• Title/Summary/Keyword: distance measurement error

Search Result 395, Processing Time 0.028 seconds

IMRT and IMRS Checking the Dose Distribution in the Small Field Evaluation of Measurement by Changes in SAD (IMRT 및 IMRS에서 Small Field의 선량분포 확인시 SAD 변화에 따른 측정의 유용성 평가)

  • Ko, Seung-Young;Kim, Sung-Joon;Park, Gir-Yong;Son, Mi-Suk;Lee, Nam-Ki;Kim, Jin-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • Purpose: It is very important to confirm conformance of dose distribution that is formed with treatment planning from IMRS or IMRT. It has been a problem dropped accuracy and conformance when the field size is getting smaller because of character of the 2D ion chamber. Verification of MatriXX Phantom dose distribution with a change in the SAD. Dose distribution measurement and analysis to improve the accuracy and should be useful to evaluate the award. Materials and Methods: A use of Novalis linear accelerator 6 MV photon beams. In general, IMRS were 25 patients with small field size. The selected patients were divided into three groups on the basis of the field size. SAD was changed from 80 to 130 cm and field size to determine the dose distribution to the change, each dose was measured using MatriXX Phantom. Analysis of measured values obtained from the program for each patient through the treatment planning system comparison and analysis of the dose distribution and gamma values were expressed. Result: SAD 80, 100, and 120 cm in size in the gamma value to the investigation of patients less than $3\;cm^2$ average 0.939, 0.969, and 0.979, respectively. Patients with more than $5\;cm^2$ 0.962, 0.983, and 0.988, respectively. $5\;cm^2$ or more patients 0.982, 0.990, and 0.992, respectively. Conclusion: The error rate of less than $3\;cm^2$ field size is increased rapidly. If the field size is increased, resolution is increased by 2D ion chambers. It has been approved that it can be credible if it is around $3\;cm^2$ when measuring dose distribution using MatriXX. Adjusting geometric field size by changing SAD is likely to be very useful when you measure dose distribution using MatriXX.

  • PDF

The availability for cardiorespiratory fitness measurement by 20 m shuttle run test in different sports type of elite athletes. Exercise Science (엘리트 선수들의 운동특성에 따른 20 m 셔틀런 검사의 유용성)

  • Kim, J.K.;Lee, N.J.;Lee, M.S.
    • Exercise Science
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • This study is to evaluate the availability of cardiorespiratory fitness measurement by 20 m shuttle run test based upon energy contribution rates of elite athletes in different sports type. Sixty-seven elite athletes attending K national university participated in this study. They were divided by three groups based upon sports type, composed of Anaerobic Group (sprint, jumps, weightlifting, throw; n=35), Aerobic Group (medium-long distance; n=9), and Combat Sport Group (judo; n=23). 20 m shuttle run test was conducted by Leger et al.(1982) method and calculating acceleration using measured shuttle run repetitions was conducted by Brewer et al.(1988) method. To test the usefulness of VO2max, graded exercise treadmill test was conducted and standing long jump and 50 m run were measured as power fitness factors. Z-jump was used for measuring power, agility, and muscular endurance. Standing long jump and 50 m run of Anaerobic Group (AnG) was significantly higher than that of Aerobic Group (AeG) and Combat Sport Group (CG) (p<0.05). However, Z-jump of CG was significantly higher than that of AnG and AeG(p<.05). There was a higher correlation of 20 m shuttle run test and VO2max in AnG(r= 0.577, p<.0001) and CG(r= 0.760, p<.0001). Otherwise, there was a low correlation of 20 m shuttle run test and VO2max in AeG. There was no significant group difference to test the availability of 20 m shuttle run test and there was a reduced error when converting 20 m shuttle run results into VO2max. This study examined the usefulness of 20 m shuttle run test by converting 20 m shuttle run repetition results into VO2max calculation, which showed reduced error. Therefore, this study confirmed that it would be needed to convert 20 m shuttle run results into VO2max for universal and practical use in the field without dividing sports type.

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

A Study on Tension for Cables of a Cable-stayed Bridge Damper is Attached (댐퍼가 부착된 사장교의 케이블 장력에 관한연구)

  • Park, Yeon Soo;Choi, Sun Min;Yang, Won Yeol;Hong, Hye Jin;Kim, Woon Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 2008
  • Recently, many ocean bridges that connect land to island or island to island have been constructed along with the improvement of the nation's economy. Long-span bridges can be categorized as suspension bridge, cable-stayed bridge, arch bridge and truss bridge. In this study, correction with respect to construction error can be presented on site through the monitoring of the cable tension change of real structure for four major construction stages so that construction accuracy, including the management of profiles, can be improved. A vibration method, the so-called indirect method that uses the cable's natural frequency changes from the acceleration sensor installed on the cable, is applied in measuring cable tension. In this study, the estimation formula for the effective length of cable with damper is presented by comparing and analyzing between actual measurement and analysis result for the change of the cable's effective length. By the way, it is known that the reliability of estimating cable tension by applying the former method that uses the net distance from damper to anchorage is low. Therefore, for future reference of the maintenance stage, the presented formula for estimating the effective length of cable can be used as a reference for the rational decision-making, such as the re-tensioning and replacement of cable.

A Technology of Microwave Direction Finding with Circular Array Combination Method (원형 배열 복합 방식을 이용한 초고주파 방향 탐지 기술)

  • Lim Joong-Soo;Jung Chul-Gu;Chae Gyoo-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.549-555
    • /
    • 2005
  • This paper describes a microwave direction finding technology which is used for RF signal acquisition and monitoring systems. This paper suggests a direction finding method which use a combination of the amplitude-comparison technology and the phase-comparison technology. The amplitude-comparison technology uses the amplitude difference of the RF signals received from the array antennas of direction finding system and removes the ambiguity of wave incident bearing. The phase-comparison technology uses the phase difference of the RF signals received from the same nay antennas and makes a good direction finding accuracy. The suggested direction finding technology is designed to place 8 array antennas in a $45^{\circ}$ distance around the circle for $360^{\circ}$ azimuth angle. Also it is designed to use the phase difference of the received signals ken two nearby antennas to measure the signal incident direction accurately and to use the amplitude difference to remove the ambiguity of wave incident bearing. The simulation and measurement results are under $0.5^{\circ}$ bearing error in $2.0\~6.0$ GHz when SNR is 30 dB.

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (1) - Design and production of system - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (1) -시스템의 설계 및 제작 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.218-229
    • /
    • 2003
  • A new biotelemetry method that the installation and the treatment of equipment is convenient and the instantaneously detailed location of the fish attached the pinger is able to track comparatively easily was developed. The receiving system in this biotelemetry method was advanced for track the detailed behavior of the fish by the miniature tracking pinger, because it was a burden to fish to add the pinger with the water temperature and the pressure sensor. By combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger, the three dimensional locations of fish to the receiving transducer is gotten instantaneously. The receiving system is devised to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry developed by the present authors and the hydrophone array configuration. The measurement distance error in the pinger synchronizing method is minimized through the correction of which the deviation of transmission pluse period of pinger is caused by changing water temperature. A prototype system which is able to track the instantaneously detailed location of the fish by the SSBL and pinger synchronizing biotelemetry (SPB) method was produced.

Enhancement for Performance of Monopulse and Target Tracking for Communication Signal Tracking (통신신호 추적을 위한 모노펄스 및 추적성능 향상 방안)

  • Kil, Hyun Joo;Lee, Young Jin;Kim, Jae Sin;Lee, Eun Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.35-43
    • /
    • 2014
  • In this paper, we propose a performance enhancement method of the target tracking system for communication signal using the monopulse and the ${\alpha}{\beta}$ filter to keep the connection of the communication system between the airplane and the ground. We suggest the minimum distance measurement method for tracking error angle of the monopulse signal instead of the generally used method of MR(Monopulse Ratio) curve, and the ${\alpha}{\beta}$ filter with variable gain for enhancement of the tracking accuracy and the probability of re-tracking the monopulse signal under the disconnection of link. We show the performance enhancement of the proposed method of monopulse system using the measured MR Curve results of the prototype system. And also, the comparison of simulation results between the ${\alpha}{\beta}$ filter with variable gain and the ${\alpha}{\beta}$ filter with fixed gain shows the performance enhancement of the proposed ${\alpha}{\beta}$ filter. Using the proposed methods, we expect the enhanced performance of the existing target tracking system for communication signal only by changing the algorithm without hardware changes.

A study on the Traffic Density Collect System using View Synthesis and Data Analysis (영상정합을 이용한 교통밀도 수집방법과 수집 데이터 비교분석)

  • Park, Bumjin;Roh, Chang-gyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.77-87
    • /
    • 2018
  • Traffic Density is the most important of the three primary macroscopic traffic stream parameters, because it is most directly related to traffic demand(Traffic Engineering, 2004). It is defined as the number of existing vehicles within a given distance at a certain time. However, due to weather, road conditions, and cost issues, collecting density directly on the field is difficult. This makes studies of density less actively than those of traffic volume or velocity. For these reasons, there is insufficient attempts on divers collecting methods or researches on the accuracy of measured values. In this paper, we used the 'Density Measuring System' based on the synthesise technology of several camera images as a method to measure density. The collected density value by the 'Density Mesuring System' is selected as the true value based on the density define, and this value was compared with the density calculated by the traditional measurement methods. As a result of the comparison, the density value using the fundamental equation method is the closest to the true value as RMSE shows 1.8 to 2.5. In addition, we investigated some issues that can be overlooked easily such as the collecting interval to be considered on collecting density directly by calculating the moment density and the average density. Despite the actual traffic situation of the experiment site is LOS B, it is difficult to judge the real traffic situation because the moment density values per second are observed max 16.0 (veh/km) to min 2.0 (veh/km). However, the average density measured for 15 minutes at 30-second intervals was 8.3-7.9 (veh/km) and it indicates precisely LOS B.

An Experimental Study on Compensation Algorithm for Localization using Modified Bilateration Technique and Pyroelectric Sensor in a Ship (변형 이변측위기법과 초전센서를 이용한 선내 위치인식 보정 알고리즘에 관한 실험적 연구)

  • Seong, Ju-Hyeon;Choi, Jae-Hyuk;Kim, Jong-Su;Seo, Dong-Hoan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.488-495
    • /
    • 2012
  • The real-time indoor location technology using radio waves has been studied in a variety of environments. One of them, a ship which consists of steel structure has high reception rate but causes significant ranging error due to the reflection of radio waves. In order to reduce location measurement errors that occurs in such a environment, this paper, based on CSS of IEEE 802.15.4a, presents compensation algorithm for localization using modified bilateration and pyroelectric sensor in a ship. The proposed system reduces the number of fixed nodes by estimating the appropriate reception distance between mobile node and fixed node through the analysis of CSS characteristic in a narrow passage such as ship corridors. Also, in the corner section which the ranging errors are significantly fluctuated due to the reflection and diffraction of radio waves, we recognize the location by tracking the a moving section using modified bilateration technique and pyroelectric sensor. The experimental results show that the location accuracy and efficiency of the proposed algorithm are improved 86.2 % compared to general method.

A new method for determining OBS positions for crustal structure studies, using airgun shots and precise bathymetric data (지각구조 연구에서 에어건 발파와 정밀 수심 자료를 이용한 OBS 위치 결정의 새로운 방법)

  • Oshida, Atsushi;Kubota, Ryuji;Nishiyama, Eiichiro;Ando, Jun;Kasahara, Junzo;Nishizawa, Azusa;Kaneda, Kentaro
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2008
  • Ocean-bottom seismometer (OBS) positions are one of the key parameters in an OBS-airgun seismic survey for crustal structure study. To improve the quality of these parameters, we have developed a new method of determining OBS positions, using airgun shot data and bathymetric data in addition to available distance measurements by acoustic transponders. The traveltimes of direct water waves emitted by airgun shots and recorded by OBSs are used as important information for determining OBS locations, in cases where there are few acoustic transponder data (<3 sites). The new method consists of two steps. A global search is performed as the first step, to find nodes of the bathymetric grid that are the closest to explaining the observed direct water-wave traveltimes from airgun shots, and acoustic ranging using a transponder system. The use of precise 2D bathymetric data is most important if the bottom topography near the OBS is extremely rough. The locations of the nodes obtained by the first step are used as initial values for the second step, to avoid falling into local convergence minima. In the second step, a non-linear inverse method is executed. If the OBS internal clock shows large drift, a secondary correction for the OBS internal clock is obtained, as well as the OBS location, as final results by this method. We discuss the error and the influence of each measurement used in the determination of OBS location.