• 제목/요약/키워드: disconnection

검색결과 409건 처리시간 0.032초

A Study on the Analysis of the Directional Information Sign to Destinations and Spatial Configuration in the Exhibition Spaces of Museum (박물관 전시부문의 관람객 유도사인과 공간구조)

  • Lim, Che-Zinn;Park, Moo-Ho
    • Korean Institute of Interior Design Journal
    • /
    • 제15권6호
    • /
    • pp.205-212
    • /
    • 2006
  • The premise of this study is that an ultimate objective in planning an exhibition space is spectators' experiences shaped by a result of their first-hand experiences and responses within an exhibition space, and this result can be recognized in the spectators' movement. Thus, the sign system that can directly affects viewers' main line of flow and movement patterns was examined vis--vis a mutually complementary relation in a triangular composition with the structure of exhibition space and the exhibition contents. Based on the findings, predictive values before and after a complementary application of the sign system to the structure of exhibition space was analyzed and its validity was assessed. The results of this research analysis were drawn as follows. It was shown that an understanding of the locations of direction signs and the degree of recognition can function as an important factor to predict viewers' movement, along with an understanding of topological characteristics of an exhibition space. In terms of the connection and disconnection of space units that form the space structure, it suggests that the distribution of signs and the degree of recognition can adjust the degree of connection and disconnection. Even though exhibition spaces for research subjects were selected from a relatively large number of museums, but the research was limited with a focus on the structure of exhibition space and sign systems. Thus, it is proposed that future studies should be conducted by including varieties of exhibition and environmental factors.

Pro-active Routing Selection and Maintenance Algorithms for Mobile Ad Hoc Network Environments (이동 Ad Hoc 네트워크 환경에서 사전 활성화 라우팅 선택과 관리유지 알고리즘)

  • Cho Young-Joo;Chung Il-Yong
    • Journal of Korea Multimedia Society
    • /
    • 제9권5호
    • /
    • pp.606-614
    • /
    • 2006
  • The conventional on-demand mobile ad hoc routing algorithms (DSR and AODV) initiate route discovery only after a path breaks, incurring a significant cost and time in detecting the disconnection and establishing a new route. In this theory, we investigate adding proposed pro-active route selection and maintenance to the conventional on-demand mobile ad hoc routing algorithms(DSR and AODV). The key idea is to be only considered likely to be a path break when the received packet power becomes close to the minimum critical power and to be generated the forewarning packet when the signal power of a received packet drops below a optimal threshold value. After generated the forewarning packet, the source node can initiate rout discovery in advance; potentially avoiding the disconnection altogether. Our extensive simulation study shows that the proposed advance-active route selection and maintenance algorithms outperforms the conventional on-demand routing protocol based on DSR and AODV in terms of packet delivery ratio, packet latency and overhead.

  • PDF

Moderating Effects of Teacher-Child Relationship on the Association Between Temperament and Peer Play Interaction of Young Children (만 4세 유아의 기질이 또래놀이상호작용에 미치는 영향에 대한 교사 유아관계의 조절효과)

  • Shin, Yoo Lim
    • Korean Journal of Child Education & Care
    • /
    • 제19권2호
    • /
    • pp.57-69
    • /
    • 2019
  • Objective: The purpose of this research was to examine the moderating effects of relationships on the association between temperament and peer play interaction. Methods: The participants were 606 four year olds who were recruited from day care centers and preschools located in Incheon and Gyeonggi province. Teacher-child relationship was measured with Student-Teacher Relationship Scale. Peer interactions were measured with Penn Interactive Peer Play Scale. Temperament was measured with Child Behavior Questionnaire (CBQ). The data was analysed using Pearson correlation and hierarchial regression. Results: Teacher-child intimacy moderated the associations between inhibitory control and play disruption as well as between emotionality and play disconnection. Moreover, Teacher-child conflict moderated the association between emotionality and play disconnection. Conclusion/Implications: The findings suggest that teacher-child relationships buffer risks conferred by temperament.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • 제38권3호
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Multi-dimensional Development Type and Plan for Railway Facility Site - Focus on the Gyeongbu Line Railway Multi-Dimensional Project in Busan (철도시설 부지 입체개발 유형 및 개발 방안 - 경부선 철도 입체화 사업을 대상으로 -)

  • Keum, Yun Jeon ;Kim, Jong Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제43권4호
    • /
    • pp.525-533
    • /
    • 2023
  • Due to the topographical characteristics of Busan, which has many mountainous areas, there is a shortage of available land, and even the Gyeongbu Line railroad crosses the city center, hindering the disconnection of living areas and urban development. Accordingly, the need for multi-dimensional development has been raised to secure land, and recently, interest has been increasing in connecting cities divided by the undergroundization of the Gyeongbu Line railway and making efficient use of land. In this study, the development type was analyzed through the case of multi-dimensional development of land, and the development direction for each three-dimensional development type was set based on the results of the multi-dimensional development of four areas (Sasang Station, Gupo Station, Gaya Station, and Busanjin Station). In addition, reflecting the regional characteristics of the target area and the ongoing urban regeneration project, we will propose a design plan for horizontal and vertical space utilization of the railway site through multi-dimensional development through the efficient land use.

Efficient seamless handoff over heterogeneous wireless networks

  • Lee Mi-jin;Ryu Sang-Hoon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 한국정보과학회 2005년도 가을 학술발표논문집 Vol.32 No.2 (1)
    • /
    • pp.268-270
    • /
    • 2005
  • Users using mobile terminal want to receive seamless service anywhere, anytime. In order to satisfy user's needs a communication between heterogeneous networks has to provide seamless service. Now a commercialized IMT-2000 is used with both WCDMA and CDMA together. Because asynchronous WCDMA and synchronous CDMA use different technology in their interface and traffic management, communication between the two networks can become disconnected. IP a mobile terminal swerves from the handoff area before handoff completion, packet loss and service disconnection will happened. In this paper, we propose a handoff scheme to provide seamless service, when mobile terminal moves from the WCDMA to the CDMA. And we prove that the proposed handoff scheme provide seamless service.

  • PDF

Prefetching Mechanism for Efficient Disconnected Operations in Mobile Computing Environment (이동 컴퓨팅 환경에서 효율적인 단절 연산을 위한 선인출 메카니즘)

  • 최창호;김명일;박상서;김성조
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 한국정보과학회 1998년도 가을 학술발표논문집 Vol.25 No.2 (3)
    • /
    • pp.538-585
    • /
    • 1998
  • 이동 컴퓨팅 환경에서 이동 호스트는 무선망을 통해 서버와 연결된 후에서야 데이터를 획득 및 처리할 수 있다. 그러나, 이동 호스트는 낮은 대역폭과 이로 인한 지연, 네트워크 단절(disconnection)과 같은 무선망의 특성으로 인하여 사용상에 많은 불편함과 비효율성이 발생하고 있는 실정이다. 특히, 이동 호스트가 네트워크 단절로 인해 서버에 접근이 불가능하고 작업에 필요한 데이터가 캐쉬에 없을 경우에는 작업 처리가 불가능하다. 본 논문에서는 이와 같은 문제점을 해결하기 위하여 이동 호스트가 미래에 작업할 데이터를 미리 인출해서 캐쉬에 저장하는 선인출 메카니즘을 제안하였다. 본 논문의 선인출 메카니즘을 기록기, 분석기, 선인출 목록 생성기, 그리고 비교기로 구성된다. 기록기와 분석기는 이동 호스트의 파일 참조 패턴들을 기반으로 프로파일을 생성하며, 선인출로 인한 성능 감소를 최소화하기 위해 선인출과 캐쉬 교체 전략을 통합한 선인출 메카니즘을 제시하였다.

  • PDF

Sag & Swell Detection by Phase Voltage Compensation in 3-Phase Unbalanced Grid (3상 불평형 계통에서의 상 전압 보상을 통한 Sag 및 Swell 검출)

  • Kim, Min-Gi;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.258-259
    • /
    • 2013
  • Load connection or disconnection makes instantaneous sag & swell in 3-phase grid. When unbalance state occurs, between sensed phase voltage and actual phase voltage may have discrepancy. It makes difficult to detect accurate sag & swell, so it is hard to satisfy the standard for switching ESS system to UPS mode. In this paper, we analyzed unbalanced 3-phase voltage, and compensated the actual sag & swell magnitude.

  • PDF

PERFORMANCE ANALYSES OF PATH RECOVERY ROUTING PROTOCOLS IN AD HOC NETWORKS

  • Wu, Mary;Kim, Chong-Gun
    • Journal of applied mathematics & informatics
    • /
    • 제26권1_2호
    • /
    • pp.235-249
    • /
    • 2008
  • On-demand routing protocol in ad hoc network is that establishes a route to a destination node only when it is required by a source node. But, it is necessary to reestablish a new route when an active route breaks down. The reconstruction process establishes another route by flooding messages from the source to the destination, cause not only heavy traffic but also long delays in route discovery. A good method for analyzing performance of protocols is important for deriving better systems. In this paper, we suggest the numerical formulas of a representative on-demand routing protocol AODV, ARMP, and RRAODV to estimate the performance of these routing protocols for analyzing the performance of these protocols. The proposed analytical models are very simple and straightforward. The results of analysis show good agreement with the results of computer simulations.

  • PDF

A study on the detection of poor contact and arcing fault using a fuzzy logic (퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구)

  • Kim, Hyun-Woo;Kim, In-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2007년도 추계학술논문발표회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF