• 제목/요약/키워드: distribution System

검색결과 15,353건 처리시간 0.041초

행렬의 역정리를 이용한 전력공급 선로의 상간단락 사고지점 검출 방법 (A Novel Fault Location Method for a Line to Line Fault Using Inverse Theorem of Matrix on Electric Power Lines)

  • 이덕수;최면송;현승호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1321-1324
    • /
    • 2004
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. In this paper, a novel fault location algorithm is suggested for a line to line faults using inverse theorem of matrix on electric power lines. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any electric power system but are particularly useful for unbalanced distribution systems. The simulation results oriented by the real distribution system are presented to show its effectiveness and accuracy.

  • PDF

Influence of Electron and Hole Distribution on 2T SONOS Embedded NVM

  • Choi, Woo Young;Kim, Da Som;Lee, Tae Ho;Kwon, Young Jun;Park, Sung-Kun;Yoon, Gyuhan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.624-629
    • /
    • 2016
  • The influence of electron and hole (EH) distribution on two-transistor (2T) silicon-oxide-nitride-oxide-silicon (SONOS) embedded nonvolatile memory (eNVM) is investigated in terms of reliability. As PE (program/erase) cycles are repeated, it is observed that the electron distribution in the nitride layer becomes wider. It leads to the EH distribution mismatch, which degrades the reliability of 2T SONOS eNVM.

Efficiency Comparison between Chlorine and Chlorine Dioxide to Control Bacterial Regrowth in Water Distribution System

  • Lee, Yoon-Jin
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.282-291
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine and chlorine in order to control microbial regrowth for water distribution systems and select an appropriate disinfection strategy for drinking water systems. The disinfection effects of chlorine and chlorine dioxide with regard to the dosage of disinfectant, contact time and DOC was investigated experimentally. In spite of the consistency of chlorine residuals at approximately 0.2 mg/l, bacteria regrowth was detected in the distribution system and it was confirmed by the scanning electron microscope results. The influence of organic carbon change on the killing effect of chlorine dioxide was strong.

배전용 STATCON 설치 사례-설치 및 평가 (Field Demonstration of the Distribution STATCON-Installation & Evaluation)

  • 차재덕;김준모;홍순욱;이학성;이기선;오관일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2641-2643
    • /
    • 1999
  • This paper describes the first field demonstration of the distribution STATCON in Korea including installation and its evaluation for improving power quality in distribution system. The purpose of installation is to verify functionally the voltage source inverter based equipment for voltage regulation and harmonic mitigation in distribution line. The operational data resulting from field test and the site figure are included.

  • PDF

홉필드 신경회로망을 이용한 배전계통계획의 최적 경로 탐색 (Optimal Routing of Distribution System Planning using Hopfield Neural Network)

  • 김대욱;이명환;김병섭;신중린;채명석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1117-1119
    • /
    • 1999
  • This paper presents a new approach for the optimal routing problem of distribution system planning using the well known Hopfield Neural Network(HNN) method. The optimal routing problem(ORP) in distribution system planning(DSP) is generally formulated as combinational mixed integer problem with various equality and inequality constraints. For the exceeding nonlinear characteristics of the ORP most of the conventional mathematical methods often lead to a local minimum. In this paper, a new approach was made using the HNN method for the ORP to overcome those disadvantages. And for this approach, a appropriately designed energy function suited for the ORP was proposed. The proposed algorithm has been evaluated through the sample distribution planning problem and the simulation results are presented.

  • PDF

타부탐색을 이용한 배전계통 재구성 (Reconfiguration of Distribution System Using Tabu Search)

  • 전영재;최승규;김훈;박경종;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1422-1424
    • /
    • 1999
  • This Paper Presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply tabu search to reconfiguration of distribution system, in this Paper we Propose the several move methods and efficient reconfiguration procedure. We also discuss the tabu search techniques of diversifying the search of solution space as well as the simple tabu search. The experimental results show that the proposed tabu search techniques have the ability to search a good solution.

  • PDF

동적계획법을 이용한 선내 발전시스템의 최적부하분담 방법에 관한 연구 (A Study on Optimal Electric Load distribution of Generators on board using a Dynamic Programming)

  • 유희한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.106-112
    • /
    • 2000
  • Since the oil crisis, we have been concerned about the energy saving techniques of electric generating systems. As a part of the effort to save energy, automatic electric load sharing device was developed. Usually, ship's electric generating system consists of two or three sets of generator. And, electric generating system is operated as single or parallel operation mode according to the demanded electric power. Therefore, it is important to investigate generators operating mode for the supply of required electric power in the ship in order to decrease the operating cost. So, this paper suggests the method to solve the optimal electric load distribution problem by dynamic programming. And, this thesis indicates that the proposed method is superior to the lagrange multiplier's method in obtaining optimal load distribution solution in the ship's electric generating system.

  • PDF

MRV형 LNG선의 선체온도분포 및 증발률 산정에 관한 연구 (A Study on the Computation of Hull Temperature Distribution and Boil off Ratio of MRV Type LNG Carrier)

  • 천병일;김용모;김경근
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.986-996
    • /
    • 1994
  • Insulation system of LNG carrier has made important roles such as maintaining a proper Boil off Ratio(BOR) for the cargo and avoiding the excessive low temperature of the adjacent inner hull beyond the permissible limit. At the same time, safety and economy of the LNG transportation by the ship are connected with the performance of the insulation system. Also, thermal insulation system of LNG carrier is one of the most advanced technique with the structure analysis of tank, welding and assembling. In this study a computer program is developed to calculate the hull temperature distribution and BOR, which are important factors in thermal design for the Moss Rosenberg Verft spherical tank type LNG carrier. Detailed results for hhull temperature distribution close to LNG tank, BOR and the thickness effect of insulation material are reported in this paper in the range of standare design sea condition.

Sheet Molding Compound 금형의 가열채널설계 및 평가기술 (Beating Channel Layout Design and Evaluation Technology for SMC Molds)

  • 허영무;고영배;이종훈;이성희
    • 소성∙가공
    • /
    • 제14권3호
    • /
    • pp.263-268
    • /
    • 2005
  • Heating channel layout design and evaluation technology for SMC molding system was investigated in this work. Traditional rules of cooling channel design in injection molding were applied to the present work. Finite element thermal analysis with $ANSYS^{TM}$ was performed to evaluate the temperature distribution of SHC mold surface. SMC mold was manufactured to evaluate the effect of a proposed heating channel layout system on the temperature distribution of SMC mold surface and infrared camera was applied to a measurement of temperature distribution. It was shown that infrared camera application was possible in a measurement of temperature distribution on SHC mold surface.

기기 수명을 고려한 배전계통 커패시터의 설치 계획 (Optimal Capacitor Placement in a Distribution System Considering Lifetimes of Devices)

  • 박종영;박종근
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.164-171
    • /
    • 2008
  • This paper proposes the planning method for placement of capacitors in a distribution system. The main objectives in the planning for capacitor allocation are the reduction of installation costs and electric power loss. In the proposed method, the life time of each device is considered in calculating installation costs, and the optimal operation status of devices is found by genetic algorithm. Then, the optimal numbers and locations are determined based on the optimal operation status. Simulation results in the 69-bus distribution system show that the proposed method performs better than conventional methods.