• 제목/요약/키워드: displacement of structure

검색결과 2,248건 처리시간 0.031초

Study on response of a new double story isolated structure under earthquakes

  • Hang Shan;Dewen Liu;Zhiang Li;Fusong Peng;Tiange Zhao;Yiran Huo;Kai Liu;Min Lei
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.17-29
    • /
    • 2024
  • The traditional double story isolated structure is a derivative of the base isolated and inter-story isolated structures, while the new double story isolated structure represents a novel variation derived from the traditional double story isolated structure. In order to investigate the seismic response of the new double story isolated structure, a comprehensive structural model was developed. Concurrently, models for the basic fixed, base isolated, inter-story isolated, and traditional double story isolated structures were also established for comparative analysis. The nonlinear dynamic time-history response of the new double story isolated structure under rare earthquake excitations was analyzed. The findings of the study reveal that, in comparison to the basic fixed structure, the new double story isolated structure exhibits superior performance across all evaluated aspects. Furthermore, when compared to the base isolated and inter-story isolated structures, the new double story isolated structure demonstrates significant reductions in inter-story shear force, top acceleration, and inter-frame displacement. The horizontal displacement of the new double story isolated structure is primarily localized within the two isolation layers, effectively dissipating the majority of input seismic energy. In contrast to the traditional double story isolated structure, the new design minimizes displacements within the inter-isolation layer situated in the central part of the frame, as well as mitigates the overturning forces acting on the lower frame column. Consequently, this design ensures the structural integrity of the core tube, thereby preventing potential collapse and structural damage.

악관절 관절원판 위치변화가 관절원판 형태 및 골변화에 미치는 영향 (Effect of disc displacement on the bony change and disc configuration of TMJ)

  • 김진화;이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.17-24
    • /
    • 2006
  • Purpose : The objective of this study was to investigate the effect of TMJ disc displacement on the TMJ disc configuration and surrounding osseous structure. Materials and Methods : The proton density and 72-weighted MR images of 57 TMJs were retrospectively studied. These TMJs were divided into three groups according to the anterior disc displacement status on MR sagittal images, those were the normal, anterior disc displacement with reduction (ADWR), anterior disc displacement without reduction (ADWOR). The frequency of disc configuration and surrounding bony change, the border status between articular disc and retrodiscal tissue were investigated according to the positional change of articular disc. Results : There were significant statistical differences of chi-square statistics of TMJ disc configurational type between normal and ADWR/ADWOR group, respectively. Surrounding bony change frequently appeared in ADWOR and a statistically significant difference of chi-square statistics of bony change frequency between normal and ADWOR group was observed. Conclusion : These results suggested that the disc configuration and bony change of TMJ are strongly related to TMJ disc displacement.

  • PDF

현장계측과 수치해석에 의한 흙막이구조물의 거동 비교분석 (A Study on Behavior of the Earth Retaining Structure by Field Measurement and Numerical Analysis)

  • Wo, Jongtae
    • 한국재난정보학회 논문집
    • /
    • 제13권3호
    • /
    • pp.286-295
    • /
    • 2017
  • 본 연구는 경사계에 의한 지중수평변위 계측값을 중심으로 수치해석에 적용하기 위한 지반 반력계수를 다양한 이론 및 경험식으로 산출하여 비교하였다. 산정된 지반반력계수의 변화에 따라 벽체 최상단에서는 벽체변위의 최소값과 최대값의 차이가 6.80배로 크게 났으나, 최대 변위점에서는 차이는 거의 없는 1.06배로 나타나 지반반력계수의 증분에 비해 변위의 차이는 작으며 전체적으로 비슷한 값을 나타내었다. 또한 최대변위 발생점에서의 변위를 수치해석한 결과와 계측치로 비교한 결과 변위형상은 비슷하게 나타났다.

Ductility-based seismic design of precast concrete large panel buildings

  • Astarlioglu, Serdar;Memari, Ali M.;Scanlon, Andrew
    • Structural Engineering and Mechanics
    • /
    • 제10권4호
    • /
    • pp.405-426
    • /
    • 2000
  • Two approximate methods based on mechanism analysis suitable for seismic assessment/design of structural concrete are reviewed. The methods involve use of equal energy concept or equal displacement concept along with appropriate patterns of inelastic deformations to relate structure's maximum lateral displacement to member and plastic deformations. One of these methods (Clough's method), defined here as a ductility-based approach, is examined in detail and a modification for its improvement is suggested. The modification is based on estimation of maximum inelastic displacement using inelastic design response spectra (IDRS) as an alternative to using equal energy concept. The IDRS for demand displacement ductilities are developed for a single degree of freedom model subjected to several accelerograms as functions of response modification factor (R), damping ratios, and strain hardening. The suggested revised methodology involves estimation of R as the ratio of elastic strength demand to code level demand, and determination of design base shear using $R_{design}{\leq}R$ and maximum displacement, determination of plastic displacement using IDRS and subsequent local plastic deformations. The methodology is demonstrated for the case of a 10-story precast wall panel building.

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제29권2호
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

Dynamic and static structural displacement measurement using backscattering DC coupled radar

  • Guan, Shanyue;Rice, Jennifer A.;Li, Changzhi;Li, Yiran;Wang, Guochao
    • Smart Structures and Systems
    • /
    • 제16권3호
    • /
    • pp.521-535
    • /
    • 2015
  • Vibration-based monitoring is one approach used to perform structural condition assessment. By measuring structural response, such as displacement, dynamic characteristics of a structure may be estimated. Often, the primary dynamic responses in civil structures are below 5 Hz, making accurate low frequency measurement critical for successful dynamic characterization. In addition, static deflection measurements are useful for structural capacity and load rating assessments. This paper presents a DC coupled continuous wave radar to accurately detect both dynamic and static displacement. This low-cost radar sensor provides displacement measurements within a compact, wireless unit appropriate for a range of structural monitoring applications. The hardware components and operating mechanism of the radar are introduced and a series of laboratory experiments are presented to assess the performance characteristics of the radar. The laboratory and field experiments investigate the effect of factors such as target distance, motion amplitude, and motion frequency on the radar's measurement accuracy. The results demonstrate that the radar is capable of both static and dynamic displacement measurements with sub-millimeter accuracy, making it a promising technology for structural health monitoring.

중진지역 건축물의 묻힌온통기초에 작용하는 토압과 말 뚝변위에 대한 지진해석 (Seismic Analyses of Soil Pressure against Embedded Mat Foundation and Pile Displacements for a Building in Moderate Seismic Area)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.69-76
    • /
    • 2017
  • Seismic analyses of a pile under a large rigid basement foundation embedded in the homogeneous soil layer were performed practically by a response displacement method assuming a sinusoidal wave form. However, it is hard to take into account the characteristics of a large mat foundation and a heterogeneous soil layer with the response displacement method. The response displacement method is relevant to the 2D problems for longitudinal structures such as tunnel, underground cave structure, etc., but might not be relevant with isolated foundations for building structures. In this study, seismic pile analysis by a pseudo 3D finite element method was carried out to compare numerical results with results of the response displacement method considering 3D characteristics of a foundation-soil system which is important for the building foundation analyses. Study results show that seismic analyses results of a response displacement method are similar to those of a pseudo 3D numerical method for stiff and dense soil layers, but they are too conservative for a soft soil layer inducing large soil pressures on the foundation wall and large pile displacements due to ignored foundation rigidity and resistance.

공기예열기를 위한 고온용 변위센서 및 센서드라이브 시스템 구현 (The Implementation of high temperature displacement sensors and sensors drive system for Air-preheater)

  • 조항덕;김우식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.453-458
    • /
    • 2011
  • Air preheater uses the waste heat of the gas which burnt from the boiler from the thermal power plant. Air preheater it is established in the exit of the boiler follows in change of temperature combustion gas and the vibration which it follows in thermal expansion and contraction occurs. Air preheater with ruse the gas the seal the place where it includes a gap in the structure which it does, the vibration which it follows in change of temperature fluctuates the displacement of gap, fluctuation of the leakage quantity which occurs from gap there is a possibility of decreasing an effect to system. Part system it will be able to control the interval of gap in order, control mechanism about under establishing the place where it does the gap control actively, measures a gap the displacement sensor for is necessary. Like this displacement sensor the condition must do continuous running from atmosphere of high temperature was demanded all. This paper investigates the implementation instance of hazard existing which implement the high temperature displacement sensor, it analyzes, produces the result which it examines a model, it was a presentation. These results with the fact that it will contribute in the research for the implementation and a localization of the high temperature displacement sensor and advanced air preheater.

  • PDF

Displacement estimation of bridge structures using data fusion of acceleration and strain measurement incorporating finite element model

  • Cho, Soojin;Yun, Chung-Bang;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.645-663
    • /
    • 2015
  • Recently, an indirect displacement estimation method using data fusion of acceleration and strain (i.e., acceleration-strain-based method) has been developed. Though the method showed good performance on beam-like structures, it has inherent limitation in applying to more general types of bridges that may have complex shapes, because it uses assumed analytical (sinusoidal) mode shapes to map the measured strain into displacement. This paper proposes an improved displacement estimation method that can be applied to more general types of bridges by building the mapping using the finite element model of the structure rather than using the assumed sinusoidal mode shapes. The performance of the proposed method is evaluated by numerical simulations on a deck arch bridge model and a three-span truss bridge model whose mode shapes are difficult to express as analytical functions. The displacements are estimated by acceleration-based method, strain-based method, acceleration-strain-based method, and the improved method. Then the results are compared with the exact displacement. An experimental validation is also carried out on a prestressed concrete girder bridge. The proposed method is found to provide the best estimate for dynamic displacements in the comparison, showing good agreement with the measurements as well.

시그모이드 함수를 이용한 다중 계측데이터 모니터링 시스템 (Multimetric Measurement Data Monitoring System Using Sigmoid Function)

  • 송정호;신준우;한희수
    • 지질공학
    • /
    • 제33권1호
    • /
    • pp.137-149
    • /
    • 2023
  • 구조물에 작용하는 토압의 방향과 장기변위상태변화를 직관적으로 파악하기 위해 수평, 수직방향의 변위 데이터를 시그모이드 함수를 이용하여 가공하고 각각 좌표계의 한 축으로 하여 변위좌표계 시스템을 설정하였다. 이러한 변위좌표계에 변위상태(압축 또는 팽창) 구분영역과 관리단계 구분영역 설정하여 각 계측지점의 변위상태와 관리단계를 직관적으로 확인할 수 있었다. 관측점을 연속적으로 나타내어 변위경로를 나타내었으며, 변위경로를 통해 변위이력, 변위추세, 지반에 작용하는 응력방향 등을 알 수 있었다. 흙막이 가시설의 실계측데이터 분석 결과 모든 계측지점에서 응력해방 방향으로 변위가 일어났으며, 정상관리상태에 위치하였다. 또한 공간적 상관성이 높은 계측지점 간 거동은 비슷한 거동추세를 보였으며, 공간적 상관성이 낮은 계측지점 간에는 상이한 거동 추세를 보였다. 공간적으로 연속되어 분포하는 지표침하데이터를 변위좌표계를 이용하여 전조현상과 거동영역에 대한 상관성 분석을 수행하면 파괴시간, 영역 예측이 가능 할 것으로 판단된다.