• 제목/요약/키워드: dissolved oxygen

검색결과 1,374건 처리시간 0.036초

스크린 인쇄법에 의한 용존 산소센서의 제조 및 특성 (Fabrication of Dissolved Oxygen sensors by Screen Print Method and Characteristic)

  • 정경진;이성필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.926-929
    • /
    • 2003
  • The dissolved oxygen sensor of thick film type was fabricated by screen print method and measured the characteristic, reference electrode used Ag/AgCl, and working electrode used Pt. The devices are continuously powered at potential of $0.7V{\sim}0.8V$ versus Ag/AgCl reference electrode and results indicated that the response characteristic of sensor was $1.002{\mu}A{\sim}19.792{\mu}A$ for thirty seconds. we can know that it is good linearity when compared with of existent dissolved oxygen meter. Therefore sensor fabricated excels sensitivity for dissolved oxygen and will be considered to be applied typically because the price is costly.

  • PDF

후막형 용존 산소 센서의 전기적 특성 (Electrical properties of thick film dissolved oxygen sensors)

  • 이경준;정경진;이성필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.92-95
    • /
    • 2003
  • The dissolved oxygen sensors with thick film type were fabricated for low cost products and the electrical properties were investigated in the different operating temperatures. Pt paste was used for working electrode and Ag/AgCl paste for reference electrode. The fabricated devices have fast response of current changes according to dissolved oxygen concentrations in the applied voltage of $0.6{\sim}0.8V$. This is expected to apply a chip and/or disposal dissolved oxygen sensors.

  • PDF

北西地中海에 위치하며 염도변화가 심한 부영양화 湖水 Etang de Berre 와 隣接淡水. 海水의 溶存酸素量 硏究 (L'Oxygene Dissous dans une Lagone Eutrophisee a Salinite Variable (Etang de Berre;Mediterranee Nord-Occidentale) et dans les Eaux Douces et Marines Adjacentes)

  • 마르크;김기태
    • 한국해양학회지
    • /
    • 제21권4호
    • /
    • pp.211-228
    • /
    • 1986
  • 北西 地中海에 位置한 Etang de Berre 와 이곳에 流入되는 4개 하천 및 이웃 한 Carry-le-Rouet 海域에서, 1976年 12月까지 용존산소량의 농도와 포화도의 시공간적인 分布가 생태학적 한 요인으로서 조사. 연구되었다.

  • PDF

마이크로플레이트 기반 생물반응기 시스템 (MABOOMSTM)을 이용한 대장균 배양공정에서 용존산소, pH 및 세포농도의 온라인 모니터링 연구 (Study on Online Monitoring of Dissolved Oxygen, pH and Cell Concentration in E. coli Cultivation Processes Using MABOOMSTM)

  • 손옥재;이종일
    • KSBB Journal
    • /
    • 제28권1호
    • /
    • pp.24-30
    • /
    • 2013
  • Dissolved oxygen, pH and cell concentration have been online monitored in cultivation processes with Escherichia coli by using a $MABOOMS^{TM}$ (microplate-based bioreactor with optical online monitoring systems). Fluorescent sensing membranes containing Ru ${(dpp)_3}^{2+}$ or HPTS were prepared with GA sol-gel matrix and coated into a well of a 24-well microplate. Fluorescence intensity was measured and correlated to the dissolved oxygen or pH. Cell concentrations were also online monitored by measuring optical reflectance at 650 nm. A well of a 24-well microplate could also be divided into 4 parts, each of which was coated with fluorescent sensing membranes for the detection of dissolved oxygen or pH. The 24-well microplate coated with fluorescent sensing membranes or a 4-divided sensing membrane. was used to online monitor the dissolved oxygen, pH and cell concentration during E. coli cultivations. The online monitoring results showed the characteristics of cell growth in cultivation processes very well.

Control of Both Foam and Dissolved Oxygen in the Presence of a Surfactant for Production of $\beta$-Carotene in Blakeslea trispora

  • Kim, Seon-Won;Lee, In-Young;Jeong, Jae-Cheol;Lee, Jung-Heon;Park, Young-Hoon
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권5호
    • /
    • pp.548-553
    • /
    • 1999
  • A production of $\beta-Carotene$was attempted in a fed-batch culture of Blakeslea trispora by controlling both foam and dissolved oxygen in the presence of surfactant, Span 20. Results obtained from the shake flask cultures indicated that a high concentration of dissolved oxygen was needed for both cell growth and $\beta-Carotene$ synthesis, and the optimal concentration of glucose was found to be in the range of 50-100 g/l. In order to maintain the dissolved oxygen concentration level at higher than 50% of air saturation, pure oxygen was automatically sparged into the medium with air. Foam was controlled by bypassing air from the submerged aeration to the headspace in response to the foam that was caused by Span 20. High agitation speed was found to be detrimental to the cell growth due to shear damage, even though it provided sufficient dissolved oxygen. On the other hand, a low aeration speed caused stagnant regions in the fermentor because of improper mixing. Thus, for the fed-batch operation, agitation speed was increased gradually from 300 to 700 rpm to prevent cell damage at the initial stage of fermentation and to give efficient mixing for a viscous culture broth as the culture proceeded. By controlling dissolved oxygen and foam, a high concentration of $\beta-Carotene$otene (1,190 mg/l) was obtained in 6 days of the fed-batch culture of B. trispora with 2.5% of the dry cell weight, which was approximately 5 times higher than that of the batch cultures.

  • PDF

용존 산소 측정용 초소형 Clark-type 센서에 대한 연구 (A Study on the Microfabricated Clark-type Sensor for Measuring Dissolved Oxygen)

  • 박정일;장종현;최명기;이동영;김영미;박정호
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1450-1454
    • /
    • 2007
  • This paper presents a microfabricated Clark-type sensor which exactly can measure dissolved oxygen in the cell containing solution. We designed, fabricated, and characterized a microfabircated Clark-type oxygen sensor for measuring dissolved oxygen. The microfabricated oxygen sensor consists of 3-electrodes on a glass substrate, a FEP (Fluorinated ethylene propylene) oxygen-permeable membrane, and PDMS (Polydimethylsiloxane) reservoir for storing sample solution. Thin-film Ag/AgCl was employed as a reference electrode and its durability was verified by obtaining a stable open circuit potential for 2 hours against a commercial Ag/AgCl electrode and a stable cyclic voltammetry curve. Selectivity, response time, and linearity of the fabricated oxygen sensor were also verified well by cyclic voltammetry and amperometry depending. The fabricated oxygen sensor showed a 90% response time of 40sec and an excellent linearity with a correlation coefficient of 0.994.

영산호 수온과 용존산소의 계절적 변화에 관한 연구 (Seasonal Variation of Water Temperature and Dissolved Oxygen in the Youngsan Reservoir)

  • 박용우;조기안;조철
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.44-53
    • /
    • 2008
  • To recognize the spatial and temporal variability of water temperature and dissolved oxygen in the Youngsan reservoir formed after dike construction, water temperature and dissolved oxygen data have been observed and analyzed from April, 2002 until March, 2003. As the results, certain stratifications were not distinctly observed in the Youngsan reservoir during summer, which was estimated due to the drainage characteristic from the Youngsan water gates. The yearly variation of water temperature in the Youngsan reservoir is shown seasonally ups and downs by the heat exchange between the atmosphere and the reservoir. On the other hand, dissolved oxygen and water temperature in the Youngsan reservoir have been shown inversed proportional correlation. As the calculation results of residence time and water exchange rate, it is considered that the feature of oxygen distribution is determined by the drainage characteristics caused the shortest residence time during summer, which also disturbed the formation of stratification in the Youngsan reservoir.

Dissolved Oxygen Removal in a Column Packed with Catalyst

  • Lee, Han-Soo;Hongsuk Chung;Cho, Young-Hyun;Ahn, Do-Hee;Kim, Eun-Kee
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.482-487
    • /
    • 1996
  • The dissolved oxygen removal by H$_2$-O$_2$ reaction in column packed with various catalysts wes examined. The catalysts employed were the prepared polymeric catalyst platinum on activated carbon, and Lewatit OC-1045 which is available commercially. The column experiments with the prepared polymeric catalyst showed the dissolved oxygen reduced to 35 ppb which is below the limit in feed water of power plants. This implies the likely application of the prepared catalyst for practical use. The activated carbon required the pre-treatment for the removal of dissolved oxygen, since the surface of activated carbon contains much oxygen adsorbed initially. The Lewatit catalyst exposed the best performance, however, the aged one showed the gradual loss of catalytic activity due to degradation of resin catalyst.

  • PDF

산소감응성 입자 제조 및 특성 분석 연구 (Fabrication of Oxygen Sensitive Particles and Characteristic Analysis)

  • 정원택;이승재;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.41-46
    • /
    • 2011
  • Oxygen sensitive functional particles(OSParticle) were fabricated by three different methods for using the particles as oxygen sensors and PIV tracers. The used methods were a physical coating method, an ion-exchange method and a dispersion polymerization method. The physical coating method is dipping $SiO_2$ hollow particles into dye solution then drying. This method is very simple, but particles are not uniform in diameter and luminescence. The particles fabricated by the ion-exchange method have very uniform diameter and well doped. However, it can not be used in water since the particles are hydrophobic. In case of the dispersion polymerization method, the diameter of OSParticles is quite uniform. The diameter of OSParticles can be changed by controlling the quantity of AIBN (2,2'-azobis isobutyronitrile). For the purpose of dissolved oxygen concentration measurement in micro scale water flows, the dispersion polymerized OSParticles turn out to be the most superior functional particles. The luminescent intensity of OSParticles was tested with the variation of dissolved oxygen concentration in water samples. As a result, the luminescent intensity of OSParticles is monotonically decreased with increasing DO (Dissolved oxygen) concentration of water.

Novel oxygenation for lipopeptide production from Bacillus sp. GB16

  • Lee, Baek-Seok;Lee, Jae-Woo;Shin, Haw-Shook;Choi, Sung-Won;Choi, Ki-Hyun;Lee, Jae-Ho;Kim, Eun-Ki
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.240-244
    • /
    • 2003
  • A novel integrated method for increasing dissolved oxygen concentration in culture media has been developed. It involves adding hydrogen peroxide to the medium, which is then decomposed to oxygen and water by catalase and adding vegetable oil to the medium as antifoam agent and oxygen vector. A new apparatus for automated addition of hydrogen peroxide to the bioreactor to keep the dissolved oxygen concentration constant over the range $10-100%\;{\pm}\;5%$ was tested. A significant increase (over threefold) of cultivation time was obtained while the dissolved oxygen concentration remained stable ($30%\;{\pm}\;5%$). Therefore, use of corn oil mixed with Ca-stearate as oxygen vector and antifoam and hydrogen peroxide as oxygen source to control excessive foam that was generated by microorganism biosurfactant, GB16-BS produced at Bacillus sp. GB16 cultivation was appropriate for stable cultivation.

  • PDF