• Title/Summary/Keyword: distal

Search Result 3,187, Processing Time 0.03 seconds

Comparative Study on the Effect of Acupuncture on Local Acupoints and Distal Acupoints for Patients with Whiplash Injury (교통사고로 인한 편타성 손상 환자에 대한 원위취혈 및 근위취혈의 치료효과 비교 연구)

  • Kim, Jee-Hyun;Lee, Kyung-Min;Lim, Seong-Chul
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.2
    • /
    • pp.159-166
    • /
    • 2010
  • Objective : The purpose of this study is to compare the Effect of Acupuncture on Local Acupoints and Distal Acupoints for Patients with Whiplash Injury. Method : From January 1st 2009 to September 31th 2009, 10 patient were divided into 2 groups. One group was taken Local Acupoints, and the other group was taken Distal Acupoints. To check pain and treatment satisfaction, visual analog scale(VAS) and five-point likert scale were used before and after treatment. Result : Both acupuncture theraphy showed improvement in VAS and five-point likert scale. And Local Acupoints group showed more effective than Distal Acupoints group on five-point likert scale. Conclusion : This Study suggests that Acupuncture on Local Acupoints and Distal Acupoints can be applicable to improve symptom in Patients with Whiplash Injury.

PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS (직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석)

  • Lee Chang-Ho;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture (견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술)

  • Kim Jin Sub;Jun Jin Ho;Chung Yung Khee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.

Effectiveness of Anchoring with Balloon Guide Catheter and Stent Retriever in Difficult Mechanical Thrombectomy for Large Vessel Occlusion

  • Yi, Ho Jun;Kim, Bum-Tae;Shin, Dong-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.514-522
    • /
    • 2022
  • Objective : A distal navigation of a large bore aspiration catheter during mechanical thrombectomy (MT) is important. However, delivering a large bore aspiration catheter is difficult to a tortuous or atherosclerotic artery. We report the experience of anchoring with balloon guide catheter (BGC) and stent retriever to facilitate the passage of an aspiration catheter in MT. Methods : When navigating an aspiration catheter failed with a conventional co-axial microcatheter delivery, an anchoring technique was used. Two types of anchoring technique were applied to facilitate distal navigation of a large bore aspiration catheter during MT. First, a passage of aspiration catheter was attempted with a proximal BGC anchoring technique. If this technique also failed, another anchoring technique with distal stent retriever was tried. Consecutive patients who underwent MT with an anchoring technique were identified. Details of procedure, radiologic outcomes, and safety variables were evaluated. Results : A total of 67 patients underwent MT with an anchoring technique. Initial trial of aspiration catheter passage with proximal BGC anchoring technique was successful for 35 patients (52.2%) and the second trial with distal stent retriever anchoring was successful for 32 patients (47.8%). Overall, navigation of a large bore aspiration catheter was successful for all patients (100%) without any procedure related complications. Conclusion : Our study showed the usefulness of anchoring technique with proximal BGC and distal stent retriever during MT, especially in those with an unfavorable anatomical structure. This technique could be an alternative option for delivering an of aspiration catheter to a distal location.

Radiological Comparison between $60^{\circ}$ Distal Chevron Osteotomy and $40^{\circ}$ Distal Chevron Osteotomy in Hallux Valgus (족무지 외반증에서 $60^{\circ}$ 원위부 갈매기형 절골술과 $40^{\circ}$ 원위부 갈매기형 절골술 간의 방사선학적 비교)

  • Rha, Jong-Deuk;Park, Hyun-Soo;Lim, Chang-Suk;Jang, Young-Soo;Jeon, Yong-Soo;Jin, Hyun-Bae;Kim, Kyung-Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.146-150
    • /
    • 2005
  • Purpose: We made a radiological comparison between $60^{\circ}$ distal Chevron osteotomy with short armed two parts and $40^{\circ}$ distal Chevron osteotomy with long armed one part performing operation in cases of hallux valgus angle of less than $40^{\circ}$, intermetatarsal angle of less than $15^{\circ}$. Materials and Methods: 12 cases with $60^{\circ}$ distal Chevron osteotomy and 12 cases with $40^{\circ}$ distal Chevron osteotomy were selected from October 2000 to March 2005. We have analysed the hallux valgus angle, 1-2 intermetatarsal angle, metatarsal length, distal metartarsal articular angle and angulation at osteotomy site on lateral view in each radiological films taken at preoperative, postoperative and 3 months after operation presuming bone union. All cases were women, both sides were 9 cases and average age was 52.3 years old. Results: Data taken at preoperative, postoperative and 3 months follow up films in $60^{\circ}$ distal Chevron osteotomy were as follows; the hallux valgus angles were $32.1^{\circ}$, $10.9^{\circ}$, $13.8^{\circ}$, the 1-2 intermetatarsal angles were $13.6^{\circ}$, $8.5^{\circ}$, $8.4^{\circ}$, the metatarsal length were 60.6 mm, 58.8 mm, 58 mm, the distal metartarsal articular angles were $13^{\circ}$, $6^{\circ}$, $6.6^{\circ}$ and 3 cases were over $3^{\circ}$ angulation at lateral view. In $40^{\circ}$ distal Chevron osteotomy, the hallux valgus angles were $34.5^{\circ}$, $11.6^{\circ}$, $15.3^{\circ}$, the 1-2 intermetatarsal angles were $12.7^{\circ}$, $8.2^{\circ}$, $7.8^{\circ}$, the metatarsal length were 59.2 mm, 56.9 mm, 55.9 mm, the distal metartarsal articular angles were $12^{\circ}$, $7.3^{\circ}$, $7.3^{\circ}$ and there were no case with angulation over $3^{\circ}$ at lateral view. Conclusion: In comparison between $60^{\circ}$ distal Chevron osteotomy and $40^{\circ}$ distal Chevron osteotomy measuring at postoperative and follow up, most of all data were similar, but 3 cases over $3^{\circ}$ angulation at lateral view happened in $60^{\circ}$ Chevron osteotomy. This result showed that $40^{\circ}$ distal Chevron osteotomy fixing with screws through long armed one part may have benefit than $60^{\circ}$ distal Chevron osteotomy fixing with K-wires through short armed two parts in making rigid fixation, even though there is a personal difference of technigue.

  • PDF

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

Assessment of Compensator Thickness in Proton Therapy (양성자 치료 시 사용되는 Compensator의 Thickness에 대한 적정성 평가)

  • Park, Yong Soo;Jang, Jun Yeong;Cho, Gwang Hyeon;Park, Yong Cheol;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.35-40
    • /
    • 2018
  • Purpose : The range of force differs from the size of proton energy used in our hospital. The compensator enables to change energy size based on distal thickness which also makes changes in dose rate. Therefore, the purpose of this study is to evaluate the effect of changing the thickness of compensator distal on dose range and beam on time. Subject and Methodology : Five low energy patients who have received proton therapy were selected as subjects for this study. Beam on was checked for the selected patients during the existing therapy. After then, the thickness of distal of compensator was increased by 2 cm up to 14 cm through proton therapy plan system(TPS) for comparative analysis. For the evaluation of dose range, the value of the target's conformity index(CI) and the maximum dose of rear side target's organ at risk(OAR) were compared. Furthermore, to evaluate the effect of therapy time, beam on time was compared by making compensator distal in each thickness. Result : The result of homogeneity index and conformity index of the increased compensator distal showed the same level in all patients. The comparison results of OAR of target rear side showed 7 cGy at spine cord of abdomen at maximum, 88 cGy at eyeball's RT lens, 391 cGy at RT lens of nasal cavity 51 cGy at trachea of the mediastinum, and 661 cGy at a small bowl of the pelvis. The comparison results of the beam on time showed a reduction from 126 seconds to 62 seconds for the abdomen, from 105 seconds to 37 seconds for the eyeball, from 187 seconds to 134 seconds for nasal cavity, from 100 seconds to 40 seconds for mediastinum, from 440 seconds to 118 seconds for the pelvis. Conclusion : The research result showed that as the distal thickness of compensator increased, the size of energy increased. In addition, beam on decreased due to the increase of dose rate. It is expected that the result would help reduce the treatment time and increase the convenience of patients if it is applied to liver patients who need respiratorygated therapy and pediatric patients. However, distal penumbra increased as the size energy increased. Therefore, in treating cases where OAR is in the vicinity of the target rear side, the influence of penumbra should be taken into account in adjusting thickness level of the compensator in proton therapy plan.

  • PDF

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips (수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계)

  • Han, Seung-Kyu;Roh, Si-Young;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF