• Title/Summary/Keyword: distilled water

Search Result 2,421, Processing Time 0.024 seconds

Evaluation of microplastic in the inflow of municipal wastewater treatment plant according to pretreatment methods (전처리 방법에 따른 하수처리장 유입수에서의 미세플라스틱 성상분석 평가)

  • Kim, Sungryul;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.83-92
    • /
    • 2022
  • The amount of the plastic waste has been increasing according to global demand for plastic. Microplastics are the most hazardous among all plastic pollutants due to their toxicity and unknown physicochemical properties. This study investigates the optimal methodology that can be applied to sewage samples for detecting microplastics before discussing reducing microplastics in MWTPs. In this study, the effect of different pretreatment methods while detecting microplastic analysis of MWTP influent samples was investigated; the samples were collected from the J sewage treatment plant. There are many pretreatment methods but two of them are widely used: Fenton digestion and hydrogen peroxide oxidation. Although there are many pretreatment methods that can be applied to investigate microplastics, the most widely used methods for sewage treatment plant samples are Fenton digestion and H2O2 oxidation. For each pretreatment method, there were factors that could cause an error in the measurement. To overcome this, in the case of the Fenton digestion pretreatment, it is recommended to proceed with the analysis by filtration instead of the density separation method. In the case of the H2O2 oxidation method, the process of washing with distilled water after the reaction is recommended. As a result of the analysis, the concentration of microplastics was measured to be 2.75ea/L for the sample using the H2O2 oxidation method and 3.2ea/L for the sample using the Fenton oxidation method, and most of them were present in the form of fibers. In addition, it is difficult to guarantee the reliability of measurement results from quantitative analysis performed via microscope with eyes. A calibration curve was created for prove the reliability. A total of three calibration curves were drawn, and as a result of analysis of the calibration curves, all R2 values were more than 0.9. This ensures high reliability for quantitative analysis. The qualitative analysis could determine the series of microplastics flowing into the MWTP, but could not confirm the chemical composition of each microplastic. This study can be used to confirm the chemical composition of microplastics introduced into MWTP in the future research.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Effect of various surface treatment methods of highly translucent zirconia on the shear bond strength with resin cement (고투명도 지르코니아의 다양한 표면처리 방법이 레진시멘트와의 전단결합강도에 미치는 영향)

  • Yu-Seong Kim;Jin-Woo Choi;Hee-Kyung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.179-188
    • /
    • 2023
  • Purpose. The purpose of this study was to evaluate the effect of surface treatments on the shear bond strength of two types of zirconia (3-TZP and 5Y-PSZ) with resin cement. Materials and methods. Two different types of zirconia specimens with a fully sintered size of 14.0×14.0×2.0 mm3 were prepared, polished with 400, 600, and 800 grit silicon carbide paper, and buried in epoxy resin. They were classified into four groups each control, sandblasting, primer, and sandblasting & primer. Cylindrical resin adhered to the surface-treated zirconia with resin cement. It was stored in distilled water (37℃) for 24 hours, and a shear bond strength test was performed. The normality of the experimental group was confirmed with the Kolmogorov-Smirnov & Shapiro-Wilk test. The interaction and statistical difference were analyzed using a two-way ANOVA. A post-hoc analysis was performed using Dunnett T3. Results. As a result of two-way ANOVA, there was no significant difference in shear bonding strength between zirconia types (P > .05), but there was a significant correlation in the sandblasting, primer, and alumina sandblasting & primer group (P < .05). Dunnett T3 post-test showed that, regardless of the type of zirconia, shear bonding strength was sandblasting & primer > Primer > sandblasting > control group (P < .05). Conclusion. There was no difference in shear bond strength between the types of zirconia. The highest shear bond strength was shown when the mechanical and chemical treatments of the zirconia surface was performed simultaneously.

Antioxidant and Anti-Inflammatory Effects on Optimal Extraction Conditions of Different Edible Parts of Perilla (Perilla frutescens L.) (들깨 가식부위별 최적 추출 조건 확립을 위한 항산화 및 항염증 활성 평가)

  • Min Young Kim;Jung In Kim;Sang Woo Kim;Sungup Kim;Eunyoung Oh;Jeongeun Lee;Eunsoo Lee;Yeon Ju An;Myoung Hee Lee;Choon-Song Kim
    • The Korean Journal of Food And Nutrition
    • /
    • v.36 no.6
    • /
    • pp.551-560
    • /
    • 2023
  • This study was performed to investigate antioxidant and anti-inflammatory activities of perilla(Perilla frutescens L.) seed, flower and leaf according to extraction condition. Perilla seed extracts(PSE), perilla flower extracts(PFE), perilla leaf extracts(PLE) was extracted by stirring extraction (STE, 25℃), shaking extraction (SHE, 80℃), and sonication assisted extraction(SAE, 25℃) with 94% ethanol, 60% ethanol and distilled water, followed by analysis of total polyphenol and flavonoid and testing radical scavenging activities. The highest total polyphenol content (5.47, 9.36, 38.58 mg gallic acid equivalent/g), total flavonoid content(5.77, 8.62, 46.44 mg catechin equivalent/g), ABTS(10.68, 19.46, 63.56 mg trolox equivalent/g) and DPPH(6.51, 7.69, 79.73 mg trolox equivalent/g) radical scavenging activity of PSE, PFE and PLE was observed in the HWE with 60% ethanol,. Among the three extraction method, SHE provided the best results for yield, polyphenol, flavonoid content of perilla seed, flower, leaf in comparison to STE or SAE. SHE with 60% ethanol of perilla seed, flower, leaf more effectively inhibited secretion of nitric oxide(NO) and pro-inflammatory cytokine in RAW 264.7 macrophage exposed to LPS compared to other extraction solvent and method. Therefore, these extracts obtained from perilla seed, flower, leaf could be used antioxidant and anti-inflammatory ingredients in the food industry.

Study on the Mechanical Stability of Red Mud Catalysts for HFC-134a Hydrolysis Reaction (HFC-134a 가수분해를 위한 Red mud 촉매 기계적 안정성 향상에 관한 연구)

  • In-Heon Kwak;Eun-Han Lee;Sung-Chan Nam;Jung-Bae Kim;Shin-Kun Ryi
    • Clean Technology
    • /
    • v.30 no.2
    • /
    • pp.134-144
    • /
    • 2024
  • In this study, the mechanical stability of red mud was improved for its commercial use as a catalyst to effectively decompose HFC-134a, one of the seven major greenhouse gases. Red mud is an industrial waste discharged from aluminum production, but it can be used for the decomposition of HFC-134a. Red mud can be manufactured into a catalyst via the crushing-preparative-compression molding-firing process, and it is possible to improve the catalyst performance and secure mechanical stability through calcination. In order to determine the optimal heat treatment conditions, pellet-shaped compressed red mud samples were calcined at 300, 600, 800 ℃ using a muffle furnace for 5 hours. The mechanical stability was confirmed by the weight loss rate before and after ultra-sonication after the catalyst was immersed in distilled water. The catalyst calcined at 800 ℃ (RM 800) was found to have the best mechanical stability as well as the most catalytic activity. The catalyst performance and durability tests that were performed for 100 hours using the RM 800 catalyst showed thatmore than 99% of 1 mol% HFC-134a was degraded at 650 ℃, and no degradation in catalytic activity was observed. XRD analysis showed tri-calcium aluminate and gehlenite crystalline phases, which enhance mechanical strength and catalytic activity due to the interaction of Ca, Si, and Al after heat treatment at 800 ℃. SEM/EDS analysis of the durability tested catalysts showed no losses in active substances or shape changes due to HFC-134a abasement. Through this research, it is expected that red mud can be commercialized as a catalyst for waste refrigerant treatment due to its high economic feasibility, high decomposition efficiency and mechanical stability.

Activities of the Hydrolytic Enzymes Produced by Plant Pathogenic Fungi, Sclerotium rolfsii, Sclerotinia Sclerotinia and Sclerotiorum, and Helminthosporium sigmoideum var. irregulare (수종의 식물병원균(흰비단병균$\cdot$균핵병균 및 좀검은 균핵병균)이 생산하는 가수분해효소의 활성)

  • Cho B. H.;Kim K.
    • Korean journal of applied entomology
    • /
    • v.16 no.4 s.33
    • /
    • pp.199-208
    • /
    • 1977
  • Activities of various hydrolytic enzymes produced by three plant pathogenic fungi, Sclerotium rolfsii Sacc., Sclerotinia sclerotiorum (Lieb.) deBary and Helminthosporium sigmoideum var. irregulare Crallery et Tullius, were measured. Activties and amounts of the enzymes in mycelia, cultural filtrates, and sclerotia(except of sclerotia of H. sigmoideum var. irregulare) were estimated at various pH levels in order to find out optimal pH for their enzymatic activities. Enzymes such as cellulase (ex), invertase, xylanase, $\beta-amylase$, polymethylgalacturonase, polygalacturonase, phosphatase and protease were estimated. Culture solution for production of enzymes was prepared by adding of 10g, D-glucose, 1.3g $NH_4NO_3,\; 0.5g\; MgSO_4,\;7H_2O,\; and\; 1.0g\; KH_2PO_4$ into 1 liter of potato decoction plus 2ml of micro element solution consisting of 0.2mg. Fe, 0.2mg Zn, and 0.1mg Mn as the sulphates into 1 liter of distilled water. All tested mycelia and cultural filtrates were obtained from the cultures incubarted in previous solution for ten days at $25^{\circ}C$, and sclerotia were harvested from PDA plates of 3. days old, The crude enzyme solutions were prepared according to the method of Miyazaki etal. Ten days after incubation, activities of Cx produced by Scl. sclerotiorum were higher than those of the other fung and each of Cx from three fungi showed different pH optima, such as S. rolfsii and Scl. schlerotiorum in acid side (around pH 3.0), H. sigmoideum var. irregulare in neutral side (around pH 6.3). Invertase activities of S. rolfsii were 20 times higher than those of the other fungi in all samples. All tested fungi, however, showed no significant difference between the enzymatic activities of their cultural filtrate and mycelia and the activities in sclerotia of S. rolfsii and Scl. sclerotiorum were hardly recognized. There were multiple peaks on the xylanase activity curves of three fungi in terms of pH values. High activities of the xylanase were revealed in sclerotia of S. rolfsii and Scl. sclerotiorum, and in mycelia of H. sigmoideum var. irregulare. The highest activities of $\beta-amylase$ were shown both in mycelia and cultural filtrate of H. sigmoideum var. irregulae among the tested fungi, and their optimal pH was 6.2 in both mycelia and cultural filtrate. In the S. rofsii and Sel. sclerotiorum, however, the activities of cultural filtrates were higher than those of the other fungi, and optimal pH was 3.0 and 6.2 for cultural filtrate and both mycelia and sclerotia, respectively. Activities of PMG were high in cultural filtrates of all tested fungi, especially in Scl. sclerotiorum and H. sigmoideum var. irregulare. Mycelia of themalso showed the considerable activities. Optimal pH for enzymatic activities were variable with thekind of fungi or with the samples measured. The highest activities of PG were presented by mycelia of S. rolfsii and Scl. sclerotiorum. $9.l\mu /min.\; and\; 9.5\mu g/min.$, respectively. Optimal pH for activity of PG in mycelia was around 4.5 in S. rolfsii and around 3.0 in Scl. sclerotiorum. Phosphatase of S. rolfsii and Scl. sclerotiorum was more active in acid side (optimal PH3. 5) and that of H. sigmoideum var. irregulare showed one peak each in acid, neutral and alkaline side. But the highest peak was at pH 9.5. Protease of all tested fungi was more active at pH 10.0, especially that of the cultural filtrate of H. sigmoideum var. irregualre.

  • PDF

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

Studies on effect and Safety of various Aqua-acupunctures from Scutellariae Radix (다양(多樣)한 황금약침제제(黃芩藥鍼製劑)의 안전성(安定性) 및 효능(效能)에 관한 연구(硏究))

  • Kim, Ho-Kyoung;Ma, Jin-Yeul;Cheon, Won-Kyung;Yun, Su-Young;Kang, Eun-Jung;Joo, Hye-Jeong;Ko, Byoung-Seob
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.183-197
    • /
    • 1997
  • In order to detect the safety and effect of various aqua-acupunctures from Scutellariae Radix, the modifications of boiling, filtration and dilution were employed for the manufacture of aqua-acupunctures. We injected 0.2cc of aqua-acupunctures into Joksamri (足三里) of rat, repeatedly. We compared subacute toxicity of them with saline group, distilled water(D.W.) group, acupuncture group and control group. The results were summarized as follows: 1. The groups were all healthy and alive, and there was no special abnormality in physical condition and autopsy. And there were not any toxic symptoms in repeating application of aqua-acupunctures to the rat, including changes of body weight, organ weight, haematological examination and serum biochemical test. 2. There was slight change of body weight in acupuncture group : We could see significance after 3 days(p<0.05) and after 7 days(p<0.001) in body weight loss. After 9 days, all tested groups were suppressed in body weight increment. 3. Result of organ weight : In Palkang aqua-acupuncture(D-2 group), saline group and acupuncture group there were some statistical significance. Especially, acupuncture group revealed significant result in liver and spleen than aqua-acupunctures. From this result, we could suggest that the efficacy of acupuncture was preceded herbal medicine. 4. In serum biochemical test, we examined glucose(GLU), triglyceride(TG) and cholesterol(CHOL). In comparison with control group, the diluted 10 times of Hwanggum aqua-aqupuncture$({\times}10\;group)$ was recognized significant decrease of glucose, but the diluted 100 times of Hwanggum aqua-acupuncture$({\times}100\;group)$, D-2 group, saline group were confirmed significant increment. There was not any meaningful change of CHOL in all of tested group, excepting the acupuncture group was exhibited statistically significant decrease(p<0.05). In TG level all tested group except complex injection of standard compound(CPA group) and HG, there were significant value iii statistically. The diluted solution was more significant decrease than Hwanggum aqua-acupuncture(HG). The mutual relationship of components of aqua-acupunture tended to decrease level of TG, regardless of its concentration. In acupunture guoup, we gained some interesting result In meaningful decrease in 7G. 5. Haematological examination showed significant increment of granulocytes(GR) in all tested groups except Hwanggum aqua-acupuncture. And the diluted solutions of HG expressed very high increment of them(p<0.001). The GR and Mean Corpuscular Volume(MCV) of acupuncture group showed statistical significance.

  • PDF

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.

Facile [11C]PIB Synthesis Using an On-cartridge Methylation and Purification Showed Higher Specific Activity than Conventional Method Using Loop and High Performance Liquid Chromatography Purification (Loop와 HPLC Purification 방법보다 더 높은 비방사능을 보여주는 카트리지 Methylation과 Purification을 이용한 손쉬운 [ 11C]PIB 합성)

  • Lee, Yong-Seok;Cho, Yong-Hyun;Lee, Hong-Jae;Lee, Yun-Sang;Jeong, Jae Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.67-73
    • /
    • 2018
  • $[^{11}C]PIB$ synthesis has been performed by a loop-methylation and HPLC purification in our lab. However, this method is time-consuming and requires complicated systems. Thus, we developed an on-cartridge method which simplified the synthetic procedure and reduced time greatly by removing HPLC purification step. We compared 6 different cartridges and evaluated the $[^{11}C]PIB$ production yields and specific activities. $[^{11}C]MeOTf$ was synthesized by using TRACERlab FXC Pro and was transferred into the cartridge by blowing with helium gas for 3 min. To remove byproducts and impurities, cartridges were washed out by 20 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ solution (pH 5.1) and 10 mL of distilled water. And then, $[^{11}C]PIB$ was eluted by 5 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ into the collecting vial containing 10 mL saline. Among the 6 cartridges, only tC18 environmental cartridge could remove impurities and byproducts from $[^{11}C]PIB$ completely and showed higher specific activity than traditional HPLC purification method. This method took only 8 ~ 9 min from methylation to formulation. For the tC18 environmental cartridge and conventional HPLC loop methods, the radiochemical yields were $12.3{\pm}2.2%$ and $13.9{\pm}4.4%$, respectively, and the molar activities were $420.6{\pm}20.4GBq/{\mu}mol$ (n=3) and $78.7{\pm}39.7GBq/{\mu}mol$ (n=41), respectively. We successfully developed a facile on-cartridge methylation method for $[^{11}C]PIB$ synthesis which enabled the procedure more simple and rapid, and showed higher molar radio-activity than HPLC purification method.