sung, Eun-Hee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.2
    • /
    • pp.65-73
    • /
    • 2024
  • In this study, we propose an optimal design method by applying the Prefabricated Buckling Restrained Brace (PF-BRB) to structures with asymmetrically rigidity plan. As a result of the PF-BRB optimal design of a structure with an asymmetrically rigidity plan, it can be seen that the reduction effect of dynamic response is greater in the case of arrangement considering the asymmetric distribution of stiffness (Asym) than in the case of arrangement in the form of a symmetric distribution (Sym), especially It was confirmed that at an eccentricity rate of 20%, the total amount of reinforced PF-BRBs was also small. As a result of analyzing the dynamic response characteristics according to the change in eccentricity of the asymmetrically rigidity plan, the distribution of the reinforced PF-BRB showed that the larger the eccentricity, the greater the amount of damper distribution around the eccentric position. Additionally, when comparing the analysis models with an eccentricity rate of 20% and an eccentricity rate of 12%, the response reduction ratio of the 20% eccentricity rate was found to be large.