• Title/Summary/Keyword: disk-type

Search Result 928, Processing Time 0.026 seconds

A Cache buffer and Read Request-aware Request Scheduling Method for NAND flash-based Solid-state Disks (캐시 버퍼와 읽기 요청을 고려한 낸드 플래시 기반 솔리드 스테이트 디스크의 요청 스케줄링 기법)

  • Bang, Kwanhu;Park, Sang-Hoon;Lee, Hyuk-Jun;Chung, Eui-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.143-150
    • /
    • 2013
  • Solid-state disks (SSDs) have been widely used by high-performance personal computers or servers due to its good characteristics and performance. The NAND flash-based SSDs, which take large portion of the whole NAND flash market, are the major type of SSDs. They usually integrate a cache buffer which is built from DRAM and uses the write-back policy for better performance. Unfortunately, the policy makes existing scheduling methods less effective at the I/F level of SSDs Therefore, in this paper, we propose a scheduling method for the I/F with consideration of the cache buffer. The proposed method considers the hit/miss status of cache buffer and gives higher priority to the read requests. As a result, the requests whose data is hit on the cache buffer can be handled in advance and the read requests which have larger effects on the whole system performance than write requests experience shorter latency. The experimental results show that the proposed scheduling method improves read latency by 26%.

Humidity Dependence of Tribological Behavior of DLC Films (DLC 필름의 마찰마모 특성의 습도 의존성에 대한 연구)

  • Park, Se-Jun;Lee, Kwang-Ryeol;Lee, Seung-Cheol;Ko, Dae-Hong
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.287-293
    • /
    • 2006
  • Diamond-like carbon (DLC) film was deposited using benzene $(C_6H_6)$ by r. f-plasma assisted chemical vapor deposition. The tribological properties of the DLC film were tested by rotating ball-on-disc type tribometer isolated by a chamber. The tribological test was performed in air environment of relative humidity ranging from 0 to 90% in order to observe the tribological behavior of the DLC film with the change of humidity. We used steel ball and DLC coated steel ball to investigate the effect of the counterface material. Using steel ball, the friction coefficient of DLC film increased from 0.025 to 0.2 as the humidity increased from 0% to 90%. In case of DLC coated steel ball which didn't form the Fe-rich debris, the friction coefficient showed much lower dependence of humidity as 0.08 in relative humidity 90%. We confirmed that the high humidity dependence of the friction coefficient using steel ball resulted from the increase of debris size with humidity and the formation of Fe-rich debris by the wear of steel ball. And the friction coefficient was immediately dropped when the relative humidity changed from 90% to 0% during test using steel ball. From this result, we confirmed that the effect of the Fe-rich debris on the friction coefficient was that Fe element in debris formed the highly sensitive graphitic transfer layer to humidity.

Friction and Wear Behavior of Ultra-Thin TiN Film during Sliding Wear against Alumina and Hardened Steel (마모 상대재 변화에 따른 TiN 극박막의 마찰 및 마모거동)

  • Song, Myeong-Hun;Lee, Jae-Gap;Kim, Yong-Seok
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.62-68
    • /
    • 2000
  • Ultra thin TiN films (50∼700nm thickness) were deposited on AISI 304 stainless steel substrates using a reactive DC magnetron sputtering deposition process to investigate their wear and friction properties. Dry sliding wear tests of the films were carried out against hardened steel and alumina counterparts using a pin-on-disk type wear tester at room temperature. Variation of friction coefficient was measured as a function of film thickness, load, sliding speed and roughness of the substrate. Worn surfaces of the film were examined by a scanning electron microscope. Wear resistance of the TiN film increased with the increase of the film thickness. The TiN film showed relatively high wear resistance in spite of its ultra thin thickness when it is mated by the steel counterpart, while it showed poor wear resistance with the alumina counterpart. The good wear resistance with the steel counterpart was explained by the formation of oxide layers on the film surface and sound interface character between the ultra thin film and the substrate.

  • PDF

A Development of Stem Analysis Program and its Comparison with other Method for Increment Calculation (수간석해(樹幹析解) 전산(電算)프로그램 개발(開發) 및 생장량(生長量) 계산방법(計算方法)의 비교(比較)에 관(關)한 연구(硏究))

  • Byun, Woo Hyuk;Lee, Woo Kyun;Yun, Kwang Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.1
    • /
    • pp.1-15
    • /
    • 1990
  • In this study the stem analysis program, which can be operated with personal computer was developed to reduce time and cost of calculation, and to increase accuracy of analysis. The stem analysis method used in this program was compared with other methods. The results obtained were as follows : The value, 1/100mm measured from the latest annual ring measurement machine (Jahrringme${\beta}$geraete Johan Type II) was automatically inputed to the computer and saved into given file name. Turbo Pascal program was written to do this. The measured data was analyzed by stem analysis calculation program written by Fortran-77. Volume and height increments were approximated by spline function, and diameter of the stem disk was calculated by quadratic mean method. The increment values calculated by the programs were printed annually and in every five-year. Stem analysis diagram and several increment graphs were also easily printed. The result compared between those analysis methods showed that quadratic mean could reduce the error caused from eccentric pith. When the stem taper curve method, approximated by spline function, was used in the calculation of tree height and volume, increments would be more exactly calculated.

  • PDF

R.F. plasma assisted CVD로 합성한 BN, BCN 박막의 물성과 구조 연구

  • 김홍석;백영준;최인훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.114-114
    • /
    • 1999
  • Boron nitride (BN)는 매우 뛰어난 물리적, 화학적 성질을 가지고 있는 재료로 많은 연구가 진행되고 있다. hexagonal 형태의 hBN의 경우 큰 전기 저항과 열 전도도를 가지고 있고 열적 안정성을 가지고 있어 반도체 소자에서 절연층으로 쓰일 수 있다. 또한 X-ray와 가시광선을 투과시키기 때문에 X-ray와 가시광선을 투과시키기 때문에 X-ray lithography이 mask 기판으로 사용될 수 있다. Boron-carbon-nitrogen (BCN) 역시 뛰어난 기계적 성질과 투명성을 가지고 있어 보호 코팅이나 X-ray lithography에 이용될 수 있다. 또한 원자 조성이나 구성을 변화시켜 band gap을 조절할 수 있는 가능성을 가지고 있기 때문에 전기, 광소자의 재료로 이용될 수 있다. 본 연구에서는 여러 합성 조건 변화에 따른 hBN 막의 합성 거동을 관찰하고, 카본 농도변화에 따른 BCN 막의 기계적 성질과 구조의 변화, 그리고 실리콘 첨가에 의한 물성 변화를 관찰하였다. BN박막은 실리콘 (100) 기판 위에 r.f. plasma assisted CVD를 이용하여 합성하였다. 합성 압력 0.015 torr, 원료 가스로 BCl3 1.5 sccm, NH3 6sccm을 Ar 15 sccm을 사용하여 기판 bias (-300~-700V)와 합성온도 (상온~50$0^{\circ}C$)를 변화시켜 BN막을 합성하였다. BCN 박막은 상온에서 기판 bias를 -700V로 고정시킨 후 CH4 공급량과 Ar 가스의 첨가 유무를 변화시켜 합성하였다. 또한 SiH4 가스를 이용하여 실리콘을 함유하는 Si-BCN 막을 합성하였다. 합성된 BN 막의 경우, 기판 bias와 합성 온도가 증가할수록 증착속도는 감소하는 경향을 보여 주었다. 기판 bias와 합성온도에 따른 구조 변화를 SEM과 Xray로 분석하였다. 상온에서 합성한 경우는 표면형상이 비정질 형태를 나타내었고, X-ray peak이 거의 관찰되지 않았다. 합성온도가 증가하게 되면 hBN (100) peak이 나타나게 되고 이것은 합성된 막이 turbostratic BN (tBN) 형태를 가지고 있다는 것을 나타낸다. 50$0^{\circ}C$의 합성 온도에서 기판 bias가 -300V에서 hBN (002) peak이 관찰되었고, -500, -700 V에서는 hBN (100) peak만이 관찰되었다. 따라서 고온에서의 큰 ion bombardment는 합성되는 막의 결정성을 저해하는 요소로 작용한다는 것을 확인 할 수 있었다. 합성된 BN 막은 ball on disk type의 tribometer를 이용하여 마모 거동을 관찰한 결과 대부분 1이상의 매우 큰 friction coefficient를 나타내었고, nano-indenter로 측정한 BN막의 hardness는 매우 soft한 막에서부터 10 GPa 정도 까지의 값을 나타내었고, nano-indenter로 측정한 BN 막의 hardness는 매우 soft한 막에서부터 10GPa 정도 까지의 값을 가지며 변하였다. 합성된 BCN, Si-BCN 막은 FT-IR, Raman, S-ray, TEM 분석을 통하여 그 구조와 합성된 상에 관하여 분석하였다. FT-IR 분석을 통해 B-N 결합과 C-N 결합을 확인할 수 있었고, Raman 분석을 통하여 DLC의 특성을 분석하였다. 마모 거동에서는 BCN 막의 경우 0.6~0.8 정도의 friction coefficient를 나타내었고 Si-BCN 막은 0.3이하의 낮은 friction coefficient를 나타내었다. Hardness는 carbon의 함유량과 Ar 가스의 첨가 유무에 따라 각각을 측정하였고 이것은 BN 막 보다 향상된 값을 나타내었다.

  • PDF

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

A STUDY ON THE EFFECT OF BASE MATERIALS TO PROTECT THE CERVICAL LEAKAGE OF BLEACHING AGENTS (표백제의 치경부 누출을 방지하기 위한 각종 이장재의 효과에 관한 연구)

  • Song, Byeong-Choon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.585-601
    • /
    • 1994
  • The purpose of this study was to evaluate the ability of several intracoronal base materials to prevent cervical leakage of a bleaching agent into the dentinal tubules and along the root canal. In this study, thirty-two anterior teeth were used. After lingual access was prepared in each tooth, tooth was instrumented with a step-back technique to a Nos. 40-50 using K-type files. All teeth were obturated with a lateral condensation technique. Excess gutta percha was removed with a warm instrument to the facial level of the CEJ. Teeth were divided into four groups : Teeth in control group were not filled with base material. Teeth in groups 1, 2, and 3 had 2mm of gutta percha removed with a warm instrument, then Dycal, Fuki II LC and Z-100 were filled with palstic instruments on the top of the gutta percha respectively. All teeth were bleached for 7 days, fresh bleach was added for another 7 days, then a 10 % methylene blue dye was placed inside the access preparation. They were stored at $37^{\circ}C$ and $100^{\circ}C$ humidity for 5 days. Each tooth was sectioned perpendicular to the long axis using a diamond disk. Initial cuts were made at the most coronal level of facial and lingual CEJ's, then another cuts continued appically in the levels of 0.5mm, 1.5mm, and 2.0mm respectively. The amount of dye leakage through the dentinal tubules was determined at each cut section. In addition, when the cut specimen was determined to be last penetration of any dye, this level was recorded as depth of apical leakage from the coronal terminus of the gutta percha, Dycal, Fuji II LC and Z-100. The acquired data were analyzed by Tukey's Multiple Range Test adn Cochran-Mantel-Haenszel Test to see if there was any statistically significant difference in dye penetration and linear apical leakage among the groups. The results were as follows : 1. Control group at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 AND 3 at level of 2.0mm showed the least dye penetration through the facial or lingual dentinal tubules, but there were no significant difference among three groups. 2. Group 2 at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 and 3 at level of 2.0mm showed the least dye penetration through the proximal dentinal tubules, but there were no significant difference among control group, group 2, and group 3. 3. Group 1 showed the greatest dye penetration through the facial or lingual and proximal dentinal tubules at all levels, and there were significant difference with other three groups. 4. Control group and group 1 showed 2mm apical dye leakage at facial or lingual and proximal aspects, group 2 showed 1.5mm, and group 3 showed 0.5mm.

  • PDF

Distribution of Antimicrobial Resistant Genes in Acinetobacter calcoaceticus-baumannii Complex Isolated from Clinical Specimens in Chungcheong, Korea (충청지역의 임상검체로부터 분리된 Acinetobacter calcoaceticus-baumannii Complex를 대상으로 항균제 내성 유전자 비교분석)

  • Sung, Ji Youn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.427-434
    • /
    • 2017
  • Species that belong to the Acinetobacter calcoaceticus-baumannii (Acb) complex are major causes of hospital-acquired infections. They are important opportunistic pathogens. These species are usually multidrug resistant (MDR), and the therapeutic options to treat the infections caused by these species are limited. In the present study, we investigated fluoroquinolone resistance mechanisms in 53 ciprofloxacin resistant Acinetobacter species isolates in Chungcheong, Korea. Antimicrobial susceptibilities were determined using the disk-diffusion method. Detections of genes and identification of mutations associated with fluoroquinolone resistance were carried out using PCR and DNA sequencing. In our study, 47 out of 53 ciprofloxacin resistant Acinetobacter isolates harbored sense mutations at the 83rd residue (serine to leucine) in the gyrA gene as well as at the 80th residue (serine to leucine) in the parC gene. Among the 47 isolates harboring sense mutations in gyrA and parC gene, 44 isolates were A. baumannii and 3 isolates were A. pittii. Plasmid-mediated quinolone resistance (PMQR) determinants were detected in isolates in our study. Among the 46 ciprofloxacin resistant A. baumannii isolates, 41 showed type A, B, or F banding patterns on their REP-PCR profiles. This result suggests that clonal relation and horizontal spreading of the bacterial isolates have been around hospitals in Chungcheong area. To prevent colonization and disseminations of fluoroquinolone resistance Acb complex isolates, continuous investigation and monitoring of antimicrobial resistant determinants of MDR isolates are needed.

Si 함유 다이아몬드상 카본 필름의 환경 변화에 따른 마찰거동 연구

  • 박세준;이광렬;공호성;양승호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.126-126
    • /
    • 2000
  • 다이아몬드상 카본(DLC) 필름은 경도가 높고, 마찰계수가 낮다는 장점을 가지고 있기 때문에 내마모성 코팅이나 윤활성코팅에 응용을 위한 연구가 활발히 진행중이다. 하지만 마찰계수가 주변환경에 매우 큰 영향을 받는다는 단점이 있다. 이러한 단점은 DLC필름의 응용에 대한 저해 요인이 되며, 이 점을 보완하기 위해서 DLC 필름에 Si을 첨가하는 연구들이 진행되고 있다. 본 실험에서는 r.f-PACVD 법을 이용하여 Si이 첨가된 DLC 필름의 주위 환경 변화에 따른 마찰특성의 변화를 연구하였다. 사용한 반응 가스는 벤젠(C6H)과 희석된 Silane(SiH4 : H2 = 10 : 90)이며, 희석된 Silane과 벤젠의 첨가비율을 조절하여 필름내 Si의 함량을 조절하였고, 증착시 바이아스의 전압은 -400V로 하였다. 마찰테스트는 Ball-on-Disk type의 조건에서 대기, 건조공기, 진공의 세가지 분위기에서 마찰테스트를 실행하였다. 실험결과 마찰계수는 건조공기, 대기, 진공의 순으로 증가하였고, 필름내에 포함되어 있는 Si의 양이 증가할수록 마찰계수는 낮고 안정한 값을 나타내었다. Tribochemiacal 분석과, ball과 track의 전자현미경 사진 분석 결과, 진공에 비해서 건조공기와 대기중에서 마찰계수가 낮은 것은 DLC 필름내에 마모 track 중심부에 Si-C-O 계의 화합물이 형성되어, 이 화합물이 마찰계면에 존재하여 마찰계수를 낮추었음을 확인하였다. 그리고 대기중에서 실험한 경우, 습기의 존재로 인해 마모입자가 볼의 표면에서 엉김으로써 건조공기의 상태에서 보다 높은 마찰저항을 갖게 됨으로 인하여 마찰계수가 높아짐을 알 수 있었다.a)는 as-deposit 상태이며, 그림 1(b)는 45$0^{\circ}C$, 60min 열처리한 plan-view TEM 사진이다.dical의 영향을 조사하였으며 oxygen radical의 rf power에 따른 변화는 OES(Optical emission spectroscopy)를 사용하였다. 너무 적은 oxygen ion beam flux나 oxygen radical은 film의 전도도 및 투과도를 저하시켰고 반면 너무 과도한 flux의 증가 시는 전도도는 감소하였고 투과도는 증가하는 경향을 보였다. 기판에 도달하는 oxygen ion flux는 faraday cup을 이용하여 측정하였으며 증착된 ITO film은 XPS, UV-spectrometer, 4-point probe를 이용하여 분석하였다. 때문으로 생각되어진다. 또한, 성장 온도가 낮아짐에 따라 AlGaN의 성장을 저해하기 때문으로 판단된다. 성장 온도 변화에 따라 성장된 V의 구조적 특성 및 표면 거칠기 변화를 관찰하여 AlGaN의 성장 거동을 논의하겠다.034, 0.005 정도로 다시 감소하였다. 박막의 유전율은 약 35 정도의 값을 나타내었으며 X-선 회절 data로부터 분석한 박막의 변형은 증온도에 따라 7.2%에서 0.04%로 감소하였고 이 이경향은 유전손실은 감소경향과 일치하였다.는 현저하게 향상되었다. 그 원인은 SB power의 인가에 의해 활성화된 precursor 분자들이 큰 에너지를 가지고 기판에 유입되어 치밀한 박막이 형성되었기 때문으로 사료된다.을수 있었다.보았다.다.다양한 기능을 가진 신소재 제조에 있다. 또한 경제적인 측면에서도 고부가 가치의 제품

  • PDF

Aerodynamic Characteristics Analysis of Small Two-Stage Turbo Blower Using CFD (CFD를 이용한 소형 2단 터보블로워의 공력해석)

  • Seo, Seungjae;Ryu, Minhyoung;Cho, Leesang;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.326-335
    • /
    • 2014
  • Aerodynamic characteristics of the small two-stage turbo blower were investigated using commercial CFD tool(ANSYS CFX Ver. 14.5) in this paper. Turbo blower, which is a centrifugal type of turbomachinery, is used in various industries. It is used for application that required high static pressure rising at relatively small volumetric flow rate. In order to understand the mechanism of static pressure rising, the aerodynamic characteristics of the small two-stage turbo blower are analyzed at high rotating speed in this study. The k-${\omega}$ SST turbulence model, which is good at prediction of adverse pressure gradient flows, was applied. The CFD results of the turbo blower are validated by performance test. The static pressure rising of the turbo blower is nonlinearly increased over the first stage and the second stage. The secondary flow occurred at guide vanes, between the casing and the first impeller shroud, and the bottom of the impeller disk. As a result, It is required that whole fluid area is analyzed to predict aerodynamic characteristics of small two-stage turbo blower. and the result should be selected with considering for error from experiment and CFD.