• Title/Summary/Keyword: displacement fields

Search Result 345, Processing Time 0.026 seconds

Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer (소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토)

  • Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyung;Wu Hong Gyun;Kim Dae Yong;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 1998
  • Purpose : This study is to evaluate the efficacy of small bowel displacement system(SBDS) in post-operative pelvic radiation therapy(RT) of rectal cancer patients by measurement of small bowel volume included in the radiation fields receiving therapeutic dose. Materials and Method : Ten consecutive new rectal cancer patients referred to the department of Radiation Oncology of Samsung Medical Center in May of 1997 were included in this study. All patients were asked to drink $Castrographin^(R)$ before simulation and were laid prone for conventional simulation and CT scans with and without SBDS. The volume of opacified small bowel on CT scans, which was to be included in the radiation fields receiving therapeutic dose, was measured using Picture archiving and communication system (PACS). Results : The average small bowel volumes with and without SBDS were 176.0ml(5.2-415.6ml) and 185.1ml(54.5-434.2ml), respectively The changes of small bowel volume with SBDS compared to those without SBDS were more than $10\%$ decrease in three, less than 10% decrease in two, less than $10\%$ increase in three, and more than $10\%$ increase in two patients. Conclusion : No significant advantage of using SBDS in post-operative pelvic RT for rectal cancer patients has been shown by small bowel volume measurement using CT scan considering additional effort and time needed for simulation and treatment setup.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system (컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구)

  • Lee, Kang-nam;Lee, Byeong-chun;Kim, Jung-tae;Park, Jong-im;Shin, Tae-young;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF

Effectiveness of Bellyboard Device for Displacement of Small Bowel in Pelvic Irradiation (골반 방사선치료 시 소장의 위치변화를 위한 벨리보드의 유용성)

  • Lee, Rena;Lee, Kyung-Ja;Suh, Hyunsuk
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.202-208
    • /
    • 2007
  • Various techniques were evaluated to determine the best method for reducing small bowel involvement in pelvic irradiation. Fourteen patients receiving radiation in pelvic area were enrolled for this study. Five sets of small bowel images were obtained. Patients were positioned on a simulation couch with full bladder in prone and supine positions and 2 sets of images were taken. Then they were asked to empty their bladder and 2 sets of images were taken in prone and supine positions. A belly board device (BBD) was placed and one set of images was obtained. Using a software, the area of small bowel inside treatment field was contoured, measured, and analyzed. In both full and empty bladder cases, small bowel area reduction was observed in prone position as compared to supine position. Especially statistically significant reduction is noted in lateral film. An average decreases of 13% in PA and 26% in lateral direction were noted with bladder distention as compared to empty bladder. With the use of BBD for empty bladder, a significant reduction of $62.8{\pm}27.1%$ and $63.1{\pm}32.9%$ in PA and lateral directions were observed as compared to without BBD in prone position, respectively. In conclusion, the best sparing of small bowel concerning the area included in the treatment fields was achieved with BBD in prone position with empty bladder. However, further reduction is expected if the bladder was filled fully because the analysed data with empty vs full bladder study shows increased sparing of small bowel with distended bladder.

  • PDF

Evaluation of Lateral Flow in Soft Ground under Embankment (성토하부 연약지반의 측방유동 평가)

  • Hong, Won-Pyo;Cho, Sam-Deok;Lee, Jae-Ho;Lee, Kwang-Wu
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.93-100
    • /
    • 2006
  • The lateral soil movement in soft grounds undergoing improvement with application of vertical drains is analyzed on the basis of monitoring data at three fields, in which fifty six monitoring sites are located. Based on the investigations, the criterions are suggested to predict the lateral soil movement. In order to predict the lateral soil movement in the improved soft grounds by using the dimensionless parameter R suggested by Marche & Chapuis (1974), it is desirable that the maximum lateral displacement in the soft ground below the toe of embankment should be applied to calculate R instead of the lateral displacement at the toe of embankment. The lateral soil movement may increase rapidly, if the safety factor of slope is less than 1.4 in case of high ratio of H/B (Thickness of soft ground/Embankment width) such as 1.15 or is less than 1.2 in case of low ratio of H/B such as 0.05. Also, the graph suggested by Tschebotarioff (1973), which illustrates the relationship between the maximum height of embankments and the undrained shear strength of soft grounds, can be applied to the evaluation for the possibility of the lateral soil movement due to embankments on soft grounds.

A Numerical Study on the Effect of Steel Casing on Bearing Capacity of Drilled Shafts for Marine Bridges (수치해석을 이용한 국내 해상교량 현장타설말뚝의 강관지지효과)

  • Lee, Juhyung;Shin, Hyu-Soung;Park, Minkyung;Park, Jae Hyun;Kwak, Kiseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3C
    • /
    • pp.149-158
    • /
    • 2008
  • This study is concerned with the characteristics of the behavior of drilled shafts with steel casing, a material that is used for large bridge foundations in Korea, and especially for weak submerged ground conditions. The effect of steel casing on bearing capacity of drilled shafts was also verified in this study. Three large drilled shafts with 1.8, 2.4, 3.0m diameter respectively were selected, and 3-D finite element analysis has been undertaken on the following three models: 1) drilled shafts without steel casing, 2) drilled shafts with steel casing, 3) steel-concrete composite drilled shafts. Interface element between concrete core and steel casing was taken into account, and ground conditions and load combinations were applied which had been considered in the fields. Detailed characteristics of the stress and displacement distributions were evaluated to understand the characteristics of the behavior of the drilled shafts. Based on the study performed, the steel casing used as load-carrying materials in the drilled shafts can reduce the horizontal and vertical displacement of drilled shafts by 32~37% and 15~19% respectively compared with drilled shafts without steel casing.

Accuracy Evaluation of Non-prism Total Station for Topographic Surveying (지형측량을 위한 무 프리즘 토털스테이션 정확도 평가)

  • Seo, Dong-Ju
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.5
    • /
    • pp.433-441
    • /
    • 2006
  • With a development of electrical technology in recent, it is possible to measure distance without direct contact to object using laser which launched at instrument and reflect from object. Furthermore, the advent of non prism total station brought the increment of application in many fields including not only road, airport, and harbors but also measurement and monitoring of structural displacement in construction fields. In this study, therefore, to evaluate accuracy of non prism total station, accuracy was analyzed by measuring certain distance which classified by both certain materials and angle of reflection. By this method, the derived values were applied to topographical survey for the efficient applicability. According to a study, result value of non prism total station was satisfBctory regardless of material when the angle of reflection was 90 degrees. RMSE increased when the angle of reflection are gradually increased to acute angle. In result of regression analysis using certain distance which classified by both materials and angles of reflection, there is relationship between distance and angle of reflection, but material has no relevance to the result value. When carrying out general topographical survey, proper application of non prism total station will go far conducting safe and prompt survey at the dangerous site such a road which have lots of traffic flow and rock joint which have high angles of inclination.

Improvement of Enhanced Assumed Strain Four-node Finite Element Based on Reissner-Mindlin Plate Theory (개선된 추가변형률 4절점 평판휨 요소)

  • Chun, Kyoung Sik;Park, Dae Yong;Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.295-303
    • /
    • 2004
  • In this paper, an improved four-node Reissner-Mindlin plate-bending element with enhanced assumed strain field is presented for the analysis of isotropic and laminated composite plates. To avoid the shear locking and spurious zero energy modes, the transverse shear behavior is improved by the addition of a new enhanced shear strain based on the incompatible displacement mode approach and bubble function. The "standard" enhanced strain fields (Andelfinger and Ramm, 1993) are also employed to improve the in-plane behaviors of the plate elements. The four-node quadrilateral element derived using the first-order shear deformation theory is designated as "14EASP". Several applications are investigated to assess the features and the performances of the proposed element. The results are compared with other finite element solutions and analytical solutions. Numerical examples show that the element is stable, invariant, passes the patch test, and yields good results especially in highly distorted regimes.

The Change of Interior Orientation Parameters in Zoom Lens Digital Cameras (줌렌즈 디지털 카메라의 내부표정요소 변화)

  • Kim, Gi-Hong;Jeong, Soo;Kim, Baek-Seok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.93-98
    • /
    • 2010
  • Recently, as digital photogrammetry bas been widely used in various fields including construction, it is also being applied to several industries. It is essential for interior orientation to determine accurate focal length of camera, lens distortion, location of principal point in order to apply high quality digital camera to digital photogrammetry. In this study we conducted interior orientation for zoom lens camera with regular time and zoom factors and analyzed change of radial distortion parameters and location of principal point to evaluate interior orientation stability. As a result, radial distortion parameters($k_1,k_2$) are converged into zero by increasing zoom factors. There are correlation between the change of location of point and zoom factors. The displacement of $x_p$, $y_p$ increase as zoom factors rise high.

Free vibration analysis of functionally graded plates with temperature-dependent properties using various four variable refined plate theories

  • Attia, Amina;Tounsi, Abdelouahed;Bedia, E.A. Adda;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • v.18 no.1
    • /
    • pp.187-212
    • /
    • 2015
  • In this paper, various four variable refined plate theories are presented to analyze vibration of temperature-dependent functionally graded (FG) plates. By dividing the transverse displacement into bending and shear parts, the number of unknowns and governing equations for the present model is reduced, significantly facilitating engineering analysis. These theories account for parabolic, sinusoidal, hyperbolic, and exponential distributions of the transverse shear strains and satisfy the zero traction boundary conditions on the surfaces of the plate without using shear correction factors. Power law material properties and linear steady-state thermal loads are assumed to be graded along the thickness. Uniform, linear, nonlinear and sinusoidal thermal conditions are imposed at the upper and lower surface for simply supported FG plates. Equations of motion are derived from Hamilton's principle. Analytical solutions for the free vibration analysis are obtained based on Fourier series that satisfy the boundary conditions (Navier's method). Non-dimensional results are compared for temperature-dependent and temperature-independent FG plates and validated with known results in the literature. Numerical investigation is conducted to show the effect of material composition, plate geometry, and temperature fields on the vibration characteristics. It can be concluded that the present theories are not only accurate but also simple in predicting the free vibration responses of temperature-dependent FG plates.