• 제목/요약/키워드: distal extension

검색결과 126건 처리시간 0.037초

Attachment를 이용한 후방연장 국소의치에 의한 압력분산에 관한 3차원 유한요소분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE FORCE DISTRIBUTION BY DISTAL EXTENSION PARTIAL DENTURES EMPLOYING ATTACHMENTS)

  • 신상완;안원준;정연진;이영수;심광섭;유광희
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.878-887
    • /
    • 1998
  • Although attachments have been utilized for a retainer of removable prostheses during several decades, there is little information on the force distribution by the attachments. This study was undertaken to evaluate the stress patterns developed by partial dentures employing rigid attachments on the supporting structures. Four types of the mandibular removable partial dentures were designed depending upon the position of the rigid attachment and the existency of lingual bracing. Under 100N of vertical and 25N of lateral loads on the 1st and 2nd lower molar of partial denture, stress distribution patterns and displacement were analysed with three dimensional finite element method by ANSYS version 5.3. 1. The highest stresses were concentrated on the distal alveolar crest of posterior abutment and the second stresses on the apical region of posterior abutment in the models. 2. The greatest displacement were shown on the distal alveolar crest of posterior abutment and the second displacement on the distal alveolar crest of anterior abutment in the models. 3. There was little difference between the models with intraoral attachment and those with extracoronal attachment. 4. There was little difference between the models with and without the lingual bracing.

  • PDF

유리단 국소의치의 지대치 운동에 관한 생체학적 연구 (IN VIVO STUDY ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURES)

  • 이종엽;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.43-61
    • /
    • 1990
  • The laser reflexion method is a new technique which permits precise contactless measurement and observation of tooth mobility as well as tooth movement. The purposes of this study were to clarify the reliability of the laser reflexion method in clinical application and to measure the abutment tooth movement according to clasp design. This study was designed to determine 1) How much a bending movement of the impression plate stand affects the position of the reflexion pattern and how precise the patient bites into plate 2) Which clasp design causes greater movement of the abutment tooth. Under medium and maximum bite forces, tests were performed on central loading position which was 13mm distal to terminal abutment tooth of distal extension removable partial denture. The movement in the mesiodistal and buccolingual directions was measured. The Duncan's New Multiple-Range test was used to compare the means for the four castings under each direction-load combination; and the paired sample t-test was for medium and maximum bite forces. From this experiment, the following results were obtained. 1. The Roach clasp, the combination clasp, the RPI clasp, and the Akers clasp did not significantly differ in their effects on buccolingual movement of the abutment tooth. 2. The direction of abutment tooth movement was not significantly altered by clasp design and all abutment tooth movements were oriented distobuccally. 3. Under medium bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the combination clasp and the RPI clasp. Under maximum bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the RPI clasp. 4. The testing apparatus and procedures used in this study(laser reflexion method) proved to be reliable in clinical application.

  • PDF

전방 임플란트 써베이드 고정성 보철물과 후방연장 국소의치를 이용한 전악 보철 치료의 3년 경과 관찰 증례 (Three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension removable partial denture)

  • 길기성;이효경;김경아;이정진;서재민
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.218-226
    • /
    • 2018
  • 부분 무치악 환자에게 소수의 임플란트를 전략적인 위치에 식립하여 추가적인 유지와 지지를 얻는 임플란트 보조 국소의치(Implant-assisted removable partial denture, IARPD)를 제작할 수 있다. 최근 이러한 임플란트 보조 국소의치로 치료한 여러 증례와 임상가이드라인을 보면 후방 무치악 부위에 임플란트를 식립하는 것이 추천된다. 그러나 실제 임상에서는 구치부의 심한 치조골 흡수나 해부학적 이유로 외과적 수술(상악동거상술, 골 이식술 등)이 부가적으로 필요한 경우가 많다. 이에 대해 후방의 무치악 부위는 가철성 국소의치로 수복하되, 소수의 치아가 잔존하는 전방 무치악 부위는 임플란트 고정성 보철물로 수복하여 지대주로 활용하는 치료방법이 대안으로 제시될 수 있다. 본 증례는 상악 구치부 치아의 상실과 잔존치열에 중등도 이상의 마모를 보이는 환자에 대한 증례로 상악 전방부에 3개의 임플란트를 식립하고 잔존하는 상악 전치부 자연치와 더불어 각각 써베이드 고정성 보철물을 제작하였으며 상악 후방연장 국소의치를 제작하였다. 그와 함께 손상된 하악 자연치는 고정성 보철물로 전악수복하였다. 이로써 감소된 수직고경 및 붕괴된 교합평면을 회복하여 기능적, 심미적으로 향상되었으며 지속적인 경과관찰 중이다. 본 증례를 통해 전방부 임플란트 써베이드 고정성 보철물과 후방연장 국소의치에 의한 보철치료 증례의 3년 경과관찰 결과를 보고하고자 한다.

유리단국부의치(遊離端局部義齒) 사용시(使用時) 지태치(支台齒) 동요(動搖)에 대한 Splingting의 효과(效果)(II) (Effect of splinting on abutment tooth movement when a distal extension partial denture used(II))

  • 정종현
    • 대한치과기공학회지
    • /
    • 제8권1호
    • /
    • pp.85-90
    • /
    • 1986
  • The effect of splinting on aqbutment tooth distal movement was performed in vitro study. An acrylic resin mandibular model with missing 2nd premolars, molars and a removable partial denture framework were constructed. The roots of the canines, 1st premolars and edentulous ridges were coated with silicone rubber. A modified Ney Surveyor was used for vertical load appkication, and abutment tooth distal movement were measured with a dial gauge with four conditions of splinting methods were tested by applying unilateral vertical loadings. The results are follows; 1. The magnitude of abutment tooth distal movement on the non-load side was less 40$\sim$69% than that occurred on the load side. 2. On the load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(30%), non-load side double abutment(10%), double abutments of both sides(40%) was compared with single abutments of both sides. 3. On the non-load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(5%), non-load side double abutment(22%), double abutments of both sides(59%) was compared with single abutments of both sides. 4. The magnitude of abutment tooth distal movement in the condition of double abutments of both sides was less 40$\sim$59% than that in the condition of single abutments of both sides.

  • PDF

골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION)

  • 양순익;정재헌
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF