• Title/Summary/Keyword: discharged water

Search Result 763, Processing Time 0.028 seconds

Full-scale Soil Washing and Non-discharged Washing Water Treatment Process of Soil Contaminated With Petroleum Hydrocarbon (현장규모의 유류오염 토양세척 및 무방류 세척 유출수 처리 공정)

  • Seo, Yong-Sik;Choi, Sang-Il;Kim, Jong-Min;Kim, Bo-Kyung;Kim, Sung-Gyoo;Park, Sang-Hean;Ju, Weon-Ha
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • A non-discharged system of sequentially physico-chemical water treatment was used to treat the contaminated water produced from washing system of soils according to full-scale soil washing. After washing the TPH contaminated soils, the remaining concentrations of COD$_{Mn}$, SS, and n-hexane were analyzed for each compartment to estimate the treatment efficiencies of non-discharged system. Three times of sampling events were conducted for 4 different compartments (sediment tank, flocculation tank, oil/water separator, and process-water tank). In addition, soil washing efficiencies and concentrations of each parameter (COD$_{Mn}$, SS, and n-hexane) for process-water tank were analyzed for about 8 months. As results, the average efficiency of soil washing was high to have 95.9%, regardless of the condition of TPH contamination level for soils, as well as the concentrations of COD$_{Mn}$, SS, and n-hexane in the process-water tank were below the regulation limits of the Water Environmental Conserveation Act. Accordingly, the full-scale washing treatment system in this study could make the washing water 100% recycled which lead the system to be environmentally-friendly and economical.

Oceanographic Environment Characteristics in Waters Adjacent to Fish Farm on Land (육상 양식장 인접해역의 해양학적 환경특성)

  • 조규대;이충일;김동선;양윤정
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.297-308
    • /
    • 2002
  • Field observations for research of oceanographic characteristics in waters adjacent to fish farm on land and water quality at area where water is supplied to fish farm and area where water is discharged from fish farm are carried out in coastal waters of Pyoson located in the southeastern region of Jeju Island in March, May, August and November of 2000. Semidiurnal tides to the northeast and southwest dominate. The mean velocities of current around neap tides and spring tides are 8.52cmㆍs$^{-1}$, 28.63cmㆍs$^{-1}$, respectively. The difference of temperature between area where water is supplied to fish farm and area where water is discharged from fish farm is about 0.6$^{\circ}C$. Seasonal variation range for temperature and salinity is 13.5$^{\circ}C$ and 3.5psu, individually. Concentrations of nitrate(NO$_3$$^{-}$), phosphate(PO$_4$$^{3-}$ ), silicate(SiO$_2$) and COD(chemical oxygen demand) are high in autumn. Particularly, concentrations of nitrate and COD in winter and spring at station where water is supplied to fish farm are higher than these at station where water is dischared from fish farm. However, concentration of phosphate and silicate at station where is supplied to fish farm in spring, summer and autumn is higher than that at station where water is dischared from fish farm. Water quality in the study area is grade 1 and this level is kept up in the whole year.

A Study on Groundwaters being Discharged into East Sea along the Shoreline of Southern of Southern Korean Peninsula (한반도 동해안 유출 지하수에 대한 연구)

  • Kim, Hyeong-Su;Kim, Seong-Ju
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.1
    • /
    • pp.71-84
    • /
    • 2001
  • A study was initiated to investigate whether the groundwaters being discharged into the sea could be used as a possible water resources. This paper presents a preliminary information about the groundwaters being discharged along the shoreline of East Sea. Major discharge sites were selected primarily on the basis of the informaion on surface temperatures of the sea. Hydrogeologic and geographic conditions were also considered in selecting the major discharge sites. The development possibility of the discharging groundwater were estimated roughly, considering populations, industries and social development compatibilities of the selected areas. Groundwater dams and linked usage with surface water were suggested as possible development methods for the groundwaters.. Based on this study, we selected about 60 sites as the major discharge areas and tentatively recommended 6 sites as optimal sites for development of groundwaters being discharged into the sea. However, detailed in-situ hydrogeologic surveys are required prior to the final decision.

  • PDF

Evaluation of the Effect of the Discharged Water from Bong Stream after Rainfall Events on the Bacteriological Water Quality in Gangjinman, Korea (강우 발생에 따른 남해군 봉천 방출수가 강진만 해역의 세균학적 수질에 미치는 영향 평가)

  • Park, Kun-Ba-Wui;Jo, Mi-Ra;Lee, Hee-Jung;Kwon, Ji-Young;Son, Kwang-Tae;Lee, Tae-Seek
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.6
    • /
    • pp.622-629
    • /
    • 2011
  • We investigated the effect of the discharged water from Bong Stream, which is located in the drainage area of Gangjinman area on the bacteriological water quality in the coastal area after rainfall events. Following 12.5 mm of rainfall, water discharged from Bong Stream had a very limited effect on bacteriological water quality in adjacent area and the affected area did not extend to the designated area. On the other hand, after 23 mm rainfall, the density of fecal coliform at stations located in the designated area was higher than at stations located in the adjacent area. The degree of bacteriological contamination at the surveyed stations in the coastal area after rainfall events did not show a relationship with distance from the shoreline. These results indicate that the direction of spread and the range of contaminants from the drainage area were affected by tides at the time of the survey. Therefore, a detailed survey of the effects of tides on the diffusion characteristics of the contaminants from Bong Stream is needed to establish a proper management plan for the surveyed area.

Hydraulics and water quality characteristics of flushing in distribution pipes (배수관 플러싱의 수리적 현상과 배출수의 수질 특성)

  • Ahn, Jae-Chan;Lee, Su-Won;Baek, Kwang-In;Choi, Young-June;Choi, Jae-Ho;Jeong, Eui-Sun;Park, Hyeon;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.93-103
    • /
    • 2008
  • This study was conducted to optimize a unidirectional flushing program in distribution pipes by analysis of water pressure, velocity, quality, and other parameters during flushing. As a result, correlation coefficient between flushed pipe length and the flushing duration was obtained $R^2=0.83$ and the equation $Y_{Time}=0.0571{\cdot}X_{Pipe\;length}+4.7648$ for 10 pipes. The averaged flushing velocity in the pipes, 1.1 m/s, was enough to remove loose deposits on the inner wall of the pipes. 3 of 92 water samples taken during flushing met the National Drinking Water Quality Standard for Fe and Mn, but not for Al. Turbidity less than 1 NTU is suggested for the appropriate criteria to finish flushing in pipes. The coefficient of determination ($R^2$) between turbidity and TSS was 0.95 and the equation was induced as $Y_{TSS}=1.2068{\cdot}X_{Turbidity}$. The amount of removed deposits could be estimated from the turbidity data of discharged water in field because turbidity and TSS in the discharged water is highly correlated.

Changes in bound water and microstructure during consolidation creep of Guilin red clay

  • Zhang, Dajin;Xiao, Guiyuan;Yin, Le;Xu, Guangli;Wang, Jian
    • Geomechanics and Engineering
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 2022
  • Creep of soils has a significant impact on mechanical properties. The one-dimensional consolidation creep test, thermal analysis test, scanning electron microscope (SEM) test, and mercury compression test were performed on Guilin red clay to study the changes in bound water and microstructure during the creep process of Guilin red clay. According to the results of the tests, only free and weakly bound water is discharged during the creep of Guilin red clay. When the consolidation pressure p is in the 12.5-400.0 kPa range, it is primarily the discharge of free water; when the consolidation pressure p is in the 800.0-1600.0 kPa range, the weakly bound water is converted to free water and discharged. After consolidation creep, the microstructure of soil changes from granular overhead contact structure to flat sheet-like stacking structure, with a decrease in the number of large and medium pores, an increase in the number of small and micro pores, and a decrease in the fractal dimension of pores. The creep process of red clay is the discharge of weakly bound water as well as the compression of large pores into small pores and the transition of soil particles from loose to dense.

Comparison of Water Characteristics of Cleaning Wastewater and Stormwater Runoff from Highways (고속도로 청소폐수와 노면유출수의 수질특성 비교)

  • Lee, Ju-Goang;Lee, Eui-Sang
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.169-176
    • /
    • 2007
  • The paved areas in nonpoint source are highly polluted landuses because of high imperviousness and pollutant mass emissions, such as sand, cereals, and dust from vehicle activities. Most of them in highways are collected by cleaning trucks or discharged to the adjacent soil and water system through the drain ditch in stormwater. Therefore, it is necessary to investigate the relationship between water concentration and total pollutant loadings from the paved areas. From the experiment, CODcr concentration of the cleaning wastewater was 17 times greater than that of the stormwater runoff. Also, concentrations of heavy metals (Cu, Fe, Zn) were 1.3 to 1.5 times higher when compared to the stormwater runoff. While total discharged loadings was insignificant in the cleaning wastewater. In conclusion, these results provide some evidence that the stormwater runoff may be managed carefully to the aspect of total pollutant loadings and the cleaning wastewater may be handled cautiously with the pollutant concentrations in highways.

Mortality Rates of Pathogen Indicator Microorganisms Discharged from Point and Non-point Sources in Urban Area (도시지역 점원, 비점원에서 유출되는 병원균 지표미생물의 사멸률)

  • Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1075-1081
    • /
    • 2006
  • In this research, mortality rates of pathogen indicator microorganisms discharged from various point sources and diffuse sources in urban area were measured. Water samples were taken at domestic sewer, combined sewer overflow, effluent from a wastewater treatment plant, urban river, and sediment of an urban river. Mortality rates of indicator microorganisms in domestic sewer estimated by assuming the first order kinetics at $20^{\circ}C$ were as follows: total coliform = 0.092/day, fecal coliform = 0.185/day, E. coli = 0.252/day, and fecal streptococci = 0.281/day. Sensitivity of mortality rates of total coliform on temperature was estimated as $K_{temp}=K_{20}{\times}1.162^{(temp-20)}$ for the range of $10-20^{\circ}C$. Mortality rates due to sunlight were measured as 1.22-1.59/day while mortality rate due to settling for 40 min were estimated as $9.21{\times}10^3-20.0{\times}10^3/day$.

A Study on Hydro Energy Development of Discharged Cooling Water at the Power Plant (발전소 온배수의 수력에너지 개발에 관한 연구)

  • Kang, K.S.;Lee, D.S.;Kim, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.813-818
    • /
    • 2005
  • Cooling seawater of thermal power plant which amounts about 5 cms per 100 MWe has hydro energy of about 3,000 kW at the thermal power plant complex, but this useful hydro energy has not been developed. Therefore, the feasibility study on hydro energy development of three power plants located in the southern and western coast of Korea was performed. Three target power plants are Samcheonpo, Boryeong and Hadong thermal power plant. The design head to discharge cooling water by gravity and the head caused by tidal level in the southwestern coastal area, could be used for the production of electric power. The various alternatives were studied and technical feasibility and economical efficiency were clearly proved.

  • PDF

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.