• 제목/요약/키워드: dissipation factor

검색결과 394건 처리시간 0.029초

BCB Polymer Dielectrics for Electronic Packaging and Build-up Board Applications

  • Im, Jang-hi;Phil-Garrou;Jeff-Yang;Kaoru-Ohba;Masahiko-Kohno;Eugene-Chuang;Jung, Moon-Soo
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.19-25
    • /
    • 2000
  • Dielectric polymer films produced from benzocyclobutene (BCB) formulations (CYCLOTENE* family resins) are known to possess many desirable properties for microelectronic applications; for example, low dielectric constant and dissipation factor, low moisture absorption, rapid curing on hot plate without reaction by-products, minimum shrinkage in curing process, and no Cu migration issues. Recently, BCB-based products for thick film applications have been developed, which exhibited excellent dissipation factor and dielectric constant well into the GHz range, 0.002 and 2.50, respectively. Derived from these properties, the applications are developed in: bumping/wafer level packaging, Ga/As chip ILD, optical waveguide, flat panel display, and lately in BCB-coated Cu foil for build-up board. In this paper, we review the relevant properties of BCB, then the application areas in bumping/wafer level packaging and BCB-coated Cu foil for build-up board.

  • PDF

6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성 (Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 한국전기전자재료학회논문지
    • /
    • 제25권4호
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Breakdown Strength Estimation of Non-Cellulosic Insulating Materials Used in Electrical Power Equipment

  • Singh, Sakshi;Mohsin, Mirza Mohd.;Masood, Aejaz
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권6호
    • /
    • pp.338-340
    • /
    • 2017
  • Breakdown of solid insulating materials in power equipment could result in undesired outages and replacements, and may be due to an increase in electric stress on the material. Therefore, it is necessary to conduct a proper diagnosis of materials before their practical use. In this work, a few inherent properties of different non-cellulosic insulating materials, such as Nomex, Teflon, laminated Nomex, glass bonded mica, epoxy resin bonded mica paper, and epoxy resin bonded fiberglass, have been evaluated by performing non-destructive dielectric diagnostic measurements, and an attempt has been made to correlate these basic parameters to evaluate the breakdown strength (BDS). An equation has been proposed using a basic theory which defines the correlation between the BDS, dielectric constant, dissipation factor, sample thickness, and volume resistivity. The results obtained from the equation are also compared with the experimental values. The suggested equation will be helpful to predict the BDS of any non-cellulosic material without experimentation in the laboratory.

Investigation on the Dielectric, Physical and Chemical Properties of Palm Oil and Coconut Oil under Open Thermal Ageing Condition

  • Mohamad, Nur Aqilah;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.690-698
    • /
    • 2016
  • In this paper, a study is carried out to investigate the dielectric, physical and chemical properties of Palm Oil (PO) and Coconut Oil (CO) under open thermal ageing condition. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The ageing experiment was carried out at 85 ℃ and 115 ℃ for 1, 3, 5, 7 and 14 days. Several parameters were measured such as AC breakdown voltage, dielectric dissipation factor, relative permittivity, resistivity, viscosity, moisture and acidity throughout the ageing duration. Based on the study, it is found that there are no significant changes on the AC breakdown voltages and relative permittivities for both RBDPO and CO. At ageing temperature of 115℃, there are clear reduction trends of dielectric dissipation factor for CO and resistivities for most of RBDPO. On the other hand, no clear trends are observed for viscosities, moisture and acidities of RBDPO and CO throughout the ageing duration.

수열법에 의해 합성된$(Pb,La)TiO_3$분말의 소결 및 유전특성 (Sintering and dielectric properties of $(Pb,La)TiO_3$ powder prepared by hydrothermal method)

  • 김갑영;김판채;황완인;최종건
    • 한국결정성장학회지
    • /
    • 제11권6호
    • /
    • pp.246-251
    • /
    • 2001
  • 수열법으로 $(Pb_{1-x}$La_{2x/3})TiO_3$(PLT, X=0.2) 분말을 합성한 후, $MnO_2$를 0.00~0.02 mol% 첨가하여 그에 따른 소결거동 및 유전특성을 조사하였다. PLT 소결체의 상대밀도는, Mn이 0.02 mol% 첨가되고 $1150^{\circ}C$에서 5시간 소결할 경우 96.7%이였다. PLT의 유전특성은, $MnO_2$의 함량과 소결온도의 변화에 따라 변하였다. Mn의 첨가나 소결온도의 증가시 유전손실값은 측정온도의 증가에 따라 증가되었다. Curie 온도는 Mn 첨가량의 증가와 더불어 감소하였으며, Mn이 0.02 mol% 첨가될 경우, 첨가하지 않은 경우보다 60~$70^{\circ}C$ 감소하였다.

  • PDF

Y/MH의 혼합비가 YMnO$_3$ 세라믹의 소결 및 전기적 특성에 미치는 영향 (The effect of Y/Mn ratio on sintering and electrical properties of YMnO$_3$ ceramics)

  • 김재윤;김부근;김강언;정수태;조상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.657-660
    • /
    • 1999
  • In this paper, we have investigated YMnO$_3$ bulk ceramics, which was made by Mixed oxide method, with Y/Mn ratios of 0.80/1.20, 0.90/1.10, 0.95/1.05, 1.00/1.00, 1.05/0.95 and 1.10/0.90. The samples crystall structure with Y/Mn ratios of 0.95/1.05 was hexagonal structure. The physical properties of YMnO$_3$ ceramics were divided into two groups, the sample with Y/Mn ratios of 0.80/1.20, 0.90/1.10 and 0.95/1.05 is classified to Mn rich sample, and with Y/Mn ratios of 1.00/1.00, 1.05/0.95 and 1.10/0.90 is classified to Y rich sample. The sintering and dielectric properties of this sample were summarized as following sintering density of Mn rich sample was increased. Dissipation factor of Mn rich sample was small The dielectric constant, dissipation factor of sample with Y/Mn ratio (0.90/1.10) were 37, 0.017 respectively at measured 1MHz

  • PDF

고주파 소자용 $BaTi_4O_9$ 박막의 미세구조와 유전특성 연구 (Microstructure and Dielectric Properties of $BaTi_4O_9$ Thin Film for Microwave Devices)

  • 장보윤;이석진;남산;이확주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.125-129
    • /
    • 2004
  • [ $BaTi_4O_9$ ] thin film were grown on $Pt/Ti/SiO_2/Si$ substrate using rf magnetron sputter, and the microstructure and dielectric properties of the thin films were investigated. For the film grown at $350^{\circ}C$ and rapidly thermal annealed at $900^{\circ}C$, the $BaTi_5O_{11}$ Phase was formed. However, the $BaTi_4O_9$ phase was formed when the growing temperature exceeded $450^{\circ}C$ The dielectric constant of the $BaTi_4O_9$ thin film grown at $550^{\circ}C$ and rapidly thermal annealed at $900^{\circ}C$ was about 40 at low frequency range($100kHz{\sim}1MHz$) and 36 at microwave range($1{\sim}10GHz$) which is very close to that of the bulk $BaTi_4O_9$ phase. The dissipation factor was very low, about 0.005 at low frequency as well as microwave range.

  • PDF

DSP를 이용한 주상변압기 유전정접 측정기법 연구 (Research of Tan$\delta$ Measurement on Pole Transformers using DSP)

  • 김재철;이보호;김언석;최도혁;이수길
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권2호
    • /
    • pp.110-118
    • /
    • 1997
  • 본 논문은 DSP를 이용한 주상변압기 유전정접($tan\;delta$) 활선 측정기법을 제안하였다. 변압기 내부에 콘덴서를 삽입한 후 센서에 전압을 인가하고, 인가된 전압과 콘덴서에 흐르는 전류를 측정하여 본 논문에서 제안한 상호 상관 함수 기법을 이용하여 유전정접을 구하였다. 측정의 성능 향상을 위해 TMS320C31 DSP 보드를 사용하였으며 상호 상관 함수 기법을 사용하였다. 또한 노이즈 영향을 검토하기 위해 컴퓨터 시뮬레이션을 수행하였다. 본 연구의 검증을 위해 본 논문에서 구현한 측정장치와 Schering bridge을 사용하여 비고 실험을 하였다. 실험 결과 주상 변압기 절연진단에 충분히 활용할 수 있음을 알 수 있었다.

  • PDF

DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구 (Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP)

  • 이보호;김재철;윤용한;임성정;김언석;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구 (Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP)

  • 이보호;김재철;이수길;윤용한;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF