• Title/Summary/Keyword: distance university

Search Result 13,849, Processing Time 0.045 seconds

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

A Study on Morphology and Size of Clinical Crown of Permanent Maxillary Molar in Korean Adult (한국 성인의 상악 대구치 임상치관의 형태와 크기에 관한 연구)

  • Cha, Kwon-Sil;Oh, Sang-Chun;Dong, Jin-Keum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.79-92
    • /
    • 2000
  • The purpose of this study was to estimate the morphology and the size of permanent maxillary molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study. The subjects were taken impression to make study model. On the study model, authour three times measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. In the maxilary first molar's clinical crown height, mesiolingual cusp height was 6.34mm, mesiobuccal cusp height was 6.05mm, distobuccal cusp height was 5.20mm. And in the maxillary second molar's clinical crown height, mesiobuccal cusp height was 5.85mm, mesiolingual cusp height was 5.71mm, distobuccal cusp height was 5.51mm, distolingual cusp height was 3.53mm. This result considered that the maxillary first molar inclined to distobuccal, and the maxillary second molar more upright than the maxillary first molar. 2. In the width of clinical crown, the maxillary first molar was 10.43mm, the maxillary second molar was 10.20mm, and the difference between the first molar's width and the second molar's width was 0.23mm. 3. The crown thickness was measured divided into mesial buccolingual half and distal buccolingual half. The mesial buccolingual half was 11.14mm, and distal buccolingual half was 10.35mm in the maxillary first molar, and in the maxilary second molar, mesial buccolingual half was 11.25mm, and distal buccolingual half was 9.72mm. This result considered that height of convergency located in mesial half of crown. 4. In the buccal groove length, total length and ratio, the maxillary first molar was 52.5%, the maxillary second molar was 50%. And the development of buccal groove in the maxillary first molar was 59% in case of the well developed buccal groove and 41% in case of the weak developed one. And frequency of buccal pit of the maxillary first molar was 12.5%. Whereas, the frequency of buccal of the well developed buccal groove in the maxillary second molar was 37% and that of the weak developed one was 63%. And frequency of buccal pit of the maxillary second molar was not seen. 5. The 3 cusp type tooth cannot be found in the maxillary first molar and the frequency of 3 cusp type tooth in the maxillary second molar was as small as 6% 6. In the case of 4 cusp type tooth, the size of distal lingual cusp molar was difference between in the maxillary first molar and in the maxillary second molar by about 1mm. 7. The intercuspal distance was similar in the maxillary first premolar and second molar. And intercuspal distanc of mesial half of the maxillary first molar and the maxillary second molar was silmillar, too. 8. The an measurement of occlusal surface in 4 cusp type tooth showed that the angle of occlusal surface between the distobuccal and mesiolingual was an obtuse angle, and the angle of occlusal surface between mesiobuccal and distolingual was an acute angle in the both cases of maxillary first and second molar. 9. The measurements of the development of Carabelli cusp showed that the frequency of the well developed one was 7% and that of the weak developed one was 56% in the maxillary first molar. And there cannot be found the well developed one and can be found 2.5% only in the case of the weak developed one in the maxillary second molar. 10. The well developed oblique ridge in the maxillary first molar showed the 100% frequency and that in the maxillary second molar showed the 85.5% frequency. The frequency of mesiomarginal ridge tubercle in the maxillary first molar was 82% and that in the maxillary second molar was 30.5%. And the frequency of distal accessory tubercle in the maxillary first molar can be seen about 19% and that in the maxillary second molar can be seen about 12%.

  • PDF

Computerized Multiple 15-hue tests for Quantifying Color Vision Acuity (색각 능력의 정량적 평가를 위한 전산화된 다중 15-색상 배열 검사법)

  • Ko S.T.;Hong S.C.;Choi M.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.321-331
    • /
    • 2000
  • Multiple 15-hue tests were designed and implemented on a PC in the study so as to quickly and quantitatively evaluate color vision acuity. Difficulty of the test was control)ed by the value of CDBACC (color difference between adjacent color chips) calculated using a CIELAB formula. The multiple 15-hue tests consist of eight of the hue tests (test 3-10) and three of the basic color (red, green, blue) tests (test 11-13). The 15 colors used for the hue tests were specified by the 15 color coordinates that were located at a constant distance (d = 2. 3. 5. 7, 10, 20, 30. 40) from white reference in the CIE chromaticity coordinate system and were separated by a constant color difference (CDBACC = 0.75, 1.1, 1.8. 2.5. 3.5. 7.5. 11, 14) from the adjacent chips. The color coordinates for the 15 chips for the basic color tests were the same as those of the 15 points spaced equally by a constant color difference (6.87 for the green color test. 7.27 for the red color test, 7.86 for the blue color test) from the white reference along the axis of red, green and blue. Thirty normal subjects who were not color blind were taken to undergo the multiple 15-hue tests. It was observed that most of the subjects correctly arranged color chips for the tests with CDBACC greater than 5, whereas no one correctly answered for those with CDBACC less than 2. Rapid changes in the number of the subjects correctly arranged took place when CDBACC of the tests was between 2 and 4.5. In the basic color tests, unlike the hue tests having similar values of CDBACC, it was seen that the subjects arranged color chips even less correctly. It was found that JNCD (just noticeable color difference) - a measure of color vision acuity was about 3 in average for the subjects. The JNCD was chosen as the value of the CDBACC of the test for which about $50\%$ of the subjects failed to successfully arrange color chips. ERCCA (error rate of color chips arrangement) for the test with CDBACC the same as the JNCD was shown to be about $20\%$. It is expected that the multi 15-hue tests implemented on a PC in the study will be an economical tool to quickly and quantitatively evaluate color vision acuity and, accordingly, the tests can be used for early diagnosis to massive potential patients suffering from diseases (ex. diabetes, glaucoma) which may induce changes in color vision acuity.

  • PDF

Research on the Prototype Landscape of Former Donam SeoWon Located in YeonSan (연산 돈암서원(豚巖書院) 구지(舊址)의 원형경관 탐색)

  • Rho, Jae-Hyun;Choi, Jong-Hee;Shin, Sang-Sup;Lee, Won-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.14-22
    • /
    • 2012
  • The position, size and landscape of the former Donam SeoWon as well as the physical organization of the old site, are studied to extract data for the enhancement of the authenticity of Donam SeoWon since its registration as a world heritage site. The results are as follows. The 'Donam(豚巖)' encaved rock, the tombstone of teacher Sagye(沙溪), Kimjipsadang(金集祠堂), the head of the Gwangsan Kim family, the Sagye stream in front of them, and the Gyeryong and Daedun mountains in the distance are united in the former Donam SeoWon as landscape elements that clearly show the characteristics of the former site, which was called 'Donam-Wollim(豚巖園林).' Moreover Yangseongdangsipyoung(養性堂十詠), adds the garden elements of a medical herb field, twins pond, a bamboo forest, a school, and a peach field. On this site, one can also engage in activities that are related to the land and are closely related to Neo-Confucianism such as fish watching, conferencing, visit in seclusion(訪隱), looking for monks, and overseeing farming. The former site facing east is assumed to have Sau(祠宇) - Eungdodang(凝道堂) - Ipdeokmum(入德門) - Sanangru(山仰樓: estimated). Jeonsacheong seems to have been located to the left of the Sau area, Yangseongdang, which contained upper and lower twin lotus ponds, on the right and was surrounded by various plants. As it has been used as a lecture hall for the past 250 years, the former Donam SeoWon, located 1.8km away from the current area, must be preserved, and the landscape should be formed to establish the authenticity of Donam SeoWon.

A Study on the Visual Characteristics of the Landscape of Darangyi-paddy in Garchon, Namhae (남해 가천마을 다랑이논 경관의 시각적 특성에 관한 연구)

  • Youn, Kyung-Sook;Lee, Chang-Hun;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.76-84
    • /
    • 2010
  • Darangyi paddy in Namhae Gachon village provides natural beauty with its distinct location. Darangyi is a traditional Korean landscape, shaping a circular form to serve continuous cultivation. Despite the paddy's landscape, it is difficult to preserve its natural scenery due to many factors such as inadequate visual analysis. Under the belief that there is a necessity to preserve Darangyi paddy, the research in visual features of the paddy began to illustrate the relevance between its viewpoint and landscape objects. First, we researched typical view structures. When considering the visual features, Darangyi paddy landscape objects has a viewpoint from the horizontality to its below, which its center area is about $-5^{\circ}{\sim}-30^{\circ}$. From the analyzed data, the scenary of Darangyi paddy, which most people agree its decency, is formed in a visually decent location. The above type of measure of visual structure in Darangyi paddy is expected to be applied in maintenance of foothold of views in the future. Second, the surrounding elements play important parts to form the whole landscape of Gachon Darangyi paddy. Although Darangyi paddy is the principal part of the scenary, the landscape analysis showed a high relevance with the paddy's identity, forest around the paddy, sky, ocean, settlements, and the roads in terms of visual perception. It was affirmed that those elements around the paddy play important parts in structuring and providing the beauty of the whole landscape. Various viewy objects are seen obvious especially in a long distance, and the splendid scenary proved that those viewy objects are in indispensable location. In order to preserve the paddy, it seems necessary to consider the surrounding envrionment of Darangyi paddy, not just the paddy's sole landscape form. Third, Darangyi paddy has a distinct seasonal characteristics. According to the survey analysis, the full heading time in spring and time when people can take a picture against the sun light proved magnificence of Darangyi paddy. Thus, it would be ideal to maintain Darangyi paddy by securing the sunlight condition with decent landscape view and the views from its surrounding environments or researching the ways to principally maintain the surrounding environments.

Clinical Result of Arthroscopic Partial Repairs in Massive Rotator Cuff Tears (광범위 회전근 개 파열의 관절경하 부분 봉합술의 임상적 결과)

  • Yoo, Jae-Chul;Ko, Kyung-Hwan;Woo, Kyung-Jea
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.150-158
    • /
    • 2009
  • Purpose: With the better understanding of cuff function, partial repair or "force couple repair" for treating massive irreparable rotator cuff tear has gained some popularity. However, there were few reports on the results of partial repair. The purpose of this study was to report the clinical outcome of massive irreparable rotator cuff tears who received arthroscopic force-couple repair or partial repair. Materials and Methods: From June 2005 to Feb 2008, arthroscopic partial repairs were performed for 16 irreparable rotator cuff tears among the 101 large to massive rotator cuff tears that were operated on. Clinical and radiographic evaluation were done at the final follow-up. Results: There were 7 men and 9 women with a mean age of 66.6 years. The mean follow-up period was 27.3 month (range: 15-46). The pain VAS improved from 4.4 ($\pm2.50$) to 2.1 ($\pm2.26$) and the functional VAS improved from 46.9 ($\pm16.64$) to 70.0 ($\pm22.80$). The ASES score improved from 39.0 ($\pm10.80$) to 80.3 ($\pm16.78$) and the KSS score was 81.9 ($\pm16.74$) at the final follow-up. The acromio-humeral distance was 6.6 cm ($\pm1.74$) preoperatively and 6.2 cm ($\pm1.69$) postoperatively without significant change (p=0.3874). The degenerative changes had no statistically progressed (p=0.2663). Conclusion: Partial repair for massive rotator cuff injury patients showed improvement in the clinical score without progression of arthritic change at a mean of 2.3 years follow-up.

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

An Oceanic Current Map of the East Sea for Science Textbooks Based on Scientific Knowledge Acquired from Oceanic Measurements (해양관측을 통해 획득된 과학적 지식에 기반한 과학교과서 동해 해류도)

  • Park, Kyung-Ae;Park, Ji-Eun;Choi, Byoung-Ju;Byun, Do-Seong;Lee, Eun-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.234-265
    • /
    • 2013
  • Oceanic current maps in the secondary school science and earth science textbooks have played an important role in piquing students's inquisitiveness and interests in the ocean. Such maps can provide students with important opportunities to learn about oceanic currents relevant to abrupt climate change and global energy balance issues. Nevertheless, serious and diverse errors in these secondary school oceanic current maps have been discovered upon comparison with up-to-date scientific knowledge concerning oceanic currents. This study presents the fundamental methods and strategies for constructing such maps error-free, through the unification of the diverse current maps currently in the textbooks. In order to do so, we analyzed the maps found in 27 different textbooks and compared them with other up-to-date maps found in scientific journals, and developed a mapping technique for extracting digitalized quantitative information on warm and cold currents in the East Sea. We devised analysis items for the current visualization in relation to the branching features of the Tsushima Warm Current (TWC) in the Korea Strait. These analysis items include: its nearshore and offshore branches, the northern limit and distance from the coast of the East Korea Warm Current, outflow features of the TWC near the Tsugaru and Soya Straits and their returning currents, and flow patterns of the Liman Cold Current and the North Korea Cold Current. The first draft of the current map was constructed based upon the scientific knowledge and input of oceanographers based on oceanic in-situ measurements, and was corrected with the help of a questionnaire survey to the members of an oceanographic society. In addition, diverse comments have been collected from a special session of the 2013 spring meeting of the Korean Oceanographic Society to assist in the construction of an accurate current map of the East Sea which has been corrected repeatedly through in-depth discussions with oceanographers. Finally, we have obtained constructive comments and evaluations of the interim version of the current map from several well-known ocean current experts and incorporated their input to complete the map's final version. To avoid errors in the production of oceanic current maps in future textbooks, we provide the geolocation information (latitude and longitude) of the currents by digitalizing the map. This study is expected to be the first step towards the completion of an oceanographic current map suitable for secondary school textbooks, and to encourage oceanographers to take more interest in oceanic education.

A Field Survey on Concentration of Odor Compounds in Pig Buildings and Boundary Areas (돈사 내 및 부지경계에서 악취물질 발생 조사 연구)

  • Yoo Yong-Hee;Kim Tae-Il;Jeong Jong-Won;Gwak Jeong-Hun;Choi Hee-Chul;Song Jun-Ik;Yang Chang Bum;Jang Young-Kee;Kim Ho-Jung;Song Ki-Pong
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • A field survey was conducted to determine the concentration of odor compounds from pig buildings and that were 20 meters within the boundary area. The odor compounds were measured from large, medium and small farms with enclosed and open housing systems and slurry and sawdust manure fermentation treatment methods. Among the odor compounds investigated, ammonia ($NH_3$) had the highest concentration at 0.9 ${\~}$ 21.0 ppm followed by Hydrogen Sulfide($H_2S$) with a wide variation concentration of 51.9 ${\~}$ 6,712.4 pub, Uethylmercaptan($CH_3SH$) with non-detectable (N. D.) ${\~}$ 12.9 ppb, Dimethylsulphide($(CH_3)_2S$), with N. D. ${\~}$ 5.2 ppb and Dimethyldisulphide($(CH_3)_2S_2$) with N. D. ${\~}$ 2.6 ppb. Considering the prevailing wind direction and air velocity ranging from 0.23 to 0.73 m/s within the boundary area, the odorous matters; $NH_3$, $H_2S$, $CH_3SH$, $(CH_3)_2S_2$ and $(CH_3)_2S$ were 0.2${\~}$4.5 ppm, 0.01 ${\~}$0.06 ppb, N. D. ${\~}$0.009ppb, N. D.${\~}$0.002ppb and N. D. for $(CH_3)_2S$ respectively. These findings suggested that the Odor compounds $(CH_3)_2S_2$ had the lower detection in the boundary area whilst $(CH_3)_2S$ had no detection level within a 20-meter distance only. However, with these results odor compounds from pig buildings has to be further investigated under more controlled environmental factors.

  • PDF