• Title/Summary/Keyword: distribution System

Search Result 15,350, Processing Time 0.044 seconds

배전계통의 다양한 이벤트들을 고려한 선로자동화 소프트웨어 개발 (Development of Feeder Automation Software Considering the Diversity Events of Distribution Systems)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.463-470
    • /
    • 2003
  • This paper proposes an expert system, which is able to determine the problem-solving strategy for diversity events occurred on the distribution system. The events include events related to the fault, scheduled outage and optimal operating task such as feeder line fault, line scheduled outage, line overload, system load balancing, system loss minimization, main transformer fault, main transformer scheduled outage, main transformer overload, main transformer protection control. The expert system enhances the reliability of software designed by the integrated concept for the diversity events. The expert system is implemented in C language. And the effectiveness and accuracy for the expert system is verified by simulating the event cases for typical distribution model.

전기저장장치를 이용한 태양광전원이 연계된 배전계통 수용성향상 방안에 관한 연구 (A Study on the Large-scale Adoption Method of Distribution System Interconnected with PV System by Energy Storage System)

  • 남양현;최성식;강민관;이후동;박지현;노대석
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1031-1039
    • /
    • 2018
  • If large-scale PV systems are continuously interconnected to distribution system, customer voltages could violate the allowable voltage limit($220{\pm}13V$) according to reverse power flow of PV system. In order to solve these problems, this paper proposes flexible adoption evaluation algorithm of PV system in distribution system which estimates proper introduction capacity and location of ESS(energy storage system) for keeping customer voltages within allowable voltage limit based on various operating scenarios related with connecting point and capacity of PV system. And also this paper proposes modeling of ESS, SVR(step voltage regulator) and PV system using PSCAD/EMTDC S/W and analyzes characteristics of customer voltages and the adoption ability of PV system in distribution system. From the simulation results, it is confirmed that proposed algorithm is useful for large-scale adoption of PV system in distribution system to maintain customer voltages within allowable voltage limit.

산업단지내 배전계통의 공급신뢰도 및 정전비용 평가 (Evaluation of Reliability and Interruption Cost of Distribution Power System in Industrial Complex)

  • 최상봉;남기영;김대경;정성환;류희석;이재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.95-96
    • /
    • 2006
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate distribution power system reliability by using customer interruption costs. Accordingly, it is increased for methodology to evaluate distribution power system reliability in power supply zones under competitive electricity market. This paper presents algorithm to evaluate system average interruption duration index. expected energy not supplied and system outage cost taking Into consideration failure rate of distribution facility and industrial customer interruption cost. Also, to apply this algorithm to evaluate system outage cost presented in this paper, distribution system of a dual supply system consisting of mostly high voltage customers in industrial complex in Korea is used as a sample case study. Finally, evaluation results of system interruption cost, system average interruption duration index and expected energy not supplied in sample industrial complex area are shown in detail.

  • PDF

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

태양광 발전과 연계된 직류배전 시스템의 특성연구 (Characteristics Study of DC Distribution System Interconnected with PV System)

  • 서현욱;변병주;이영진;김동진;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.201-202
    • /
    • 2011
  • Existing AC distribution system lower the efficiency of the commercial power, and also generate the conversion loss of renewable energy. In this study, DC distribution system interconnected with PV system is produced, and it is studied about characteristics of the system through the experiments which are uesd load of 3[kW].

  • PDF

Reliability Equivalence Factors of a Series - Parallel System in Weibull Distribution

  • El-Damcese, M.A.;Khalifa, M.M.
    • International Journal of Reliability and Applications
    • /
    • 제9권2호
    • /
    • pp.153-165
    • /
    • 2008
  • This paper discusses the reliability equivalences of a series-parallel system. The system components are assumed to be independent and identical. The failure rates of the system components are functions of time and follow Weibull distribution. Three different methods are used to improve the given system reliability. The reliability equivalence factor is obtained using the reliability function. The fractiles of the original and improved systems are also obtained. Numerical example is presented to interpret how to utilize the obtained results.

  • PDF

배전계토에서의 안전도 평가를 위한 전문가 시스 (An Expert System for Security Assessment in Distribution System)

  • Park, Byoung-youn;Kim, Se-Ho;Moon, Young-Hyun
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.179-188
    • /
    • 1994
  • This paper deals with implementation of an expert system to obtain an optimal plan of load transfer for fault restoration with the capability of security monitoring and assessment in distribution systems. Based on the technique of load transfer tree analysis, the proposed expert system can afford to assist system operators in proposing an optimal plan of load transfer for fault restoration, In paticular, an application of the proposed ES to practical distribution systems yields an optimal load transfer plan which ensures system security by considering security assessment for contingency of feeders and main transformers in the knowledge based sense.

전기철도 고압배전시스템의 공급신뢰도 향상 방안 연구 (Improvement Method of Supplying Reliability on the Electric Railway Power Distribution System)

  • 김영선;창상훈;김왕곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.682-687
    • /
    • 2005
  • High quality power supplying of power distribution system in electric railway system is the important function. Power feeding system is complicated witch is compose with distribution line, circuit break, protection facilities and so on. Among this components, role of substation is most important for elevation of reliability in electric power system. Therefore, the enhanced reliability considering the preventive inspection, repair work, replacement is necessary. In this study, a proposed the enhanced reliability method through a calculation of fault probability in power feeding system.

  • PDF

열화상 이미지 분석을 통한 배전 설비 공정능력지수 감지 시스템 개발 (Identifying Process Capability Index for Electricity Distribution System through Thermal Image Analysis)

  • 이형근;홍용민;강성우
    • 품질경영학회지
    • /
    • 제49권3호
    • /
    • pp.327-340
    • /
    • 2021
  • Purpose: The purpose of this study is to propose a system predicting whether an electricity distribution system is abnormal by analyzing the temperature of the deteriorated system. Traditional electricity distribution system abnormality diagnosis was mainly limited to post-inspection. This research presents a remote monitoring system for detecting thermal images of the deteriorated electricity distribution system efficiently hereby providing safe and efficient abnormal diagnosis to electricians. Methods: In this study, an object detection algorithm (YOLOv5) is performed using 16,866 thermal images of electricity distribution systems provided by KEPCO(Korea Electric Power Corporation). Abnormality/Normality of the extracted system images from the algorithm are classified via the limit temperature. Each classification model, Random Forest, Support Vector Machine, XGBOOST is performed to explore 463,053 temperature datasets. The process capability index is employed to indicate the quality of the electricity distribution system. Results: This research performs case study with transformers representing the electricity distribution systems. The case study shows the following states: accuracy 100%, precision 100%, recall 100%, F1-score 100%. Also the case study shows the process capability index of the transformers with the following states: steady state 99.47%, caution state 0.16%, and risk state 0.37%. Conclusion: The sum of caution and risk state is 0.53%, which is higher than the actual failure rate. Also most transformer abnormalities can be detected through this monitoring system.

배전 종합 자동화 시스템의 현장 실증시험 연구 (A study on field trial systems for distribution automation in KEPCO)

  • 이원빈;신창우;양완식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.619-624
    • /
    • 1987
  • A study on distribution automation system suitable to distribution system of KEPCO has started since 1984, and the field trial system for ADS will be operated for testing. This paper will describe project and planning for field trial of KEPCO.

  • PDF