• 제목/요약/키워드: distortion of paper record

검색결과 11건 처리시간 0.031초

마이크로프로세서를 이용한 AOC 방식에서 EOG 앰프 성능 개선 (Improvement of the performance of EOC Amp in AOC method using microprocessor)

  • 고석남;이상세;정호춘;임승관;이영석;진달복;박병림
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.218-221
    • /
    • 2000
  • The electronystagmography(ENG) means to measure and record CRP(Corneal-Retinal Potential) whenever the eyeball is moved by using a skin electrode stuck to the hi-temporal and the difference of CRP. Both the horizontal and vertical movement are known according to the position of the stuck skin electrode. In this paper, the variable time-constances to record the eyeball signal of the conventional EOG(Electro-Oculograph) Amplifier is chosen. The shorter the time-constance is, the worse the distortion of a signal is. But the unbalanced impedance of the electrode stuck on the hi-temporal is reduced. Also, the longer the time-constance is, the less the distortion of it signal is. But it is sensitive to the change of base line according to the unbalanced impedance. In order to solve these problems, an DC-Amplifier, the distortion of the eyeball signal is globally used. By solving unbalanced impedance problem of EOG amplifier, the distortion ratio of EOG amplifier is improved.

  • PDF

지수창함수를 사용한 임팩트햄머 실험에서 주파수응답함수의 왜곡과 개선책 (FRF Distortion Caused by Exponential Window Function on Impact Hammer Testing and Its Solution)

  • 안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.334-340
    • /
    • 2003
  • Exponential window function Is widely used In impact hammer testing to reduce leakage error as well as to get a good S/N ratio. The larger its decaying rate is, the more effectively the leakage errors are reduced. But if the decay rate of the exponential window is too large, the FRF is distorted. And the modal parameters of the system can not be exactly identified by modal analysis technique. Therefore, it is a difficult problem to determine proper decay rate in impact hammer testing. In this paper, amount of the FRF distortion caused by exponential window is theoretically uncovered. A new circle fitting method is also proposed so that the modal parameters are directly extracted from impulse response spectrum distorted by the exponential-windowed impulse response data. The results by the conventional and proposed circle fitting method are compared through a numerical example.

Adaptive data hiding scheme based on magic matrix of flexible dimension

  • Wu, Hua;Horng, Ji-Hwei;Chang, Chin-Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권9호
    • /
    • pp.3348-3364
    • /
    • 2021
  • Magic matrix-based data hiding schemes are applied to transmit secret information through open communication channels safely. With the development of various magic matrices, some higher dimensional magic matrices are proposed for improving the security level. However, with the limitation of computing resource and the requirement of real time processing, these higher dimensional magic matrix-based methods are not advantageous. Hence, a kind of data hiding scheme based on a single or a group of multi-dimensional flexible magic matrices is proposed in this paper, whose magic matrix can be expanded to higher dimensional ones with less computing resource. Furthermore, an adaptive mechanism is proposed to reduce the embedding distortion. Adapting to the secret data, the magic matrix with least distortion is chosen to embed the data and a marker bit is exploited to record the choice. Experimental results confirm that the proposed scheme hides data with high security and a better visual quality.

다중대역-디지탈 수동혼변조왜곡 측정시스템 개발 (Implementation of MultiBand-Digital Passive InterModulation Distortion Measurement System)

  • 박기원;신동환;이영철
    • 한국전자통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.1193-1200
    • /
    • 2016
  • 본 논문에서는 광대역 특성을 갖는 이동통신 RF 모듈의 수동혼변조왜곡신호를 측정할 수 있는 시스템을 개발하였다. 광대역 특성을 나타내기 위하여 RF 수신단에서 저 잡음 특성과 광대역 특성을 만족하는 수신기를 설계하였으며 RF 수신 단에서 넓은 동적영역(high dynamic range)을 나타내도록 하였다. 설계된 수동혼변조왜곡 측정시스템에서 FPGA/DSP를 적용하여 측정된 PIMD신호를 PC에 기록하도록 프로그램 하였다. 650MHz-2700MHz 까지 가변하여 PIMD3를 측정하여 최고 -138dBc를 나타내었다.

수사관의 심증이 조서의 왜곡에 미치는 영향 (The Effect of Investigator's Belief about Veracity of Suspect on Distortions of Paper Records)

  • 이형근;조은경;이미선
    • 한국심리학회지:법
    • /
    • 제11권3호
    • /
    • pp.267-285
    • /
    • 2020
  • 진술증거는 범죄수사와 형사재판에서 사실을 확정하는 데 사용되는 중요한 증거방법 중 하나다. 현행 형사소송법은 피의자 등의 진술을 조서에 기록한 후, 일정한 요건 하에 그 조서를 재판의 증거로 사용하도록 하고 있다. 그런데 조서에 각종 왜곡이 있어 실체적 진실발견을 저해한다는 지적이 지속적으로 제기되고 있다. 이에 본 연구는 조서작성 단계에 관한 실험연구를 통해 조서 왜곡의 원인으로 거론되는 요인 중 '수사관의 심증'이 갖는 효과를 밝혀 보고자 하였다. 참여자는 경찰수사관 90명이었고, 참여자들을 유죄심증, 무죄심증 및 중립심증의 세 가지 조건에 30명씩 할당한 후, 모의 신문영상을 보면서 조서를 작성하도록 하였다. 연구 결과, 유죄심증 집단이 무죄심증 및 중립심증 집단보다 조서를 더 많이 왜곡한다는 사실, 조서의 왜곡은 조작 형태보다 생략 형태가 더 빈번하다는 사실, 신문사항의 특성에 따라 왜곡의 빈도가 다르다는 사실 등이 확인되었다. 논의에서는 수사기록에 의한 심증 처치, 조서 왜곡의 코딩 기준 마련 등 연구의 의의와 모의 신문상황의 규범적·현실적 타당도 결여 등 연구의 제약점을 설명하고, 약간의 정책적 제언을 첨언하였다.

  • PDF

한국의료패널을 활용한 고혈압환자의 복약순응도가 의료이용 및 의료비 지출에 미치는 영향 분석 (Relationship between Antihypertension Medication Adherence, Medical Utilizations, and Medical Expenditure Among Patients with Hypertension)

  • 김성옥;장선미
    • 약학회지
    • /
    • 제57권5호
    • /
    • pp.369-375
    • /
    • 2013
  • Objective: Using the Korean Health Panel data (KHP) of 2008 and 2009, this paper analyzed the effect of antihypertension medication adherence on the changes in medical service utilization and medical expenditure in the next year. Method: Through a face-to-face interview survey, KHP has provided an extensive data on demographic characteristics, medical utilizations behavior, medical expenditure and health behaviors of the targeted households and their members since 2008. KHP is recognized as highly accurate regarding medical expenditure in that it makes the target households to record 'Health diary' whenever they use healthcare service, which could minimize their cognitive bias or memory distortion. The 2010 KHP data was based on the interview from 6,432 households and 19,697 household members. Two part model was used to explore the effects of medication adherence on medical use (logistic regression analysis) and medical expenditures (OLS). Result: Our study result demonstrated that the 74.7% of the patients who strictly adhere to their medication in both years, in 2008 and in 2009, were likely to use inpatient service in 2010. This shows the noncompliant patients were in fact use emergency service less than the compliant patients. Conclusion: Based on our analysis, this paper concludes that the high medication adherence of hypertensive patients could contribute to reduce the emergency service use. Therefore it is highly recommendable for the Korean government and the insurer, NHIS, to actively invest in developing education and promotion program to improve medication adherence among hypertensive patients.

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

불균형 데이터 집합에 대한 스마트 분류방법과 특허 평가에의 응용 (Smarter Classification for Imbalanced Data Set and Its Application to Patent Evaluation)

  • 권오병;이상연
    • 지능정보연구
    • /
    • 제20권1호
    • /
    • pp.15-34
    • /
    • 2014
  • 성과 지표로서의 전방적 정확도는 정답인 경우 1, 오답인 경우 0으로 계사하는 이른바 모듈화된 정확도를 충분히 고려하지 못한다. 이에 문제의 특징에 따라 모듈화 정확도에 맞는 판별 규칙을 최적화 하는 보다 스마트한 판별 알고리즘이 필요하다고 볼 수 있다. 이에 따라, 스마트한 알고리즘은 문제 유형에 따라 보다 일반화되고 실제 성능의 왜곡을 야기할 수 있는 이산화에 제약되지 않아야 한다. 따라서 본 논문의 목적인 모듈화 정확도를 개선하는 새로운 부스팅 알고리즘을 제안하는 것이다. 이에 일반화를 도모하고 문제 영역의 특성에 맞게 판별화 모형을 선정하기 위해 스마트함을 고려한 모형 선정 알고리즘을 개발하였다. 제안된 방법의 성능을 검증하기 위해 실제로 47,000여건의 특허건을 가지고 실제 실용화 가능성을 판별하는 실험을 수행하였다.

의료자산보호에서 얼굴인식을 위한 가보 웨이블릿 분석 (Gabor Wavelet Analysis for Face Recognition in Medical Asset Protection)

  • 전인자;정경용;이영호
    • 한국콘텐츠학회논문지
    • /
    • 제11권11호
    • /
    • pp.10-18
    • /
    • 2011
  • 개인정보보호법의 시행은 의료기관에서 의료자산에 대한 보안이 중요시 되고 있으며 이를 위한 얼굴인식은 가장 흥미롭지만 다양한 문제점을 가지고 있는 요소 중의 하나이다. 얼굴인식은 얼굴 영상의 변화하는 요인인 포즈, 조명, 표정과 크기의 변화요소를 포함하고 있다. 이와 같은 변화 요인 중에서 빛의 위치와 방향의 변화요인이 가장 큰 어려움중의 하나이다. 이와 같은 단점을 극복하기 위하여 본 논문에서는 의료자산 보호를 위한 CCTV 관제에서 얼굴인식을 위하여 가보웨이블릿의 계수의 분석, 커널 선정, 특징점, 커널크기와 같은 요소를 분석하였다. 제안된 방법은 분석으로 구성되어있다. 첫 번째 분석은 이미지로부터 커널을 선정하기 위한 것이며, 두 번째 분석은 커널 크기에 대한 계수 분석이다. 마지막으로 입력 영상의 크기에 따른 가보커널 크기의 변화에 대한 측정이다. 실험을 통하여 도출된 계수를 이용하여 얼굴인식을 수행하였으며, 평균 97.3%라는 인식 결과를 도출하였다. 제안하는 방법을 개발하여 논리적 타당성과 유효성을 검증하기 위해 실험적인 적용을 시도하고자 한다. 따라서 얼굴인식에서 서비스의 만족도와 질을 향상시켰다.

컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현 (Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface)

  • 이한;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.678-681
    • /
    • 2003
  • 컴팩트 플래쉬방식의 휴대용산소포화도와 ECG감시 시스템을 구현하는데 목적이 있다. 먼저 휴대용 산소포화도의 측정은 산소포화도와 맥박을 동시에 측정해서 2채널을 기록하도록 설계했다. 다른 장치없이 환자의 상태를 감지할 수 있고 소형화되고 휴대 가능하게 했다. 환자모니터링에 의해 발생하는 문제점을 해결하기 위해 기저선변동을 없애기 위해 2D 섹터 알고리즘을 적용시킨 아날로그 보정회로를 추가했다. 현재 SpO2모듈은 완성됐지만 컴팩트 플래쉬 방식을 사용하는데는 아직까지 많은 개선의 여지가 있다. ECG감시장치는 3극자 ECG시스템을 적용했다. 필터로는 2가지가 혼합된 방식이다. 하나는 전력선을 없애는 것이고 다른 하나는 기저선 변동을 없애는 것이다. 이것은 DC간섭을 줄이고 전력선의 주파수 간섭을 없애는 효과가 있다. 컴팩트플래쉬 방식으로 환자의 정보를 적은 비용으로 쉽게 기록하고 의료기관에 알릴수 있다.

  • PDF