• Title/Summary/Keyword: dissipation factor

Search Result 394, Processing Time 0.029 seconds

Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings (6.6 kV급 고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kim, Byong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

Microstructure and Varistor Properties of ZVMND Ceramics with Sintering Temperature

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.4
    • /
    • pp.221-225
    • /
    • 2015
  • The sintering effect on the microstructure, electrical properties, and dielectric characteristics of ZnO-V2O5-MnO2-Nb2O5-Dy2O3-based ceramics was investigated. With the increase of sintering temperature from 875 to 950℃, the density of the sintered pellets decreased from 5.57 to 5.45 g/cm3 and the average grain size increased from 4.3 to 10.9 μm. The breakdown field decreased noticeably from 6,095 to 996 V/cm with the increase of sintering temperature. The varistor ceramics sintered at 900℃ exhibited the best nonlinear properties: 39.2 in the nonlinear coefficient and 0.24 mA/cm2 in the leakage current density. The dielectric constant increased sharply from 658.6 to 2,928.8 with the increase of sintering temperature. On the whole, the dissipation factor exhibited a fluctuation with the increase of the sintering temperature, and a minimum value of 0.284 at 900℃.

The Effect on the Dielectric Characteristics of Transformer Oils due to the High Dose Electron Beam (변압기유의 유전특성에 미치는 고조사 전자선의 영향)

  • Cho, Kyung-Soon;Kim, Lee-Doo;Kim, Suk-Wan;Kim, Wang-Kon;So, Byung-Moon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1417-1419
    • /
    • 1997
  • In this paper, the dielectric properties is made researches by the dose of electron beam in order to investigate the electrical properties for transformer oils due to electron beam irradiation. To measure the dielectric loss of irradiated specimen, the liquid electrode of coaxial cylindrical shape is used, and its geometric capacitance is 16 [pF]. And the dielectric dissipation factor, $tan{\delta}$, is measured by using the Video Bridge 2150. The thermal static oven with an automatic temperature controller is used so as to apply specific temperature to specimen. This experiments for measuring the dielectric loss is performed at $20{\sim}120[^{\circ}C]$ in temperature range, $30{\sim}1.5{\times}10^5[Hz]$ in frequency and $300{\sim}500[mV]$ in voltage.

  • PDF

Slender RC columns strengthened with combined CFRP and steel jacket under axial load

  • Lu, Yi-yan;Li, Na;Li, Shan;Ou, Tian-yan
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1077-1094
    • /
    • 2015
  • This paper presents an experimental study on the effectiveness of simultaneous application of carbon fiber-reinforced polymer (CFRP) and steel jacket in strengthening slender reinforced concrete (RC) column. The columns were 200 mm square cross section with lengths ranging from 1600 to 3000 mm. Ten columns were tested under axial load. The effects of the strengthening technique, slenderness ratio, cross-section area of steel angle and CFRP layer number were examined in terms of axial load-axial strain curve, CFRP strain, steel strip strain and steel angle strain. The experiments indicate that strengthening RC columns with combined CFRP and steel jacket is effective in enhancing the load capacity, ductility and energy dissipation capacity of RC column. Based on the existing models for RC columns strengthened with CFRP and with steel jacket, a design formula considering a slenderness reduction factor is proposed to predict the load capacity of the RC columns strengthened with combined CFRP and steel jacket. The predictions agree well with the experimental results.

A Numerical Study on the Transmission of Thermo-Acoustic Wave Induced by Step Pulsed Heating in an Enclosure (제한공간내 펄스가열에 기인한 열음향파의 전달특성에 관한 수치적 연구)

  • 황인주;김윤제
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.914-922
    • /
    • 2002
  • Thermo-acoustic waves can be thermally generated in a compressible flow field by rapid heating and cooling, and chemical reaction near the boundary walls. This mechanism is very important in the space environment in which natural convection does not exist. Also this may be a significant factor for heat transfer when the fluids are close to the thermodynamic critical point. In this study, the generation and transmission characteristics of thermo-acoustic waves in an air-filled confined domain with two-step pulsed heating are studied numerically. The governing equations are discretized using control volume method, and are solved using PISO algorithm and second-order upwind scheme. For the purpose of stable solution, time step was set to the order of $1\times10_-9s,\;and\;grids\;are\;50\times2000$. Results show that temperature and pressure distributions of fluid near the boundary wall subjected to a rapid heating are increased abruptly, and the induced thermo-acoustic wave propagates through the fluid until it decays due to viscous and heat dissipation. Pressure waves have sharp front shape and decay with a long tail in the case of step heating, but these waves have sharp pin shape in the case of pulsed heating.

Effect of Cooling Rate on DC Accelerated Aging Characteristics of ZPCCY-Based Varistor Ceramics (ZPCCY계 바리스터 세라믹스의 DC 가속열화 특성에 미치는 냉각속도의 영향)

  • 남춘우;김향숙
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.776-782
    • /
    • 2002
  • The microstructure, V-Ι characteristics, and stability of ZnO-P $r_{6}$ $O_{11}$ CoO-C $r_2$ $O_3$- $Y_2$ $O_3$-based varistor ceramics were investigated with cooling rate in the range of 2~8$^{\circ}C$/min. The cooling rate relatively weakly affected the microstructure, the varistor voltage, and the leakage current in the V-Ι characteristics. But the nonlinear exponent relatively strongly affected by cooling rate. The cooling rate also greatly affected the stability of V-Ιand dielectric characteristics for DC accelerated aging stress. On the whole, the varistors cooled with 4$^{\circ}C$/fin exhibited the highest performance in the densification, nonlinearity, and stability. Especially, they exhibited a high stability, in which the variation rate of the varistor voltage( $V_{1㎃}$), the nonlinear exponent($\alpha$), and the dissipation factor(tan $\delta$) is -1.4%, -4.9%, and +60.0%, respectively, under DC accelerated aging stress such as 0.95 $V_{1㎃}$15$0^{\circ}C$/12 h)

Investigation of Heat Transfer in Microchannel with One-Side Heating Condition Using Numerical Analysis (수치 해석을 이용한 단일 마이크로채널의 단면 가열 조건의 열전달 특성에 관한 연구)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.986-993
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method far high density electronic devices. The cross-sectional shape of MEMS based microchannel heat sink is limited to triangular, trapezoidal, and rectangular due to their fabrication method. And heat is added to one side surface of heat source. Therefore, those specific conditions make some complexity of heat transfer in microchannel heat sink. Though many previous research of conjugate heat transfer in microchannel was conducted, most of them did not consider heat loss. In this study, numerical investigation of conjugate heat transfer in rectangular microchannel was conducted. The method of heat loss evaluation was verified numerically. Heat distribution was different for each wall of rectangular microchannel due to thermal conductivity and distance from heat source. However, the ratio of heat from each channel wall was correlated. Therefore, the effective area correction factor could be proposed to evaluate accurate heat flux in one side heating condition.

Real-time hybrid testing using model-based delay compensation

  • Carrion, Juan E.;Spencer, B.F. Jr.
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.809-828
    • /
    • 2008
  • Real-time hybrid testing is an attractive method to evaluate the response of structures under earthquake loads. The method is a variation of the pseudodynamic testing technique in which the experiment is executed in real time, thus allowing investigation of structural systems with time-dependent components. Real-time hybrid testing is challenging because it requires performance of all calculations, application of displacements, and acquisition of measured forces, within a very small increment of time. Furthermore, unless appropriate compensation for time delays and actuator time lag is implemented, stability problems are likely to occur during the experiment. This paper presents an approach for real-time hybrid testing in which time delay/lag compensation is implemented using model-based response prediction. The efficacy of the proposed strategy is verified by conducting substructure real-time hybrid testing of a steel frame under earthquake loads. For the initial set of experiments, a specimen with linear-elastic behavior is used. Experimental results agree well with the analytical solution and show that the proposed approach and testing system are capable of achieving a time-scale expansion factor of one (i.e., real time). Additionally, the proposed method allows accurate testing of structures with larger frequencies than when using conventional time delay compensation methods, thus extending the capabilities of the real-time hybrid testing technique. The method is then used to test a structure with a rate-dependent energy dissipation device, a magnetorheological damper. Results show good agreement with the predicted responses, demonstrating the effectiveness of the method to test rate-dependent components.

Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor (고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

Heat Dissipation Analysis of High Voltage Diode Package for Microwave oven (전자레인지용 고압다이오드의 방열특성)

  • Kim, Sang-Cheol;Kim, Nam-Kyun;Bahng, Wook;Seo, Gil-Soo;Moon, Seoung-Ju;Oh, Bang-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.205-208
    • /
    • 2001
  • Steady state and transient thermal analysis has been done by a finite element method in a diode of 12kV blocking voltage for microwave oven. The diode was fabricated by soldering ten pieces of 1200V diodes in series, capping a dummy wafer at the far end of diode series, and finally copper wire bonded for building anode and cathode terminal. In order to achieve high voltage and reliability, the edge of each diode was beveled and passivated by resin and epoxy with a thickness of 25$\mu\textrm{m}$ and 3,700$\mu\textrm{m}$, respectively. The chip size, thickness and material properties were very important factor for high voltage diode package. And also, thermal stress value was highest in the edge of diode and solder. So, design of edge in silicon was very important to thermal stress.

  • PDF