• Title/Summary/Keyword: dissolved oxygen

Search Result 1,366, Processing Time 0.03 seconds

Effects of Pressure and Dissolved Oxygen Concentration on the Activated Sludge (압력 및 용존산소 농도가 활성슬러지에 미치는 영향)

  • Yang, Byeong-Su;Sin, Hyeon-Mu;Jeong, Hyeong-Suk;Ryu, Dong-Chun;Yun, Jong-Ho;Jeong, Byeong-Gon
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.107-107
    • /
    • 1995
  • This study was conducted to evaluate the effects of pressure and dissolved oxygen concentration on the activated slut비e and to determine the optimum depth of deep shaft process. Some results from this study were summarized as follows. 1. It is considered that low sludge product in the activated sludge system maintaining high dissolved oxygen concentration is attributed to the increase of endogeneous respiration rate caused by the increase of aerobic zone in the sludge floe. 2. The increase of dissolved oxygen concentration does not affect to the increase of organic removal efficiency greatly and therefore the limiting factor is the substrate transfer into the inner part of floe. 3. The yield coefficient, Y is decreased in proportion to the increase of oxygen concentration. In this study, Y values arre ranged from 0.70 to 0.41 according to the variation of dissolved oxygen concentration from 18.0mg/$\ell$ to 258 mg/$\ell$. 4. The optimum depth of deep shaft process should be determined within the limits of non-toxicity to the microorganism and it is about loom in this study.

Evaluation of the optimal dissolved oxygen level for rainbow trout (Oncorhynchus mykiss) in the recirculating aquaculture system (순환여과 양식시스템 내 무지개송어(Oncorhynchus mykiss)의 적정 용존산소 농도평가)

  • Kunhong PARK;Jinseo CHOI;Younghun LEE;Jeonghwan PARK
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.4
    • /
    • pp.387-398
    • /
    • 2023
  • Conventional aquaculture faces declining productivity, shifting to recirculating aquaculture system (RAS), known for minimizing water usage and maintaining consistent water temperatures for year-round fish growth. Rainbow trout (Oncorhynchus mykiss), a globally important cold-water species and the third most farmed fish in inland waters of Korea, valued for its fecundity and rapid growth. Dissolved oxygen, an important environmental factor affecting fish production and economics, highlights the need for smart aquaculture practices. Since 2018, the rise of intelligent aquaculture platforms, incorporating information and communications technology (ICT), emphasizes the essential role of RAS implementation. This eight-week study aimed to determine the optimal dissolved oxygen concentration for rainbow trout in RAS, utilizing a device for continuous monitoring, control and record. Dissolved oxygen concentrations were set at 5-6 mg/L, 9-10 mg/L, 14-15 mg/L and 17-18 mg/L. The growth rate significantly decreased at 5-6 mg/L, with no significant differences in other experimental groups. In hematological analysis, growth hormone (GH) was significantly highest at 5-6 mg/L, followed by 9-10 mg/L while Insulin-like growth factor-1 (IGF-1) was significantly lowest at 5-6 mg/L. In conclusion, the optimal dissolved oxygen concentration for rainbow trout in RAS is approximately 9-10 mg/L. Higher concentrations do not contribute to further growth or profitability.

The effect of dissolved oxygen and initial complextation of Cu(II) and EDTA on photooxidation of Cu(II)-EDTA by TiO2 (TiO2 광측매를 이용한 Cu(II)-EDTA의 산화에서 용존산소와 Cu(II)와 EDTA 초기 당량의 영향)

  • 정흥호;성기웅;조영현;이영석;최상원
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.85-91
    • /
    • 2002
  • The effects of initial concentration of dissolved oxygen content, Cu(II) and EDTA in an aqueous Cu(II)-EDTA solution on $TiO_2$ photo-oxidation of EDTA were investigated using $TiO_2$ (Degussa P-25) and UV irradiation at $20{\circ}C$. In the presence of dissolved oxygen and/or Cu(II) the photo-oxidation rates of EDTA were enhanced. The rates linearly increased in the range of initial Cu(II) concentration below 1.79 mM, while abode this concentration those were kept constant. The trend or the EDTA photo-oxidation rates appeared to be akin to the Langmuir-Hinshelwood equation farm and the k values calculated were 0.05 mM/min for the free-EDTA system, and 0.17 mM/min far the Cu(II)-EDTA system. These meant the aqueous EDTA decomposition was enhanced due to weakening of the intra-molecular bond strength of EDTA by complexation with Cu(II) added. It was concluded the decomposition of aqueous EDTA by $TiO_2$ photo-oxidation was maximum in the presence of dissolved oxygen supplied by air purging and of Cu(II) with its concentration for 1:1 Cu(II)-EDTA complexation ratio.

Design and Fabrication of Portable Dissolved Oxygen Measurement System (휴대용 용존산소 측정 시스템의 설계 및 제작)

  • Chang, Choong-Won;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.219-223
    • /
    • 2008
  • The dissolved oxygen (DO) sensors were fabricated by screen printing method, and potable dissolved oxygen measurement system was fabricated for low cost products. The fabricated sensors had high current change and fast response according to dissolved oxygen concentrations in the applied voltage of 0.7 V. The DO measurement system was consisted of MCV, amplifier, filter, power supply and display. DO concentrations were programed to display as digital percentages by converting the analog value. It is expected that the fabricated DO measurement system can replace the expensive commercial DO meter, because it reveals the high accuracy of ${\pm}0.5%$ to the standard solution and the response time of about 100 sec like the commercial DO meter.

  • PDF

Hydroxylamine Effect on the Determination of Dissolved Oxygen by the Azide-Modified Winkler Method and Polarography (修正된 아자이드 Winkler 법과 폴라로그래피에 의한 溶存酸素의 측정에 관한 하이드록실아민의 영향)

  • Chung, Keun Ho;Ree, Jony Iuir;Kim, Chun Seek
    • Journal of Environmental Health Sciences
    • /
    • v.12 no.2
    • /
    • pp.11-15
    • /
    • 1986
  • Hydroxlamine effect on the determination of dissolved oxygen by the azide-modified Winkder method and polarography has been studied. It was found that hydroxylamine interference on the dissolved oxygen by the azide-modified Winklet method can be eliminated completely by using permanganate. An inexpensive and convenient polarograph device was constructed. Dissolved oxygen in an air-saturated 0.1 F KCl solution undergoes, independent of hydroxylamine concentrations a two-step irreversible reduction at the dropping electrode the $H_2O_2$ produced in the first step is reduced to $H_2$O in the second. Two waves of equal size result, the first with a half-wave potential (E1/2) at about -0.13 V and the second at about -0.91 V (vs. SCE).

  • PDF

Early Summer Dissolved Oxygen Characteristics in Restored Streams in Seoul (서울시 복원하천들의 초여름 용존 산소량 특성 분석)

  • Thoenen, Casey;Choi, Woonsup;Choi, Jinmu
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.3
    • /
    • pp.336-347
    • /
    • 2013
  • This paper presents an evaluation of stream restoration projects in Seoul with a focus on dissolved oxygen. Five test sites across four streams were measured for dissolved oxygen (DO) in late May to early June in 2012 and compared against a set of minimum and maximum thresholds. Only one test site, Hwarang-cheon, showed measurements below 6 mg/l DO. Towards the upper limit, the Hwarangcheon site was the only tested stream which was not at risk of DO supersaturation. The Danghyeon-cheon site had the highest probability of supersaturation, with DO saturation exceeding 130% expected 86.5% of the time. When measured every hour during daytime, DO levels showed diurnal variations, peaking in the afternoon. However, they showed inconsistent results along transects of the streams. Overall, the streams are rich in DO. To maintain the streams in good standing, nutrient loading should be addressed to prevent potential algal bloom induced hypoxic events down the line.

  • PDF

Release of Oxygen from a Nano-sized Water Droplet Observed using Molecular Dynamics

  • Lee, Chang-Han;Ambrosia, Matthew Stanley
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.927-935
    • /
    • 2016
  • Dissolved oxygen is necessary for many biological processes as well as many industrial practices. Dissolved oxygen released from water in dissolved air flotation (DAF) systems can be have many different applications. However, DAF systems are very costly to operate. To develop more efficient DAF systems, a deeper understanding of the process of oxygen being released from water is required. In this study, molecular dynamics (MD) simulations were used to simulate 100 oxygen molecules surrounded by 31002 water molecules at temperatures ranging from $0^{\circ}C$ to $100^{\circ}C$. Simulations were carried out for 10 ns, during which, in most cases, all the oxygen molecules were released from the water droplet. With MD simulations, visualization of the molecules escaping the water droplet was possible, which aided the understanding of the interactions between molecules at the nano-scale. The results showed that as the oxygen molecules moved near the edge of the water droplet that the oxygen molecules hesitated before escaping the water droplet or returned to the interior of the water droplet. This was because of the attractive forces between the water and oxygen molecules. Moreover, after most of the oxygen molecules were released from the droplet, some were found to return to the droplet's edge or even the interior of the droplet. It was also confirmed that oxygen molecules were released at a faster rate at higher temperatures.

Dissolved Oxygen at the Bottom Boundary Layer of the Ulleung Basin, East Sea (동해 울릉분지 해저 경계면의 용존산소)

  • Kang, Dong-Jin;Kim, Yun-Bae;Kim, Kyung-Ryul
    • Ocean and Polar Research
    • /
    • v.32 no.4
    • /
    • pp.439-448
    • /
    • 2010
  • General consensus on typical vertical profile of dissolved oxygen in the Ulleung Basin is that dissolved oxygen concentration beyond 300 m decreases with increasing depth. However, the results of our observations in 2005 and 2006 revealed three different dissolved oxygen distribution types in the deep layer of the Ulleung Basin. The first type showed oxygen concentration decreasing with increasing depth (Type-1), the second showed oxygen concentration decreasing very sharply near the bottom boundary layer but constant in the bottom adiabatic layer (Type-2), the final was of the oxygen minimum layer above the bottom boundary layer (Type-3). Type-2 was the most common pattern in the Ulleung Basin. Type-1 was most common close to the Japan Basin, including the Ulleung Interplane Gap, while Type-3 was found around Dok do. Oxygen Consumption Rate (OCR) at surface sediment estimated using the dissolved oxygen distribution at the bottom boundary layer was $0.2{\sim}5.8\;mmol{\cdot}m^{-2}d^{-1}$, which coincided with OCR from direct sediment incubation. This implies that organic matter decomposition at surface sediment may play an important role in dissolved oxygen distribution patterns at the bottom boundary layer of the Ulleung Basin.

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF