• Title/Summary/Keyword: distance P.D

Search Result 377, Processing Time 0.045 seconds

Blood Protein Polymorphisms of Native Fowls in Laos

  • Okamoto, S.;Tsunekawa, N.;Kawamoto, Y.;Worawut, R.;Kawabe, K.;Maeda, Y.;Nishida, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.7
    • /
    • pp.1011-1014
    • /
    • 1999
  • Blood protein polymorphism of fowls in Laos was analyzed by electrophoresis. Blood samples were collected in the area of Viangchan, Louangphrabang and Pakxe. Out of 17 loci, polymorphism was detected at the following seven loci; ES-1, Amy-1, Akp-akp, Akp-2, Alb, Tf and Pas. The other ten loci; Amy-3, LDH, 6-PGD, PGM, PHI, To, MDH, Es-D, Hb-l, Hb-2 were noted to be monomorphic. The proportion of polymorphic loci $(P_{poly})$, the expected average heterozygosity per individual ($\bar{H}$), and the subdivision index $(G_{ST})$ of the native fowl in Laos was $0.412{\pm}0.123$, 0.106 and 0.026, respectively. Genetic distance between native fowls in Laos, Bangladesh, and Nepal was clustered in one group.

Sensor-based Local Homing Algorithm using Fuzzy Theory (퍼지 이론을 사용한 Sensor-based Local Homing 알고리즘 개발)

  • Bang, S.W.;Lee, J.Y.;Kim, S.D.;Yoo, W.P.;Chung, M.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.387-390
    • /
    • 1993
  • The most important technique for an indoor robot navigation is to find out the direction and the distance from the current location to the destination through the information achieved from the sensor. For this purpose, we suggest sensor-based local homing method which compares the destination sensory data with the current location. As for the sensors, we use the CCD camera and the ultrasonic sensor, and recorded entire 360 degree panoramic data. We match the features of the image data, and the distance and the direction of the matched point will be considered as fuzzy numbers. Through a simple fuzzy arithmetic, we infer the geometric relations between the current location and the destination location.

  • PDF

An Experimental Study on the Recognition Region of Passive Soundscape Facilities Especially in Fountains (자연형 사운드스케이프 요소인 분수의 인지범위에 관한 실험적 연구)

  • Song, Min-Jeong;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.544-550
    • /
    • 2006
  • The interaction between people and sound and the way how people consciously perceive their environment are central approach to soundscape research. In this respect, this paper aims to clarify the relationship between water-sound level and recognition region in urban area. As a passive soundscape facility, fountain is a useful way to give place such as public square, park identity and vitality. In this study, to know the optimistic distance and sound level range from fountain, sound levels due to distance were measured and subject responses were checked by questionnaire. As a result, levels from 63 dB to 67 dB were recommended by subjects and moving forward to fountain less satisfactory than backward. Moving forward 5 m and backward 5 m(total range 10 m): there was a difference in satisfaction ratio by 2,5 out of 10. The results of this study could be used for street furniture location design and P.A. system output level.

A Group Pile Effect on Changing Size of Pile Cap in Group Pile under Sand Soil in Earthquake (지진 시 사질토 지반에 근입된 무리말뚝의 말뚝 캡 크기가 무리말뚝 효과에 미치는 영향)

  • Lee, Hyunkun;Ahn, Kwangkuk;Kang, Hongsig
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.10
    • /
    • pp.39-46
    • /
    • 2019
  • The interaction between the ground and structures should be considered for seismic design of group piles supporting the superstructure. The p-y curve has been used widely for the analysis of nonlinear relationship between the ground and structures, and various researches have conducted to apply the dynamic p-y curve for seismic design of group piles. This curve considers the interaction between the ground and structures under the dynamic load such as an earthquake. However the supported effect by the pile cap and the interaction by inertia behavior of superstructures. Therefore, the shaking table test was conducted to verify the effect of the change of the pile cap in group piles supporting superstructures embedded in sandy soil. The test condition is that the arrangement and distance between centers of piles are fixed and the length of the pile cap is changed for various distances between the pile cap side and the pile center. The result shows that the distance between the pile cap side and the pile center have an effect on the dynamic p-y curve and the effect of group piles.

IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT (팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구)

  • Kim, You-Hyun;Yeo, In-Hwan;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

Design of a Single-Balanced Diode Mixer of FMCW Radar for Vehicle Detection (차량 감지용 FMCW 레이더의 단일 평형 다이오드 주파수 혼합기 설계 및 제작)

  • 한석균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1335-1340
    • /
    • 2003
  • In this paper, a single balanced diode Mixer for the homodyne FMCW radar to detect distance and velocity of a vehicle target is designed and implemented using a microstrip line and two schottky barrier beam lead diodes. This mixer is optimally designed to have less a conversion loss within the 100 MHz bandwidth with a little LO injection power and a higher LO isolation as soon as possible through the embedded electrical length of microsrtrip line placed between the coupler and diode matching, considering together LO matching condition. The measured results show 6 dB of conversion loss, 23 dB LO/RF isolation and 3 dBm of input 1l dB, respectively.

Heat Transfer Enhancement by the Perforated Plate of Round Impinging Air Jets (원형충돌제트에서 다공질판에 의한 열전달 향상)

  • Kim, Yun-Taek;Lee, Yeong-Min;Won, Se-Yeol;Lee, Dae-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.475-484
    • /
    • 2001
  • The purpose of this study is to investigate the heat transfer augmentation using the perforated plate placed in front of a target plate in an axisymmetric impinging air jet system. The new liquid crystal technique using neural networks with median filtering is used to determine the Nusselt number distributions on the target surface. The experiments were made for the jet Reynolds number (Re) 23,000. The effects of the pitch-to-diameter (p/d1) from 1.5 to 2.5 in the perforated plate, the hole diameter on perforated plate (d1) from 4㎜ to 12㎜, the perforated plate to target surface distance (z/d1) from 1 to 3, and the nozzle-to-target surface distance (L/d) from 2 to 10 on the heat transfer characteristics were experimentally investigated. It was found that when the perforated plate was located between the nozzle exit and the target plate, the average heat transfer rate at the stagnation region corresponding to r/d$\leq$1.0 was increased up to the maximum 2.3 times compared to the case without the perforated plate.

Spatial Relationship of the Left Ventricle in the Supine Position and the Left Lateral Tilt Position (Implication for Cardiopulmonary Resuscitation in Pregnant Patients) (앙와위와 좌측 기울린위치에서의 좌심실의 공간적 관계 변화. 임신부 심폐소생술 측면에서)

  • Yun, Jong Geun;Lee, Byung Kook
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.75-79
    • /
    • 2013
  • Application of the left lateral tilt position has been recommended during cardiopulmonary resuscitation (CPR) of pregnant patients. However, the left lateral tilt could displace the left ventricle (LV) besides the gravid uterus and may compromise the cardiac pump mechanism of CPR. Thus, we investigated the effect of left lateral tilt on the spatial relationship between the anterior-posterior axis (AP axis), which represents the direction of sternal displacement during CPR, and the LV. We retrospectively reviewed the medical records and multidetector computed tomography (MDCT) scans of 90 patients who underwent virtual gastroscopy using MDCT. Virtual gastroscopy was performed with the patient both in the left lateral tilt position and in the supine position. On an axial image showing the maximal area of the LV, the angle between the AP axis and the LV axis ($Angle_{AP-LV}$), the shortest distance between the AP axis and the mid-point of LV cavity ($D_{AP-MidLV}$) and the shortest distance between the AP axis and the LV apex ($D_{AP-Apex}$) were measured. In the supine scans, the LV was situated on the left side of the AP axis in 87 patients (96.7%). On the left lateral tilt scans, the mean tilt angle was $43.4{\pm}11.0^{\circ}$. $D_{AP-MidLV}$ and $D_{AP-Apex}$ were significantly longer in the left lateral tilt position (p<0.001), but $Angle_{AP-LV}$ was comparable between the positions. This study indicates that the left lateral tilt position may compromise the cardiac pump mechanism of chest compression in pregnant cardiac arrest patients.

Computational Investigation of Isomeric and Conformeric Structures of Methyl Fluoroperoxide and Fluoromethyl Fluoroperoxides (Methyl fluoroperoxide와 fuoromethyl fluoroperoxides의 conformers와 isomers 구조에 대한 이론연구)

  • Lee, Kyoung-Min;Sung, Eun-Mo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.405-411
    • /
    • 2011
  • The ab initio calculations for fluoromethyl fluoroperoxides have been carried out using MP2/6-311G(d,p) and B3LYP/6-311++G(d,p) method. The structural optimizations were performed for several isomers and conformers of methyl fluoroperoxide, $CH_3OOF$ and the vibrational frequencies were calculated. The most stable conformer of $CH_3OOF$ is skew form and has fairly short O-O bond distance. The trans and cis conformers have 8-12 kcal/mol higher energies than skew form and the other isomers are very unstable. The structures of $CH_2FOOF$, $CHF_2OOF$ and $CF_3OOF$ are also optimized and vibrational frequencies were calculated. These molecules also have skew forms as the lowest energy conformers. The O-O bond distances are longer and C-O bond distances are shorter than $CH_3OOF$, but the structural parameters are almost independent of the number of fluorine atoms in methyl group.

A Study on Heat Transfer Characteristics of Impinging Jet Using Infared Thermal Image Processing System (적외선열화상처리장치를 이용한 충돌제트의 전열특성에 관한 연구)

  • Kim, D.K.;Bae, S.T.;Kim, S.P.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.711-716
    • /
    • 2001
  • This paper presents an information about the heat transfer characteristics of impinging jet in eletronic equipment with infrared image processing unit. There have been many experimental investigations and theoretical studies on impinging jet because of application in a wide variety of industrial process including electronic equipment. In this study, we used infrared image processing unit to visualize heat transfer characteristics of impinging jet in electronic equipment. Infrared image processing unit is one of non-contact temperature measuring methods and it is possible to minimize flow resistance and this measurement is comparatively accurate. The main parameters are nozzle exit angle $(30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ})$ and distance between nozzle and heat source is fixed 6d("d" is diameter of circular nozzle(10 mm). Reynolds number is 4500.

  • PDF