• 제목/요약/키워드: dissolution testing

검색결과 38건 처리시간 0.026초

Effect of pH and Concentration on Electrochemical Corrosion Behavior of Aluminum Al-7075 T6 Alloy in NaCl Aqueous Environment

  • Raza, Syed Abbas;Karim, Muhammad Ramzan Abdul;Shehbaz, Tauheed;Taimoor, Aqeel Ahmad;Ali, Rashid;Khan, Muhammad Imran
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.213-226
    • /
    • 2022
  • In the present study, the corrosion behavior of aluminum Al-7075 tempered (T-6 condition) alloy was evaluated by immersion testing and electrochemical testing in 1.75% and 3.5% NaCl environment at acidic, neutral and basic pH. The data obtained by both immersion tests and electrochemical corrosion tests (potentiodynamic polarization and electrochemical impedance spectroscopy tests) present that the corrosion rate of the alloy specimens is minimum for the pH=7 condition of the solution due to the formation of dense and well adherent thin protective oxide layer. Whereas the solutions with acidic and alkaline pH cause shift in the corrosion behavior of aluminum alloy to more active domains aggravated by the constant flux of acidic and alkaline ions (Cl- and OH-) in the media which anodically dissolve the Al matrix in comparison to precipitated intermetallic phases (cathodic in nature) formed due to T6 treatment. Consequently, the pitting behavior of the alloy, as observed by cyclic polarization tests, shifts to more active regions when pH of the solutions changes from neutral to alkaline environment due to localized dissolution of the matrix in alkaline environment that ingress by diffusion through the pores in the oxide film. Microscopic analysis also strengthens the results obtained by immersion corrosion testing and electrochemical corrosion testing as the study examines the corrosion behavior of this alloy under a systematic evaluation in marine environment.

산성안개 환경하에서 Ni-Cr-Mo 강의 피로크랙전파거동 (Fatigue Crack Growth Behavior of Ni-Cr-Mo Steel under Acid Fog Environment)

  • 김민건;임용호;김만구
    • 대한기계학회논문집A
    • /
    • 제24권7호
    • /
    • pp.1841-1846
    • /
    • 2000
  • To examine the effect of acid fog on the corrosion fatigue behavior in structural steel, fatigue tests under acid fog atmosphere were carried out in comparison with distilled water. The corrosive c omponents contained in acid fog pile up the corrosion products on crack face and show a crack branching and crack tip blunting. Therefore, due to these workings crack growth rate was reduced by decreasing the effective stress range in crack tip rather than under distilled water. Also the effect of sulfuric acid, which is the main component of acid fog, and testing speed on fatigue crack growth were examined. It was found that corrosion behavior was remarkably dependent upon pH and Hz rather than components of acid fog. According as pH and testing speed decrease below a specific value, crack growth was accelerated in comparison with distilled water. This reveals that due to liquid having strong acidity and slow speed of test the crack face dissolution was promoted, so crack closure was disturbed in the process of stress descent.

Characterisation and Durability of a Vitrified Wasteform for Simulated Chrompik III Waste

  • Walling, Sam A.;Gardner, Laura J.;Pang, H.K. Celine;Mann, Colleen;Corkhill, Claire L.;Mikusova, Alexandra;Lichvar, Peter;Hyatt, Neil C.
    • 방사성폐기물학회지
    • /
    • 제19권3호
    • /
    • pp.339-352
    • /
    • 2021
  • Legacy waste from the decommissioned A-1 nuclear power plant in the Slovak Republic is scheduled for immobilisation within a tailored alkali borosilicate glass formulation, as part of ongoing site cleanup. The aqueous durability and characterisation of a simulant glass wasteform for Chrompik III legacy waste, was investigated, including dissolution experiments up to 112 days (90℃, ASTM Type 1 water). The wasteform was an amorphous, light green glassy product, with no observed phase separation or crystalline inclusions. Aqueous leach testing revealed a suitably durable product over the timescale investigated, comparing positively to other simulant nuclear waste glasses and vitreous products tested under similar conditions. Iron and titanium rich precipitates were observed to form at the surface of monolithic samples during leaching, with the formation of an alkali deficient alteration layer behind these at later ages. Overall this glass appears to perform well, and in line with expectations for this chemistry, although longer-term testing would be required to predict overall durability. This work will contribute to developing confidence in the disposability of vitrified Chrompik legacy wastes.

산-염소이온 분위기의 인자전위에 따른 내후성강 용접부의 부식파괴에 관한 연구 (A Study on Corrosion Failure of a Weathering Steel Weldment with Various Applied Potentials in Acid-chloride Solution)

  • 최윤석;김정구;김종집;이병훈
    • Journal of Welding and Joining
    • /
    • 제18권3호
    • /
    • pp.97-105
    • /
    • 2000
  • The stress corrosion cracking(SCC) and hydrogen embrittlement cracking(HEC) characteristics of a weathering steel weldment were investigated in aerated acid-chloride solution. The electrochemical properties of weldment were investigated by polarization test and galvanic corrosion test. Weathering steel did not show passive behavior in the acid-chloride solution. Galvanic corrosion between the weld metal and the base metal was not observed because the base metal was anodic to the weld metal. The slow-strain-rate tests(SSRT0 were conducted at a constant strain rate o 7.87×{TEX}$10^{-7}${/TEX}/s at corrosion potential, and at potentiostatically controlled anodic and cathodic potentials. The weldment of weathering steel was susceptible to both anodic dissolution SCC and hydrogen evolution HEC.

  • PDF

서방성 경구제형의 개발과 평가 및 생체내.외 상관성 연구를 위한 가이드라인 (Guideline for Extended Release Oral Dosage Forms : Development, Evaluation, and Application of In Vitro/In Vivo Correlations)

  • 최선옥;정성희;엄소영;정서정;김주일;김옥희
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권6호
    • /
    • pp.471-481
    • /
    • 2005
  • In Korea, generic drug and bioequivalence test are the hot issues since a new medical system of separation of dispensary from medical practice was started in 2000. The KFDA(Korea FDA) had revised several times ${\ulcorner}Guidance\;for\;bioequivalence\;test{\lrcorner}$. In vitro dissolution test has been extensively used as a quality control tool for solid oral dosage forms. In an effort to minimize unnecessary human testing, in vitro/in vivo correlations (IVIVC) between in vitro dissolution and in vivo bioavailability are increasingly becoming an integral part on extended release drug product development. The recently published US guidance, ${\ulcorner}Extended\;release\;oral\;dosage\;forms\;:\;development,\;evaluation,\;and\;application\;of\;in\;vitro/in\;vivo\;correlations{\lrcorner}$ will be helpful for us to make our own guideline.

하이드록시아파타이트/포스터라이트 복합분말의 분사코팅에 의한 3Y-TZP 기판의 표면개질과 생체활성 증진 (Surface Modification and Bioactivity Improvement of 3Y-TZP Substrate by Spray Coating of Hydroxyapatite/Fosterite Composite Powder)

  • 윤유현;이종국
    • 한국재료학회지
    • /
    • 제33권8호
    • /
    • pp.337-343
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals) ceramics have excellent mechanical properties including high fracture toughness, good abrasion resistance as well as chemical and biological stability. As a result, they are widely used in mechanical and medical components such as bearings, grinding balls, and hip implants. In addition, they provide excellent light transmittance, biocompatibility, and can match tooth color when used as a dental implant. Recently, given the materials' resemblance to human teeth, these ceramics have emerged as an alternative to titanium implants. Since the introduction of CAD/CAM in the manufacture of ceramic implants, they've been increasingly used for prosthetic restoration where aesthetics and strength are required. In this study, to improve the surface roughness of zirconia implants, we modified the 3Y-TZP surface with a biocomposite of hydroxyapatite and forsterite using room temperature spray coating methods, and investigated the mixed effect of the two powders on the evolution of surface microstructure, i.e., coating thickness and roughness, and biological interaction during the in vitro test in SBF solution. We compared improvement in bioactivity by observing dissolution and re-precipitation on the specimen surface. From the results of in vitro testing in SBF solution, we confirmed improvement in the bioactivity of the 3Y-TZP substrate after surface modification with a biocomposite of hydroxyapatite and forsterite. Surface dissolution of the coating layer and the precipitation of new hydroxyapatite particles was observed on the modified surface, indicating the improvement in bioactivity of the zirconia substrate.

Development and assessment of nano drug delivery systems for combined delivery of rosuvastatin and ezetimibe

  • Mohamed Ali Metwally;El-Yamani Ibrahim El-Zawahry;Maher Amer Ali;Diaa Farrag Ibrahim;Shereen Ahmed Sabry;Omnia Mohamed Sarhan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제28권3호
    • /
    • pp.275-284
    • /
    • 2024
  • Worldwide, cardiovascular disease is the main cause of death, which accordingly increased by hyperlipidemia. Hyperlipidemia therapy can include lifestyle changes and medications to control cholesterol levels. Statins are the medications of the first choice for dealing with lipid abnormalities. Rosuvastatin founds to control high lipid levels by hindering liver production of cholesterol and to achieve the targeted levels of low-density lipoprotein cholesterol, another lipid lowering agents named ezetimibe may be used as an added therapy. Both rosuvastatin and ezetimibe have low bioavailability which will stand as barrier to decrease cholesterol levels, because of such depictions, formulations of this combined therapy in nanotechnology will be of a great assistance. Our study demonstrated preparations of nanoparticles of this combined therapy, showing their physical characterizations, and examined their behavior in laboratory conditions and vivo habitation. The mean particle size was uniform, polydispersity index and zeta potential of formulations were found to be in the ranges of (0.181-0.72) and (-13.4 to -6.24), respectively. Acceptable limits of entrapment efficiency were affirmed with appearance of spherical and uniform nanoparticles. In vitro testing showed a sustained release of drug exceeded 90% over 24 h. In vivo study revealed an enhanced dissolution and bioavailability from loaded nanoparticles, which was evidenced by calculated pharmacokinetic parameters using triton for hyperlipidemia induction. Stability studies were performed and assured that the formulations are kept the same up to one month. Therefore, nano formulations is a suitable transporter for combined therapy of rosuvastatin and ezetimibe with improvement in their dissolution and bioavailability.

공정서 수재 의약품의 정량법 개선에 관한 연구 (Establishment of Quantitative Method for Generic Drugs in Korea Pharmaceutical Codex Monograph)

  • 송재용;장진섭;장승은;김선회;김인규;이길봉;이제만;김용희
    • 약학회지
    • /
    • 제56권5호
    • /
    • pp.288-292
    • /
    • 2012
  • The aim of the paper is to ameliorate old research methods of Korean Pharmaceutical Codex to adjust the newest scientistic level which is necessary to maintain quality of medical supplies effectively. After reviewing result of Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph, there are two items chosen for the methods - Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph which KFDA researched in 2010, arranged new measuring standard by having an experiment to set measuring method after obtaining each item. According to the result, The experiment includes a measuring method of two items; Nafronyl Oxalate Capsules, and Ticlopidine Hydrochloride Tablets. The research is ameliorated by research methods through several experiments such as High Performance Liquid Chromatography validation, preparing items, implement of trial-experiment and authentic experiment, and experiment on measuring method of regulations of Korea Pharmaceutical Codex. The experiments are taken opinions of experts in KFDA into consideration and wrote out a report of the new measuring method on each last item. The report is combined as each two experiment sections of analyzing method to maintain the quality on the basis of the research in 2010 on setting of dissolution specifications for oral solid dosage forms. The result of measuring method of medical supplies through modernizing trial method of oral solid dosage forms is available to be accurate. In conclusion, this study could contribute to promotion of public health by organizing a basis for safe and high quality of medical supplies in domestic market.

낙동강 중 · 상류지역 하천의 표류수 및 퇴적층의 중금속 및 수질분석 (Analysis of Water Quality and Heavy Metals for Surface Water and Sediments of Upstream and Midstream in Nakdong River)

  • 이창섭
    • 대한화학회지
    • /
    • 제44권6호
    • /
    • pp.547-555
    • /
    • 2000
  • 대구${\cdot}$경북지역의 상수원 및 공업용수로서 사용되고 있는 낙동강 중${\cdot}$상류지역 하천 표류수의 수질을 분석하고, 하상 퇴적층에 함유된 중금속과 유기물의 종류 및 함유량을 분석하였다. 시료 채취는 갈수기 중 6월 22, 23 양일간 안동댐 상류 청량산 도립공원 양삼교 밑을 제 1지점으로 하여, 경북 지방을 통과하는 낙동강의 최하단인 고령군 고령교까지, 주로 공단의 전후 및 하천의 합류 지점을 대상으로 총 10개 지점에서 실시하였다. 표류수의 분석은 표류수의 시험항목 중 암모니아성 질소, 아질산성 질소, COD 등 총 22개 항목에 대하여 수행하였으며, 퇴적층은 trichloroethylene 등의 유기물과 중금속 등 11개 항목에 대하여 분석하였다. 퇴적물 시료는 용출시험법 및 산분해법으로 각각 분석하여 결과를 비교하였으며, 시료 중 중금속 성분은 유도결합 플라스마 방출분광법으로 분석하였고, 기타 성분은 환경부기준 공정시험방법에 의하여 분석하였다.

  • PDF

Chitosan-Coated Fe3O4 Magnetic Nanoparticles as Carrier of Cisplatin for Drug Delivery

  • Arum, Yosefine;Oh, Yun-Ok;Kang, Hyun Wook;Ahn, Seok-Hwan;Oh, Junghwan
    • Fisheries and Aquatic Sciences
    • /
    • 제18권1호
    • /
    • pp.89-98
    • /
    • 2015
  • A synthesis method for a chitosan-coated magnetic drug-delivery system of cisplatin is proposed. Here, cisplatin was conjugated to the surface of Magnetite ($Fe_3O_4$) nanoparticles via a (3-Aminopropyl)-trimethoxysilane (APTS) coupling agent. To reduce the cytotoxic effect of cisplatin, the magnetic drug was then encapsulated in chitosan (CS-cisplatin-$Fe_3O_4$) through the water/oil (W/O) emulsion method. The CS-cisplatin-$Fe_3O_4$ nanoparticles were synthesized in a spherical shape with a diameter of 190 nm. The cytotoxicity assay was performed using HeLa cells. The cisplatin uptake of the cells was determined using High Performance Liquid Chromatography (HPLC) to calculate the drug content. The controlled release of cisplatin was demonstrated by regulating the dissolution and diffusion of the drug through the chitosan matrix.