• Title/Summary/Keyword: distribution System

Search Result 15,353, Processing Time 0.045 seconds

DIFFUSION APPROXIMATION OF TIME DEPENDENT QUEUE SIZE DISTRIBUTION FOR $M^X$/$G^Y$/$_c$ SYSTEM$^1$

  • Choi, Bong-Dae;Shin, Yang-Woo
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.2
    • /
    • pp.419-438
    • /
    • 1995
  • We investigate a tansient diffusion approximation of queue size distribution in $M^{X}/G^{Y}/c$ system using the diffusion process with elementary return boundary. We choose an appropriate diffusion process which approxiamtes the queue size in the system and derive the transient solution of Kolmogorov forward equation of the diffusion process. We derive an approximation formula for the transient queue size distribution and mean queue size, and then obtain the stationary solution from the transient solution. Accuracy evalution is presented by comparing approximation results for the mean queue size with the exact results or simulation results numerically.

  • PDF

A Comparison of the performance of mean, median, and precedence control charts for nonnormal data

  • Kim, Jung-Hee;Lee, Sung-Im;Park, Heon-Jin;Lee, Jae-Cheol;Jang, Young-Chul
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.05a
    • /
    • pp.197-201
    • /
    • 2005
  • In this article, we will compare the performance of the mean control chart, the median control chart, the transformed mean control chart, the transformed median control chart, and the precedence control chart by simulation study. For control charts with transformed data, Yeo-Johnson transformation is used. Under the in-control condition, ARL's in all control charts coincide with the designed ARL in the normal distribution, but in the other distributions, only the precedence control chart provides the in-control ARL as designed. Under the out-of-control condition, the mean control chart is preferred in the normal distribution and the median control chart is preferred in the heavy-tailed distribution and the precedence control chart outperforms in the short-tailed distribution.

  • PDF

A Study on the Reliability of Helical Gear System Using Renewal Theory (재생이론에 의한 헬리컬 기어장치의 신뢰성에 관한 연구)

  • 김하수;양성모
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.90-96
    • /
    • 1998
  • Helical gear system is widely used to transmit heavy duty power with harmonies and silences between parallel shafts. This paper predicts a life with Weibull distribution and estimates a reliability based on recycle principle of helical gear systems. 2-parameter Weibull distribution is generally adopted to estimate the mechanical life and the reliability of most gear systems, because this Weibull distribution is proper to explain a characteristics or a life of parts of gear systems with linearity of probability density data on weibull data sheet. For a high reliability, this paper estimates a number of overhaul times and a number of needed substitutes (exchange attachment,1 or parts) with following renewal theory, One is make an exchange of whole module include failure attachments/parts and second estimating method is only exchange of a failure attachments / parts.

  • PDF

Extraction Rate and Temperature Dependency of Distribution Ratio of 4f and 5f Series Element in the Various Phosphorus Compounds (各種 燐化合物溶媒 抽出系에 있어서 4f 및 5f 系列 元素의 抽出速度 및 分配率의 溫度依存性)

  • Rhee, Chin-Taik
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.199-204
    • /
    • 1969
  • The distribution rate of 4f and 5f series elements in chelate and ion association extraction system was studied. Clear difference between lighter and heavier part of 4f series are observed. Trivalent Am and Cm were appeared to be grouped into the lighter part of 4f series. And also the variation of distribution ratio according to the varied temperature was studied. The variation modes of distribution ratio are different according to the extraction system. Atomic number dependence in the chelate extraction system was observed.

  • PDF

Loss Reduction in Heavy Loaded Distribution Networks Using Cyclic Sub Tree Search (순환적 부분트리 탐색법을 이용한 중부하 배전계통의 손실최소화)

  • Choi, Sang-Yule;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.241-247
    • /
    • 2001
  • Network reconfiguration in distribution systems is realized by changing the status of sectionalizing switches, and is usually done for loss reduction of load balancing in the system. This paper presents an effective heuristic based switching scheme to solve the distribution feeder loss reduction problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to apply a proposed technique called cyclic best first search. the proposed algorithm identify the most effective the set of switch status configuration of distribution system for loss reduction. To demonstrate the validity of the proposed algorithm, numerical calculations are carried out the 32, 69 bus system models.

  • PDF

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

Development of the Discrimination Algorithm for Event and Variation in Distribution System Using S-transform (S-transform을 이용한 배전계통의 이벤트와 변동 판별 알고리즘 개발)

  • Lee, Soon-Jeong;Seo, Hun-Chul;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.657-663
    • /
    • 2012
  • Recently, by increasing of devices which are sensitive to power quality, the deterioration of power quality has been accelerated. For this reason, the social and economic losses are increased. So not only correct measurement and evaluation, but also countermeasure for improvement of power quality is surely necessary for both electric power supplier and consumer. In this paper, the discrimination algorithm for events and variation occurred in distribution systems using S-transform is proposed. Firstly, we review for events and variations that occur in distribution system. Next, we simulate events and variations on various conditions using ElectroMagnetic Transient Program(EMTP). For the simulation, the IEEE 13 Node Test Feeder and KEPCO's distribution system is modeled. Finally, for the analysis, a modified wavelet transform known as S-transform is adopted to find out the characteristics of each events and variations.

A Study on the Substation Reliability Assessment Using Weibull Distribution (와이블분포를 이용한 변전소 신뢰도 평가에 관한 연구)

  • Kim, Gwang-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.7-14
    • /
    • 2002
  • In power system study, relibility assessment has been an important topic during past several decards because sudden power interruption can bring about enormous economic loss. although the size of a substation is smaller than that of generation system or transmission system, switching actions after fault(s) make reliability assessment of substation rather complex situations such as switching actions easily and permit various probability distributions in describing substation elements. Despite this ability of Monte Carlo simulation, one-parameter exponential distribution is still popular in this reliability assessment. This paper examines the characteristics of several two-parameter probability distributions, and offers new parameter decision rule based on average and variance of the target to be modelled. In case study, this paper shows the profits by using Weibull distribution which is one of two-parameter probabilistic distributions instead of exponential one.

Application of Ant colony Algorithm for Loss Minimization in Distribution Systems (배전 계통의 손실 최소화를 위한 개미 군집 알고리즘의 적용)

  • Jeon, Young-Jae;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.4
    • /
    • pp.188-196
    • /
    • 2001
  • This paper presents and efficient algorithm for the loss minimization by automatic sectionalizing switch operation in distribution systems. Ant colony algorithm is multi-agent system in which the behaviour of each single agent, called artificial ant, is inspired by the behaviour of real ants. Ant colony algorithm is suitable for combinatiorial optimization problem as network reconfiguration because it use the long term memory, called pheromone, and heuristic information with the property of the problem. The proposed methodology with some adoptions have been applied to improve the computation time and convergence property. Numerical examples demonstrate the validity and effectiveness of the proposed methodology using a KEPCO's distribution system.

  • PDF

Back Fed Earth Fault Detection in Three Wire-Unigrounded Distribution-System By Zero Sequence Admittance (영상어드미턴스에 의한 직접접지 배전방식에서의 역가압 지락사고 검출)

  • Yoo, Myeong-Ho;Kim, Il-Dong;Han, Hong-Seok;Pak, Chul-Won
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.120-123
    • /
    • 1993
  • This paper presents the developing a new algorithm for detecting the Back fed Earth Fault in three wire-unigrounded distribution system by zero sequence admittance. So called "Backfed Earth Fault" of the electric power distribution line refers to a class of earth faults that the load-side line only is grounded, following after the distribution line broken into two parts, the source-side and the load-side. Because its mechanism differs from that of other earth faults, it is therefore, required to examine. This paper deals with the detailed software of the digital protective relay for Backfed earth fault. In order to prove that the proposed schemes is good, we performed off-line simulation using data from EMTP and ETSA(Electrcity Trust Of South Austrilia). It is shown that the suggested algorithm is never mal operated.

  • PDF