• 제목/요약/키워드: distance transform

검색결과 435건 처리시간 0.021초

파장 주사 간섭계를 이용한 불연속면의 표면 형상 측정 알고리즘 (An Algorithm for Discontinuous Surface Profile Measurement using Wavelength Scanning Interferometer)

  • 우현구;강철무;조형석
    • 제어로봇시스템학회논문지
    • /
    • 제9권7호
    • /
    • pp.507-514
    • /
    • 2003
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. Recently the shape measurement using interferometric principle is found to be a successful methodology among other visual or optical technologies. Especially, the measuring method using wavelength scanning interferometer(WSI) has a great advantage in comparison with other conventional jnterferometric methods in that the absolute distance from the reference surface can be directly obtained from the amount of jnterferometric phase change. However, the measurement methods using WSI proposed by other researchers have low measurement resolution so far because they can't measure fractional phase change. To avoid this shortcoming we propose a new algorithm in this paper, which can obtain a small amount of even fractional phase change by sinusoidal function fitting. To evaluate the effectiveness of the proposed sinusoidal function fitting algorithm, a series of measuring experiments are conducted for discontinuously shaped specimens which have various height. The proposed algorithm shows much more enhanced measurement resolution than other existing conventional algorithms such as zero crossing algorithm and Fourier transform algorithm.

신호처리 기법을 응용한 차량번호판 추출방법 (A Method to Extract Vehicle Number Plates by Applying Signal Processing Techniques)

  • 전병태;윤호섭
    • 전자공학회논문지B
    • /
    • 제30B권7호
    • /
    • pp.92-101
    • /
    • 1993
  • This paper describes algorithms to extract license plates in vehicle images. Conventional methods perform preprocessing on the entire vehicle image to produce the edge image and binarize it. Hough transform is applied to the binary image to find horizontal and vertical lines, and the license plate area is extracted using the charateristics of license plates (the boundary information of license plates). Problems with this approach are that real-time processing is not feasible due to long processing time and that the license plate area is not extracted when lighting is irregular such as at night or when the plate boundary does not show up in the image. This research uses the gray level transition characteristics of license plates to verify the digit area by examining the digit width and the gray level difference between the background area the digit area, and then extracts the plate area by testing the distance between the verified digits. This research solves the probelm of failure in extracting the license plates due to degraded plate boundary as in the conventional methods and resolves the provlem of the time requirement by processing in real time such that practical application is possible.

  • PDF

소프트카피 사진측량에 의한 사면지반 측정 (A Study on the Measurement of Slope by Softcopy Photogrammetry)

  • 배상호;이형석;주영은
    • 한국측량학회지
    • /
    • 제19권2호
    • /
    • pp.183-188
    • /
    • 2001
  • 사면 슬라이딩에 따른 추가 세부 공사 계획의 수행에 중요하게 사용되는 데이터는 지형도이다. 이는 사면 슬라이딩이 발생한 지역의 토공량 산정과 공사비 산출, 그리고 안전성 검토에 사용되는 기본도인 것이다. 따라서, 본 연구에서는 사면 슬라이딩이 발생한 위험사면에 대해 소프트카피 사진측량을 적용하여 3차원 지형데이터를 획득하고, 이를 기존 TM 좌표의 지형도와 동일한 좌표 체계로 변환하는 방안을 구축하였다. 300 m 전방에서 촬영한 영상을 분석하여 1m등고선을 생성하는데 발생되는 문제점을 해결하여 도로 확장 공사의 터널 진입구간 계획에 중요한 데이터로 사용할 수 있었으므로, 토목 분야의 다양한 위험 지역의 측정에 그 효용성이 높은 것으로 사료된다.

  • PDF

전력 역변환장치 주요발열부의 열 저감 시스템 변위에 따른 냉각 특성해석 (Analysis of Cooling Characteristics according to Heating Reduction System Displacement of Major Heating Region on Power Inverter)

  • 김민석;김용재
    • 한국전자통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.261-266
    • /
    • 2015
  • 신재생에너지용 발전 시스템은 모듈, 직류 전력을 교류 전력으로 변환시키는 전력 역변환장치, 전력흐름을 제어하고 계통 연계를 담당하는 제어장치로 구성된다. 이러한 시스템은 일사량이 많은 여름철 및 낮 시간에 가장 많은 직류전력을 생산하지만 계통의 연계를 위해 필수적인 전력 역변환장치는 특정 온도 이상으로 상승하면 효율이 급격히 감소하게 된다. 따라서 열전소자를 부착한 열 저감 시스템을 제안하고 가장 발열이 심한 구간을 선정하여 사용개수 및 위치에 따른 온도 특성 해석을 통해 최적 모델을 도출하고자 한다.

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

합성 데크 플레이트 바닥구조의 단면환산 단순화를 통한 고유진동수 예측식의 보정에 관한 연구 (A Study on Adjustment of Prediction Equation for Natural Frequency Using the Simplification of Section Transformation Method of Composite Deck Plate Floor Systems)

  • 임지훈;김희철;홍원기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.731-738
    • /
    • 2001
  • The conventional techniques for the prediction of natural frequency are often used to estimate the floor vibration. However. the predicted frequency differs significantly from the measured one since the predicted equation is not able to proper1y treat various material type. Transformation of slab section is necessary to predict natural frequency of composite deck plate, and this effort is complicated due to the various shape of each deck plate. In this study, a new simplified methodology to transform slab section is proposed, which treats effective depth as the distance from the top of a concrete topping to neutral axis of each deck plate. Finally proposed equation with fairly reasonable result compared to the measured values is obtained. based on the modification of vibration equation from LRFD theory. This efforts enhance errors in predicting frequency up to 15%.

  • PDF

Three-dimensional dynamics of the moving load acting on the interior of the hollow cylinder surrounded by the elastic medium

  • Akbarov, S.D.;Mehdiyev, M.A.;Ozisik, M.
    • Structural Engineering and Mechanics
    • /
    • 제67권2호
    • /
    • pp.185-206
    • /
    • 2018
  • This paper studies the non-axisymmetric 3D problem on the dynamics of the moving load acting in the interior of the hollow cylinder surrounded with elastic medium and this study is made by utilizing the exact equations of elastodynamics. It is assumed that in the interior of the cylinder the point located with respect to the cylinder axis moving forces act and the distribution of these forces is non-axisymmetric and is located within a certain central angle. The solution to the problem is based on employing the moving coordinate method, on the Fourier transform with respect to the spatial coordinate indicated by the distance of the point on the cylinder axis from the point at which the moving load acts, and on the Fourier series presentation of the Fourier transforms of the sought values. Numerical results on the critical moving velocity and on the distribution of the interface normal and shear stresses are presented and discussed. In particular, it is established that the non-axisymmetricity of the moving load can decrease significantly the values of the critical velocity.

Examination of analytical and finite element solutions regarding contact of a functionally graded layer

  • Yaylaci, Murat;Adiyaman, Gokhan;Oner, Erdal;Birinci, Ahmet
    • Structural Engineering and Mechanics
    • /
    • 제76권3호
    • /
    • pp.325-336
    • /
    • 2020
  • In this study, the continuous and discontinuous contact problems of functionally graded (FG) layer resting on a rigid foundation were considered. The top of the FG layer was loaded by a distributed load. It was assumed that the shear modulus and the density of the layer varied according to exponential functions along the depth whereas the the Poisson ratio remained constant. The problem first was solved analytically and the results were verified with the ones obtained from finite element (FE) solution. In analytical solution, the stress and displacement components for FG layer were obtained by the help of Fourier integral transform. Critical load expression and integral equation for continuous and discontinuous contact, respectively, using corresponding boundary conditions in each case. The finite element solution of the problem was carried out using ANSYS software program. In continuous contact case, initial separation distance and contact stresses along the contact surface between the FG layer and the rigid foundation were examined. Separation distances and contact stresses were obtained in case of discontinuous contact. The effect of material properties and loading were investigated using both analytical and FE solutions. It was shown that obtained results were compatible with each other.

Impact location on a stiffened composite panel using improved linear array

  • Zhong, Yongteng;Xiang, Jiawei
    • Smart Structures and Systems
    • /
    • 제24권2호
    • /
    • pp.173-182
    • /
    • 2019
  • Due to the degradation of beamforming properties at angles close to $0^{\circ}$ to $180^{\circ}$, linear array does not have a complete $180^{\circ}$ inspection range but a smaller one. This paper develops a improved sensor array with two additional sensors above and below the linear sensor array, and presents time difference and two dimensional multiple signal classification (2D-MUSIC) based impact localization for omni-directional localization on composite structures. Firstly, the arrival times of impact signal observed by two additional sensors are determined using the wavelet transform and compared, and the direction range of impact source can be decided in general, $0^{\circ}$ to $180^{\circ}$ or $180^{\circ}$ to $360^{\circ}$. And then, 2D-MUSIC based spatial spectrum formula using uniform linear array is applied for locate accurate position of impact source. When the arrival time of impact signal observed by two additional sensors is equal, the direction of impact source can be located at $0^{\circ}$ or $180^{\circ}$ by comparing the first and last sensor of linear array. And then the distance is estimated by time difference algorithm. To verify the proposed approach, it is applied to a quasi-isotropic epoxy laminate plate and a stiffened composite panel. The results are in good agreement with the actual impact occurring position.

Design Considerations of Cryogenic Cooling System for High Field Magnets

  • Choi, Yeon-Suk;Kim, Dong-Lak;Lee, Byoung-Seob;Yang, Hyung-Suk;Yoo Jong-Shin;Painter Thomas A.;Miller John R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권4호
    • /
    • pp.30-33
    • /
    • 2006
  • Several crucial issues are discussed in the design of cryogenic cooling system for high field magnets. This study is mainly motivated by our ongoing program to develop a 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The magnets of this system will be built horizontally to accomplish the requirement of user friendliness and reliability, and the replenishment of cryogen will not be necessary by a closed-loop cooling concept. The initial cool-down and safety are basically considered in this paper. The effects of the helium II volume and the gap distance of the weight load relief valve (or safety valve) on the cool-down time and temperature rising during an off-normal state are discussed. The total amount of cryogenic cooling loads and the required helium flow rate during cool-down are also estimated by a relevant heat transfer analysis. The temperatures of cryogen-free radiation shield are finally determined from the refrigeration power of a cryocooler and the total cryogenic loads.